PAIRUI ALR-50 Ac-dc converter Datasheet

AC-DC Converter
DIP-Package
ALR-50 Series, 50Watt
FEATURES:
Universal AC input range
Short circuit, and over current protections
Board in-line type installation
High voltage isolation
Metal case
Model
ALR50-5
ALR50-12
ALR50-24
ALR50-D5
ALR50-D12
ALR50-D24
Input voltage
(Vac)
Output voltage
(Vdc)
Output current
(mA)
Output power
(W)
5
10000
50
12
4200
50
24
2080
50
±5
±5000
50
±12
±2080
50
±24
±1040
50
85-265
Notes: Above models are default to metal case.
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
--
85
--
265
Vac
Input frequency
Fline
--
47
--
63
Hz
η
Full voltage, full load
--
82
--
%
Efficiency
Output
--
Vin=100-240Vac
--
1
--
%
Line regulation
Vout-line
Vin from 100Vac to 240Vac
--
0.2
--
%
Load regulation
Vout-load
20%-100% load
--
0.5
--
%
Vripple
--
--
--
120
mV
--
--
--
1
--
S
Output voltage Accuracy
Ripple
Turn-on delay time
www.pairuigroup.com
Page: 1 / 4
Date: 07/30/2015
*Subject to change without notice
AC-DC Converter
DIP-Package
ALR-50 Series, 50Watt
ELECTRICAL
Protection
Parameters
Symbols
Test Conditions / Comment
Over current
Continuous Automatic Recovery
Short circuit
Continuous Automatic Recovery
Min.
Typ.
Max.
Units
Environment
Storage
Ambient operating
temperature
Case temperature
Operating relative
humidity
MTBF
Tstorage
Humidity: 5% to 95% RH
-40
--
+105
℃
Ta
--
-25
--
+65
℃
Tc
--
--
--
+90
℃
Ha
Non condensing
10
--
90
%
TMTBF
--
--
--
200
kHrs
Dimension(LxWxH)
76.2x76.2x20mm
Weight
191g
Safety
Input-Output: 2500Vac≦1.5mA//1min
Isolation Voltage
Input-Case: 1500Vac≦1.5mA//1min
output-Case: 1500Vac≦1.5mA//1min
Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25
Vin = 100Vac to 240Vac.
www.pairuigroup.com
Page: 2 / 4
℃ and
Date: 07/30/2015
*Subject to change without notice
AC-DC Converter
DIP-Package
ALR-50 Series, 50Watt
MECHANICAL
CONNECTION
PIN #
SINGLE
DUAL
1
FG
FG
2
AC(N)
AC(N)
3
AC(L)
AC(L)
4
-S
-Vo2
5
TRIM
No Pin
6
+S
COM
7
GND
No Pin
8
+Vo
+Vo1
Note: Unit is mm(inch).
LAYOUT
ELECTRICAL CURVE
www.pairuigroup.com
Page: 3 / 4
Date: 07/30/2015
*Subject to change without notice
AC-DC Converter
DIP-Package
ALR-50 Series, 50Watt
NOTE
RECOMMENDED TEST AND APPLICATION CIRCUIT
EMC RECOMMENDED APPLICATION CIRCUIT
5VDC
12VDC
F1
T3.15A/250V
RT1
14D417K
NTC1
5D-14
R3
1MΩ/2W
L1
L=3-10mH,I=0.2-0.5A
CX1, CX2
0.15-3.3μF/300Vac
CY1, CY2
102K/400Vac
C3
1μF/50V
24VDC
C4
470uF/16V
120uF/25V
100uF/35V
Z1
P6KE6.8A
P6KE20A
P6KE33A
www.pairuigroup.com
Page: 4 / 4
Date: 07/30/2015
*Subject to change without notice
Similar pages