RFSOLUTIONS DS-C2O-3 Easy to configure using sms commands. Datasheet

C2O
CALL ‘2
‘2’ OPEN USING YOUR MOBILE PHONE
Features
Easy to Configure using SMS
commands.
User Password Controlled
Relay Output rated 1.2KW
‘White List’ upto 100 Tel No’s
Signal Strength Indication
Internal Antenna
Waterproof Enclosure IP68
(Pressure Washer Proof)
Easy Operation
Access Control
User Calls C2O
Gates / Barriers / Doors
C2O Rejects call
Emergency Alarms
If valid C2O operates Output
Covert Systems
Remote Control
Ordering Information
PART No
C2O
SIM-O2
DS-C2O-2
Description
Call2Open Controller IP68
Contract Simcard SMS Only
Introduction
Call ‘2’ open (C2O) is a self contained access Control Solution which provides relay changover
contact output which can be used to operate gates / barriers etc.
When C2O receives a telephone call, if ‘White Mode’ is enabled It checks the caller’s telephone number with its own ‘White List’ and if valid, C2O operates its relay output momentarily.
Because C2O rejects the call there are no call charges incurred. (Using current call charging
structures).
The user can set upto 100 numbers on the white list, or set the C2O ‘Open’ to any caller
Typical Application Connection:
Normally the C2O output relay is wired across the switch which operates the Gate.
In order to connect the C2O across a standard push switch the relay COM and NO contacts
are wired in parallel to the users gate wall push switch.
Hardware Features
SIM card
The unit will accept SIM cards of most types subject to the following restrictions.
The SIM card should be inserted into C2O before applying power
Only 3 Volt SIM cards should be used.
The message memory of the SIM card should be clear before it is fitted to the C2O unit.
SIM cards that have been protected by means of a PIN (in a mobile phone) will not operate in
the unit.
Some types of pay-as-you-go SIM cards may require regular call activity (once every 3 - 6
months) to remain registered.
RF Solutions recommends O2 and Videophone SIM card and has carried out extensive testing
using the SIM cards we have for these two networks.
Problems have been identified with Orange SIM cards with this product.
No guarantee can be given for the operation of this product with any network except those
that have been tested by RF Solutions.
DS-C2O-3
Onboard LED’s Indication / Signal Strength
There are four LEDs on the circuit board. The Green LED indicates power is applied
The three Red LEDs indicate the status of C2O as below
During Initialisation After Power UP
RED LED Action
Description
LED’s illuminate alternately
Power-up initialisation (can take many seconds)
All LED’s flash together
No network found
Normal Operation
RED LED Action
Description
No LEDs
No signal
One LED on Steady
Low signal strength
Two LEDs on Steady
Medium signal strength
Three LEDs on Steady
High signal strength
When Transmitting or Receiving a TEXT
RED LED Action
Description
One LED Flashing
SMS being Received
TWO LED’s Flashing
SMS being Transmitted
Changeover Contact Outputs
Two relay outputs are provided on C2O and C2O-DIN, which provide a ‘switch’ output as below.
NC
COM
NO
NC
COM
NO
Relay Connections when
NOT Operating
Relay Connections when
OPERATING
Power Connections
The C2O unit can be powered from 12 or 24Vdc, a mains power supply is also available. Power
is connected via the Power Screw Terminal.
DS-C2O-3
Extending the Antenna
For low signal areas the internal antenna may be replaced with an external antenna. We offer
the following options.
Please Note:
Note Fitting the bulkhead connector in the enclosure will mean that the enclosure is
no longer IP68! Additional water sealing will be required if the unit is exposed.
CBACBA-UFLSMAUFLSMA-1
This cable connects onto the GSM Engine and provides a
bulkhead mounting SMA connector which may be fitted
to the enclosure, The external antenna below connect
directly.
Optional External Mount Gain Antenna
ANTANT-GSM5WM
Wall Mount Whip Antenna
Gain +5dB
Height ~250mm
3m Connecting Lead
OUTSIDEOUTSIDE-TSMA
Wall Mount Antenna
Gain +3dB
Dimensions 130 x 45 x 27mm
3m Connecting Lead
GSM20GSM20-ANT
Magnetic mount type Whip Antenna
Gain +3db
Height ~ 236 mm (including magnetic base)
Cable length 2.5m
DS-C2O-3
ANTANT-GSMPUKS
Rugged Low Profile ‘Puck’ Antenna
+2dBi Gain
3metres Cable
ANTANT-GSMSTUB4
Stubby Magnetic Mount
Gain: +4dBi
Height ~110mm
3m Connecting Lead
Waterproof Power Supply PSU12V1AINPSU12V1AIN-IP
Waterproof Resin Potted Unit (IP67)
Size 83 x 37 x 30mm
Input 100-240Vac Output 12Vdc 1A
Wall Fixing Lugs
Supplied with 3.3m lead
DS-C2O-3
Sending Text Commands
~ means a ‘space’ in the message.
Description
Command
Unit Password
This is the first command that must be sent within 5 minutes from intial power up.
The UPW can be any combination of letters/numbers from 5 to10 characters.
If for any reason the unit password is lost or miss-entered the user
must remove all power to the unit for 1 minute, when power is reapplied the user may then use the UPW command to set a new unit password.
(UPW)
Command Example:
Response:
UPW~Password123
UPW~OK
***NOTE THIS COMMAND IS CASE SENSITIVE!***
This command sets an activation time of the relay outputs.
Output delay time
(ODEL)
If ‘t’ is set to a value from 1 to 9 then this sets the number of seconds
for which the output remains on after an ON command.
If ‘t’ is set to ‘0’, then the output will Latch ‘ON’ permanently
Command Example:
Response:
Password123~ODEL1~7
UID~ODEL1~7~OK
The <UNIT ID> is an alphanumeric string consisting 4 to 10 characters.
Unit Identity
(UID)
This string of characters sets the ‘identity’ of the C2O unit, and is included in any response to identify the C2O unit to the user
Command:
Password123~UID~Identity7
Response:
Identity7~UID~OK
DS-C2O-3
Additional Commands for using the White List
Enable Call2Open Mode
from White List
(CTOWHL)
Turns ON White list check. When C2O receives a call, it checks the
Caller ID, If it is in the list it will activate the output, then reject the
call (so there will be no charge).
Command Example:
Password123~CTOWHL
Response:
UID~CTOWHL~OK
There is a max of 99 numbers that can be stored.
We advise you keep a separate list numbers their positions.
Add a number to the
White List
(WHL)
Command Example to add 1273898000 to location 4:
Password1234~WHL04~1273898000
Response: Password123~WHL04~1273898000~OK
Note: If your number has more than 23 digits, use the rightmost
ones. For example, if your number is 33446665555 you should program 3446665555.
Reports back a telephone number from the White list
Check a number in the
White List
(WHL?)
Command Example to report back the tel no in position 32:
Password123~WHL032?
Response:
Delete a number in the
White List
(WHLD)
Delete ALL numbers in
the White List
(WHLALLD)
Enable Call2Open Mode
from Any number
(CTOANY)
Command Example to delete the Tel no at loc’n 01:
Password123~WHL01D
Response:
Password123~WHL01~<0033612345678>~deleted
This command Deletes all telephone numbers within the White list
Command:
Password123~WHLALLD
Response
Password123~WHL~<ALL>~deleted
Turns OFF White list check. When C2O receives a call from ANY Tel
number, it will activate the output, then reject the call (so there will
be no charge).
Command Example: Password123~CTOANY
Response:
DS-C2O-3
Password123~WHL032~1273898000
UID~CTOANY~OK
C2O
Technical Specifications
Storage Temperature:
C2O Enclosure Rating
C2O Dimensions
-10 to +70o Celsius. Operating Temperature: 0 to +55o Celsius.
IP68
169 x 132 x 85mm
Electrical Characteristics
Min
Typical
Max
Dimension
Supply Voltage for 12Vdc
11
12.0
14
V
Supply Voltage for 24Vdc
23
24.0
26.0
V
35
200
44
370
100
1000
mA
mA
1
2
5
12
A
3
Supply Current for C2O:
Idle
Operating
Mains rated Relay Rating
(230Vac)
Notes
Notes
Refers to maximum supply current required with all components idle.
Refers to peak supply current required with all components operating. In practice internal reservoir capacitance
limits the instantaneous peak current to less than 500 mA.
The relay contacts in this unit are for functional switching only and must not be used for isolation purposes.
Disclaimer:
Whilst the information in this document is believed to be correct at the time of issue, R.F.Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or
completeness. No express or implied warranty or representation is given relating to the information contained in this document. R.F.Solutions Ltd reserves the right to make
changes and improvements to the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such information or
products for their own particular requirements or specification(s). R.F.Solutions Ltd shall not be liable for any loss or damage caused as a result of user’s own determination of
how to deploy or use R.F.Solutions Ltd’s products. Use of R.F.Solutions Ltd products or components in life support and/or safety applications is not authorised except with
express written approval. No licences are created, implicitly or otherwise, under any of R.F.Solutions Ltd’s intellectual property rights. Liability for loss or damage resulting or
caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where R.F.Solutions Ltd was aware of the
possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict R.F.Solutions Ltd’s liability for death or personal injury resulting from its negligence.
DS-C2O-2
Similar pages