MPD A601ERU Single & dual output, 6w ultra-wide input range dc/dc converter Datasheet

A600ERU Series
Single & Dual Output, 6W
Ultra-Wide Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 6W Output Power
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• -40ºC to +85ºC Temp Range
• Compact DIP Case
• Single & Dual Outputs
• 1.0 MH MTBF
• Industry Standard Pin-Out
• Low, Low Cost
Parameter
Conditions
Input Voltage Range (See Note 1)
Min.
Typ.
Max.
24 VDC Input
9.0
24.0
36.0
48 VDC Input
18.0
48.0
72.0
Input Filter
Units
VDC
Capacitors
Reverse Polarity Input Current
Short Circuit Input Power
1.0
A
2,500
mW
Output
Parameter
Conditions
Typ.
Max.
Units
See Note 2
±1.0
±3.0
%
Dual Output , Balanced Loads
±3.0
Vin = Min to Max
±0.2
±0.5
%
Load Regulation
See Note 3
±0.5
±1.0
%
Noise (20 Hz - 300 kHz)
See Note 4
30
50
mV P - P
100
300
mV P - P
±0.01
±0.02
%/ºC
Typ.
Max.
Units
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Min.
Ripple (DC - 20 MHz)
Output Power Protection
%
120
Temperature Coefficient
Output Short Circuit
%
Continuous
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Switching Frequency
Min.
60 Seconds
1,500
500 VDC
1,000
VDC
M⍀
Single Output
300
Dual Output
250
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Min.
Ambient
Storage Temperature Range
Cooling
Max.
Units
-40
Typ.
+85
ºC
-55
+125
ºC
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
MicroPower Direct
Case Material
292 Page Street
Suite D
Stoughton, MA 02072
USA
Weight
Metal With Non-Conductive Base (UL94V-0)
0.49 Oz (14g)
Reliability Specifications
Parameter
Conditions
MTBF
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Typ.
Max.
1.0
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
Typ.
-0.7
50.0
48 VDC Input
-0.7
100.0
1.5 mm From Case For 10 Sec
Internal Power Dissipation
Max.
24 VDC Input
All Models
VDC
300
ºC
2,500
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
www.micropowerdirect.com
Model Selection Guide
Model
Number
Input
Current (mA)
Voltage (VDC)
Nominal
Range
24
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
48
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
18.0 - 72.0
Output
Fuse Rating
Reflected
Efficiency
Slow-Blow
Current
Ripple Voltage Current
(%, Typ)
(mA)
(VDC) (mA, Max) (mA, Min)
Full-Load No-Load Current
(mA, Typ)
A601ERU
A602ERU
A603ERU
A604ERU
A605ERU
A606ERU
A607ERU
A608ERU
A609ERU
A611ERU
A612ERU
A613ERU
A614ERU
A615ERU
A616ERU
A617ERU
A618ERU
A619ERU
278
312
304
304
301
312
304
298
294
137
156
152
147
145
156
152
149
147
20
20
20
20
20
20
20
20
20
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
±24.0
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
±24.0
Notes:
1. Exceeding the input range by a significant margin may damage the
units. For 24V input the input voltage should not exceed 40V; for 48V
models it should not exceed 80V.
2. Output accuracy for the negative output of dual output units is typically ±3% (±5% max.).
3. Output load regulation is specified for a load change of 10% to 100%. For 3.3V output units,
the load regulation is ±1.5% max.
4. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor
be placed from the +Vout pin to the -Vout pin for single output units and from each output to common
for dual output units.
5. These units should not be operated with a load under the specified minimum. Operation at
no-load will increase ripple significantly and may cause damage to the unit.
6. These converters are specified for operation without external components. However, in some
applications the addition of input/output capacitors will enhance stability and reduce output
ripple. Recommended capacitor values are:
Input
Vout
Capacitor
24 VDC 100 µF 3.3 VDC
48 VDC 100 µF
5 VDC
12 VDC
15 VDC
24 VDC
Vin
Output
Capacitor
100 µF
100 µF
100 µF
47 µF
47 µF
1,500
1,200
500
400
250
±600
±250
±200
±125
1,500
1,200
500
400
250
±600
±250
±200
±125
150.0
120.0
50.0
40.0
25.0
±60.0
±25.0
±20.0
±13.0
150.0
120.0
50.0
40.0
25.0
±60.0
±25.0
±20.0
±13.0
75
80
82
82
83
80
82
84
85
76
80
82
85
86
80
82
84
85
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
750
750
750
750
750
750
750
750
750
Derating Curve
Mechanical Dimensions
For applications requiring very low output noise levels, a simple LC filter
should be effective.
7. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Pin Connections
Pin
Single
2, 3
-Vin
Dual
-Vin
9
No Pin
Common
11
NC
-Vout
14
+Vout
+Vout
16
-Vout
Common
22, 23
+Vin
+Vin
NC: No Connection
MicroPower Direct
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]