PAIRUI DBV2-0501 Dc-dc converter Datasheet

DC-DC Converter
SIP-Package
DBV-2 SERIES, 2WATT, REGULATED WITH 2:1 INPUT RANGE
FEATURES:
3 years warranty
1500Vdc isolation voltage
Wide (2:1) input voltage range
Regulated isolated twin output models
Operating temperature range -40°C to +85°C
Continuous short circuit protection
Model
Input voltage
(Vdc)
Output voltage
(Vdc)
Output current
(mA)
Min.
Max.
Efficiency
Typ.
DBV2-0501
5, 5
20
200
80%
DBV2-0502
9, 9
11
110
80%
12, 12
8.0
80
80%
DBV2-0504
15, 15
6.6
66
80%
DBV2-0505
24, 24
4.2
42
80%
DBV2-1201
5, 5
20
200
80%
DBV2-1202
9, 9
11
110
80%
12, 12
8.0
80
80%
DBV2-1204
15, 15
6.6
66
80%
DBV2-1205
24, 24
4.2
42
80%
DBV2-2401
5, 5
20
200
80%
DBV2-2402
9, 9
11
110
80%
12, 12
8.0
80
80%
DBV2-2404
15, 15
6.6
66
80%
DBV2-2405
24, 24
4.2
42
80%
DBV2-0503
DBV2-1203
DBV2-2403
5(4.5~9)
12(9~18)
24(18~36)
Notes: other input and output models may available on request.
ELECTRICAL
Line regulation
---
±0.2%
Load regulation
10% ~ 100% full load
±0.5%
Ripple and noise
---
100mVp-p max.
Isolation voltage
---
1500Vdc
Short circuit protection
---
Continuous short circuit protection
Operating temperature range
---
-40°C to +85°C
MTBF
---
35x105Hrs
Notes: All the data in this article are under test with “TA+25°C, humidity<75%, rated input and rated load”
mode.
www.pairuigroup.com
Page: 1/3
Date: 12/13/2013
DC-DC Converter
SIP-Package
DBV-2 SERIES, 2WATT, REGULATED WITH 2:1 INPUT RANGE
MECHANICAL
CONNECTION
PIN #
ISOLATED
TWIN
1
GND
2
+Vin
6
+Vo1
7
-Vo1
8
CS
9
-Vo2
10
+Vo2
Note:
* Unit is mm(inch).
TEMPERATURE PROFILE
CAPACITIVE LOADS SELECTION
Single Output
Cin
(Vdc)
(μF)
5
4.7-100
5
560
±5
270
12
4.7-100
9
470
±9
220
24
4.7-100
12
470
±12
220
-
-
15/24
330
±15/±24
150/100
www.pairuigroup.com
Voltage
Cout
Dual Output
Vin
(μF)
(Vdc)
Page: 2/3
Voltage
(Vdc)
Cout
(μF)
Date: 12/13/2013
DC-DC Converter
SIP-Package
DBV-2 SERIES, 2WATT, REGULATED WITH 2:1 INPUT RANGE
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
In order to ensure the efficiency and dependability of the module, the minimum specified load must be less than 10% of
rated load. If the output power is low, we recommend to add an external 10% loading resistor in parallel.
FUSE: depends on the actual input current;
TVS: depends on the actual input voltage;
Recommended capacitor:C1, C2, C5, C8 ,for C6,C7,C9, please check the capacitive load; C3,C4:2KV/1nF.
www.pairuigroup.com
Page: 3/3
Date: 12/13/2013
Similar pages