XP Power D-60A 60w dual output switching power supply Datasheet

D-60
60W Dual Output Switching Power Supply
series
Features :
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
Fixed switching frequency at 54KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT
INPUT
D-60A
D-60B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
5V
12V
5V
24V
RATED CURRENT
4A
3A
3A
1.8A
CURRENT RANGE
0.3 ~ 6A
0.2 ~ 4A
0.3 ~ 6A
0.2 ~ 2.2A
RATED POWER
56W
58W
RIPPLE & NOISE (max.) Note.2 75mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
CH1 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
75mVp-p
CH1 : 4.75 ~ 5.5V
2.0%
6.0%
150mVp-p
5.0%
LINE REGULATION
0.5%
1.0%
0.5%
0.5%
LOAD REGULATION
0.5%
4.0%
0.5%
4.0%
SETUP, RISE TIME
300ms, 50ms / 230VAC
HOLD TIME (Typ.)
80ms/230VAC
VOLTAGE RANGE
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
73%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2A/115VAC
1A/230VAC
COLD START 20A/115VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVER LOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE
5V : 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
PROTECTION
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
800ms, 50ms / 115VAC at full load
10ms/115VAC at full load
120 ~ 370VDC
76%
40A/230VAC
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
0.03%/
, 10 ~ 95% RH
(0 ~ 50
) on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1012, UL60950, TUV EN60950 Approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
EMC
(Note 4)
OTHERS
NOTE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF
DIMENSION
301.2K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
PACKING
0.54Kg; 24pcs/13.8Kg/0.75CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:D-60-SPEC 2005-09-13
D-60
60W Dual Output Switching Power Supply
Mechanical Specification
Case No. 901
series
Unit:mm
3.5
7
152.5
1
3
84.5
4
8.2
5
2 -M
6
97
65
9.5
2
3
7
3 .5
4.5
78
24
159
150
22
38
3.5
M3
28.5
3 .5
3-
18
18.5
9
9
6.5
117
Terminal Pin. No Assignment
Pin No.
1
2
3
Assignment
AC/L
AC/N
FG
Pin No.
4
5
Assignment
DC OUTPUT +V2
DC OUTPUT +V1
6,7
DC OUTPUT COM
Output Derating
Static Characteristics (B)
Ta=25
100
OUTPUT VOLTAGE (V)
60
LOAD (%)
300
+5V
80
40
20
-10
-10
5.2
0
0
10
20
30
40
AMBIENT TEMPERATURE (
50
45
)
60
55
(VERTICAL)
(HORIZONTAL)
24
5.0
250
+24V
23
4.8
200
22
4.6
150
21
4.4
100
20
4.2
19
4.0
+24V
+5V
60
80
100
120
140
160
180
200
220
240
50
OUTPUT RIPPLE (mVp-p)
25
25
260
INPUT VOLTAGE (V) 60Hz
File Name:D-60-SPEC 2005-09-13
D-120
120W Dual Output Switching Power Supply
series
Features :
AC input range selected by switch
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 28KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT
D-120A
D-120B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
5V
12V
5V
24V
RATED CURRENT
12A
5A
6A
4A
CURRENT RANGE
2 ~ 12A
0.5 ~ 5A
2 ~ 10A
0.4 ~ 4A
RATED POWER
120W
126W
RIPPLE & NOISE (max.) Note.2 60mVp-p
120mVp-p
60mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
INPUT
6.0%
2.0%
7.0%
LINE REGULATION
0.5%
1.0%
0.5%
1.0%
LOAD REGULATION
0.5%
5.0%
0.5%
6.0%
SETUP, RISE, HOLD TIME
200ms, 50ms, 20ms at full load
VOLTAGE RANGE
88 ~ 132VAC/176 ~ 264VAC selected by switch
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
78%
AC CURRENT
INRUSH CURRENT (max.)
2.8A/115VAC
1.6A/230VAC
COLD START 35A
248 ~ 370VDC
80%
LEAKAGE CURRENT
<3.5mA / 240VAC
OVER LOAD
105 ~ 135% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
CH1:5.75 ~ 6.75VDC
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 ) on +5V output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
272.8K hrs min. MIL-HDBK-217F (25 )
MTBF
OTHERS
DIMENSION
PACKING
NOTE
199*110*50mm (L*W*H)
0.82Kg; 16pcs/14.2Kg/0.95CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:D-120-SPEC 2004-11-30
D-120
120W Dual Output Switching Power Supply
Mechanical Specification
Case No. 906
series
Unit:mm
192
5
172
3.5
6
100
1
9.5
2
3
97
110
4
5
6
8.2
5-M3
7
37
8
199
6
3.5
M
25
3-
50
20
12
2 4.5
1 6.5
3 .5
6.5
190.5
3
20
159
Terminal Pin. No Assignment
Pin No.
1
2
3
Assignment
AC/L
AC/N
FG
Pin No.
4
5,6
7,8
Assignment
DC OUTPUT +V2
DC OUTPUT COM
DC OUTPUT +V1
Derating Curve
Static Characteristics(B)
Ta=25
80
LOAD (%)
60
40
20
-10
-10
0
0
10
20
30
40
AMBIENT TEMPERATURE (
50
45
)
60
55
(VERTICAL)
(HORIZONTAL)
5.2
24
5.0
23
4.8
22
4.6
21
4.4
20
4.2
19
4.0
+24V
+5V
300
250
200
150
+24V
100
50
+5V
60
120
85
170
90
180
95
190
100
200
105
210
110
220
115
230
120
240
125
250
25
OUTPUT RIPPLE (mVp-p)
OUTPUT VOLTAGE (V)
100
25
130
260
INPUT VOLTAGE (V) 60Hz
File Name:D-120-SPEC 2004-11-30
Similar pages