Panasonic ARS16Y4H 3 ghz microwave relays miniature size lineup includes 50/75î© type Datasheet

RS (ARS)
3 GHz MICROWAVE RELAYS
Miniature size
Lineup includes
50/75Ω type
3. Excellent high frequency
characteristics
• Impedance: 50Ω
(Standard PC board terminal)
Frequency
V. S. W. R. (Max.)
Insertion loss
(dB, Max.)
Isolation (dB, Min.)
RoHS compliant
to 900 MHz
1.20
to 3 GHz
1.40
0.10
0.35
60
35
• Impedance: 75Ω
(Standard PC board terminal)
FEATURES
1. Super miniature design
14 × 8.6 × 7.2 mm .551 × .339 × .283 inch
(standard PC board terminal)
60% OFF in volume
(Compared to
RK relay)
2. Lineup includes silent type.
(75Ω type only)
Operation noise (Unit: dB)
Frequency
V. S. W. R. (Max.)
Insertion loss
(dB, Max.)
Isolation (dB, Min.)
to 900 MHz
1.15
to 3 GHz
1.40
0.10
0.30
60
30
• Impedance: 50Ω
(Surface-mount terminal)
Frequency
V. S. W. R. (Max.)
Insertion loss
(dB, Max.)
Isolation (dB, Min.)
to 900 MHz
1.20
to 3 GHz
1.40
0.20
0.40
55
30
• Impedance: 75Ω
(Surface-mount terminal)
30
RS
(Silent type)
40
RE
50
Frequency
V. S. W. R. (Max.)
Insertion loss
(dB, Max.)
Isolation (dB, Min.)
to 900 MHz
1.20
to 3 GHz
1.50
0.20
0.50
55
30
RS RELAYS (ARS)
4. Lineup includes surface-mount
terminal type
E and Y layouts available.
5. Lineup includes reversed contact
type
Great design freedom is possible using
reversed contact type in which the
positions of the N.O. and N.C. contacts
are switched.
TYPICAL APPLICATIONS
1. Broadcasting and video equipment
markets
• Digital broadcasting equipment
• STB/tuner, etc.
2. Mobile phone base stations
3. Communications market
• Antenna switching
• All types of wireless devices
4. Measurement equipment market
• Spectrum analyzer and oscilloscope,
etc.
If you wish to use in applications with low
level loads or with high frequency
switching, please consult us.
RK
ORDERING INFORMATION
ARS
RS relays
Contact arrangement
1: Standard contact type (1 Form C)
3: Reversed contact type (1 Form C)
Operating function
0: Single side stable standard type (Impedance: 75Ω)
1: 1 coil latching type (Impedance: 75Ω)
2: 2 coil latching type (Impedance: 75Ω)
3: Single side stable silent type (Impedance: 75Ω)
4: Single side stable type (Impedance: 50Ω)
5: 1 coil latching type (Impedance: 50Ω)
6: 2 coil latching type (Impedance: 50Ω)
Nil: Standard PC board terminal
A: Surface-mount terminal, E layout
Y: Surface-mount terminal, Y layout
Coil voltage, DC
03: 3 V, 4H: 4.5 V, 09: 9 V, 12: 12 V, 24: 24 V (H=0.5)
Packing style
Nil: Carton packing (Standard PC board terminal only)
Tube packing (Surface-mount terminal only)
X: Tape and reel packing (picked from 2-pin side) (Surface-mount terminal only)
Z: Tape and reel packing (picked from 18-pin side) (Surface-mount terminal only)
ASCTB106E 201202-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
RS (ARS)
TYPES
1. Standard PC board terminal and standard contact type
Impedance
Nominal coil
voltage
50Ω
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
Impedance
Nominal coil
voltage
75Ω
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
Part No.
1 coil latching type
ARS1503
ARS154H
ARS1509
ARS1512
ARS1524
Single side stable type
ARS1403
ARS144H
ARS1409
ARS1412
ARS1424
2 coil latching type
ARS1603
ARS164H
ARS1609
ARS1612
ARS1624
Part No.
Single side stable type
ARS1003
ARS104H
ARS1009
ARS1012
ARS1024
Standard type
1 coil latching type
ARS1103
ARS114H
ARS1109
ARS1112
ARS1124
2 coil latching type
ARS1203
ARS124H
ARS1209
ARS1212
ARS1224
Silent type
Single side stable type
ARS1303
ARS134H
ARS1309
ARS1312
ARS1324
Standard packing: 50 pcs. in an inner package; 500 pcs. in an outer package
2. Standard PC board terminal and reversed contact type
Impedance
Nominal coil
voltage
50Ω
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
Impedance
Nominal coil
voltage
75Ω
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
Part No.
1 coil latching type
ARS3503
ARS354H
ARS3509
ARS3512
ARS3524
Single side stable type
ARS3403
ARS344H
ARS3409
ARS3412
ARS3424
2 coil latching type
ARS3603
ARS364H
ARS3609
ARS3612
ARS3624
Part No.
Single side stable type
ARS3003
ARS304H
ARS3009
ARS3012
ARS3024
Standard type
1 coil latching type
ARS3103
ARS314H
ARS3109
ARS3112
ARS3124
2 coil latching type
ARS3203
ARS324H
ARS3209
ARS3212
ARS3224
Silent type
Single side stable type
ARS3303
ARS334H
ARS3309
ARS3312
ARS3324
Standard packing: 50 pcs. in an inner package; 500 pcs. in an outer package
3. Surface-mount terminal and standard contact type, E layout
Impedance
50Ω
75Ω
Nominal coil
voltage
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
Single side stable type
ARS14A03
ARS14A4H
ARS14A09
ARS14A12
ARS14A24
ARS10A03
ARS10A4H
ARS10A09
ARS10A12
ARS10A24
Part No.
1 coil latching type
ARS15A03
ARS15A4H
ARS15A09
ARS15A12
ARS15A24
ARS11A03
ARS11A4H
ARS11A09
ARS11A12
ARS11A24
2 coil latching type
ARS16A03
ARS16A4H
ARS16A09
ARS16A12
ARS16A24
ARS12A03
ARS12A4H
ARS12A09
ARS12A12
ARS12A24
Standard packing: 40 pcs. in an inner package (tube); 1,000 pcs. in an outer package
Standard packing: 500 pcs. in an inner package (tape and reel); 1,000 pcs. in an outer package
Note: The box at the end of a part number shows where packing type is indicated. If there is no indication, tube packing will be used.
If “X” or “Z” is added, tape and reel packing will be used. Example: ARS14A03 (tube packing), ARS14A03X (tape and reel packing)
4. Surface-mount terminal and standard contact type, Y layout
Impedance
50Ω
75Ω
Nominal coil
voltage
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
Single side stable type
ARS14Y03
ARS14Y4H
ARS14Y09
ARS14Y12
ARS14Y24
ARS10Y03
ARS10Y4H
ARS10Y09
ARS10Y12
ARS10Y24
Part No.
1 coil latching type
ARS15Y03
ARS15Y4H
ARS15Y09
ARS15Y12
ARS15Y24
ARS11Y03
ARS11Y4H
ARS11Y09
ARS11Y12
ARS11Y24
2 coil latching type
ARS16Y03
ARS16Y4H
ARS16Y09
ARS16Y12
ARS16Y24
ARS12Y03
ARS12Y4H
ARS12Y09
ARS12Y12
ARS12Y24
Standard packing: 40 pcs. in an inner package (tube); 1,000 pcs. in an outer package
Standard packing: 500 pcs. in an inner package (tape and reel); 1,000 pcs. in an outer package
Note: The box at the end of a part number shows where packing type is indicated. If there is no indication, tube packing will be used.
If “X” or “Z” is added, tape and reel packing will be used. Example: ARS14Y03 (tube packing), ARS14Y03X (tape and reel packing)
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB106E 201202-T
RS (ARS)
5. Surface-mount terminal and reversed contact type, E layout
Impedance
Nominal coil
voltage
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
50Ω
75Ω
Part No.
1 coil latching type
ARS35A03
ARS35A4H
ARS35A09
ARS35A12
ARS35A24
ARS31A03
ARS31A4H
ARS31A09
ARS31A12
ARS31A24
Single side stable type
ARS34A03
ARS34A4H
ARS34A09
ARS34A12
ARS34A24
ARS30A03
ARS30A4H
ARS30A09
ARS30A12
ARS30A24
2 coil latching type
ARS36A03
ARS36A4H
ARS36A09
ARS36A12
ARS36A24
ARS32A03
ARS32A4H
ARS32A09
ARS32A12
ARS32A24
Standard packing: 40 pcs. in an inner package (tube); 1,000 pcs. in an outer package
Standard packing: 500 pcs. in an inner package (tape and reel); 1,000 pcs. in an outer package
Note: The box at the end of a part number shows where packing type is indicated. If there is no indication, tube packing will be used.
If “X” or “Z” is added, tape and reel packing will be used. Example: ARS34A03 (tube packing), ARS34A03X (tape and reel packing)
6. Surface-mount terminal and reversed contact type, Y layout
Impedance
Nominal coil
voltage
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
3 V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
50Ω
75Ω
Part No.
1 coil latching type
ARS35Y03
ARS35Y4H
ARS35Y09
ARS35Y12
ARS35Y24
ARS31Y03
ARS31Y4H
ARS31Y09
ARS31Y12
ARS31Y24
Single side stable type
ARS34Y03
ARS34Y4H
ARS34Y09
ARS34Y12
ARS34Y24
ARS30Y03
ARS30Y4H
ARS30Y09
ARS30Y12
ARS30Y24
2 coil latching type
ARS36Y03
ARS36Y4H
ARS36Y09
ARS36Y12
ARS36Y24
ARS32Y03
ARS32Y4H
ARS32Y09
ARS32Y12
ARS32Y24
Standard packing: 40 pcs. in an inner package (tube); 1,000 pcs. in an outer package
Standard packing: 500 pcs. in an inner package (tape and reel); 1,000 pcs. in an outer package
Note: The box at the end of a part number shows where packing type is indicated. If there is no indication, tube packing will be used.
If “X” or “Z” is added, tape and reel packing will be used. Example: ARS34Y03 (tube packing), ARS34Y03X (tape and reel packing)
RATING
1. Coil data
1) Single side stable type
Nominal coil
voltage
3
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
75%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
66.7 mA
45 Ω
44.4 mA
22.2 mA
16.7 mA
8.3 mA
101.3Ω
405 Ω
720 Ω
2,880 Ω
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 60°C 140°F)
200 mW
110%V or less of
nominal voltage
Nominal operating
power
Max. applied voltage
(at 60°C 140°F)
200 mW
110%V or less of
nominal voltage
Nominal operating
power
Max. applied voltage
(at 60°C 140°F)
400 mW
110%V or less of
nominal voltage
2) 1 coil latching type
Nominal coil
voltage
3
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
75%V or less of
nominal voltage
(Initial)
75%V or less of
nominal voltage
(Initial)
V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
66.7 mA
45 Ω
44.4 mA
22.2 mA
16.7 mA
8.3 mA
101.3Ω
405 Ω
720 Ω
2,880 Ω
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
3) 2 coil latching type
Nominal coil
voltage
3
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
75%V or less of
nominal voltage
(Initial)
75%V or less of
nominal voltage
(Initial)
V DC
4.5 V DC
9 V DC
12 V DC
24 V DC
ASCTB106E 201202-T
Panasonic Corporation
133.3 mA
22.5Ω
88.9 mA
44.4 mA
33.3 mA
16.7 mA
50.6Ω
202.5Ω
360 Ω
1,440 Ω
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
RS (ARS)
2. Specifications
Item
Arrangement
Contact material
Contact resistance (Initial)
Nominal switching capacity
Contact carrying power
Max. switching voltage
Max. switching current
Single side stable type
Nominal
operating
1 coil latching type
power
2 coil latching type
Contact
Rating
V.S.W.R.
High frequency
characteristics,
Impedance: 50Ω
(Initial)
Insertion loss (without D.U.T. board’s loss)
Isolation
V.S.W.R.
High frequency
characteristics,
Impedance: 75Ω
(Initial)
Insertion loss (without D.U.T. board’s loss)
Isolation
Insulation resistance (Initial)
Breakdown Between open contacts
voltage
Between contact and earth terminal
(Initial)
Between contact and coil
Electrical
characteristics
Temperature rise (at 20°C 68°F)
Operate time (at 20°C 68°F)
Release time (at 20°C 68°F)
Set time and Reset time (at 20°C 68°F)
Mechanical
characteristics
Operation noise*
Shock
resistance
Functional
Destructive
Vibration
resistance
Functional
Destructive
Standard type
Silent type (75Ω, PC board terminal type only)
Mechanical
life
Single side stable standard type
Single side stable silent type
Latching type
Expected life
50Ω type
Electrical life
75Ω type
Conditions
Conditions for operation, transport and storage
Unit weight
Specifications
1 Form C
Gold plating
Max. 100 mΩ (By voltage drop 10 V AC 10mA)
1W (at 3 GHz, Impedance: 50/75Ω, V.S.W.R.: Max. 1.4), 10 mA 24 V DC (resistive load)
Max. 10W (at 3GHz, Impedance: 50/75Ω, V.S.W.R.: Max. 1.4)
30 V DC
0.5 A DC
200mW
200mW
400mW
Max. 1.20/900MHz, Max. 1.40/3GHz (Standard PC board terminal)
Max. 1.20/900MHz, Max. 1.40/3GHz (Surface-mount terminal)
Max. 0.10dB/900MHz, Max. 0.35dB/3GHz (Standard PC board terminal)
Max. 0.20dB/900MHz, Max. 0.40dB/3GHz (Surface-mount terminal)
Min. 60dB/900MHz, Min. 35dB/3GHz (Standard PC board terminal)
Min. 55dB/900MHz, Min. 30dB/3GHz (Surface-mount terminal)
Max. 1.15/900MHz, Max. 1.40/3GHz (Standard PC board terminal)
Max. 1.20/900MHz, Max. 1.50/3GHz (Surface-mount terminal)
Max. 0.10dB/900MHz, Max. 0.30dB/3GHz (Standard PC board terminal)
Max. 0.20dB/900MHz, Max. 0.50dB/3GHz (Surface-mount terminal)
Min. 60dB/900MHz, Min. 30dB/3GHz (Standard PC board terminal)
Min. 55dB/900MHz, Min. 30dB/3GHz (Surface-mount terminal)
Min. 100MΩ (at 500V DC, Measurement at same location as “Breakdown voltage” section.)
500 Vrms for 1min. (Detection current: 10mA)
500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
Max. 60°C 140°F
(By resistive method, nominal voltage applied to the coil, contact carrying current: 10mA)
Max. 10 ms (Nominal voltage applied to the coil, excluding contact bounce time)
Max. 6 ms (Nominal voltage applied to the coil, excluding contact bounce time)
(without diode)
Max. 10 ms (Nominal voltage applied to the coil, excluding contact bounce time)
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms, detection time: 10µs)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms)
10 to 55 Hz at double amplitude of 3 mm (Detection time: 10µs)
10 to 55 Hz at double amplitude of 5 mm
Approx. 40dB
Approx. 30dB
Min. 5×106 (at 180 cpm)
Min. 106 (at 180 cpm)
Min. 106 (at 180 cpm)
Min. 106 (Standard PC board terminal), Min. 3×105 (Surface-mount terminal)
(10V DC 10mA resistive load)/Min. 3×105 (24V DC 10mA resistive load)
Min. 106 (Standard PC board terminal), Min. 3×105 (Surface-mount terminal)
(1W, at 3GHz, Impedance: 50Ω, V.S.W.R: Max. 1.4) (at 20 cpm)
Min. 3×105 (10mA 24V DC resistive load)
Min. 3×105 (1W, at 3GHz, Impedance: 75Ω, V.S.W.R: Max. 1.4) (at 20 cpm)
Ambient temperature: –40 to 70°C –40°F to 158°F
(Single side stable standard and Latching type)
Ambient temperature: –40 to 60°C –40°F to 140°F (Single side stable silent type)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Approx. 2 g .071 oz
* Measured the operation noise of the relay alone (with diodes at both ends of the coil) 30cm away from top side, by the A-weighted, FAST method while applying the rated
voltage.
(Reference) Operation noise of RK relay (existing model): Approx. 50dB
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB106E 201202-T
RS (ARS)
REFERENCE DATA
1.-(1) High frequency characteristics (Impedance: 50Ω, Standard PC board terminal)
Sample: ARS144H; Measuring method: Measured with Agilent Technologies network analyzer (E8363B). *For details see No. 7 under “NOTES”.
• V.S.W.R. characteristics
• Insertion loss characteristics
(without D.U.T. board’s loss)
2.0
• Isolation characteristics
0
0
Standard value
1.5
Reference value
Standard value
NC
Isolation, dB
Insertion loss, dB
V.S.W.R.
NO
0.5
Standard value
NO
50
NC
Reference value
NC
NO
1.0
0.3MHz
Reference value
900MHz
1.0
0.3MHz
3GHz
900MHz
100
0.3MHz
3GHz
900MHz
Frequency
Frequency
3GHz
Frequency
1.-(2) High frequency characteristics (Impedance: 75Ω, Standard PC board terminal)
Sample: ARS104H; Measuring method: Measured with Agilent Technologies network analyzer (E8363B). *For details see No. 7 under “NOTES”.
• V.S.W.R. characteristics
• Insertion loss characteristics
(without D.U.T. board’s loss)
2
• Isolation characteristics
0
0
NO
Standard value
1.5
Standard value
Standard value
NC
0.5
Isolation, dB
Insertion loss, dB
V.S.W.R.
Reference value
NC
50
NO
NO
Reference value
NC
1
0.3MHz
Reference value
900MHz
3GHz
1.0
0.3MHz
900MHz
100
0.3MHz
3GHz
900MHz
Frequency
Frequency
3GHz
Frequency
1.-(3) High frequency characteristics (Impedance: 50Ω, Surface-mount terminal)
Sample: ARS14A4H; Measuring method: Measured with Agilent Technologies network analyzer (E8363B). *For details see No. 7 under “NOTES”.
• V.S.W.R. characteristics
• Insertion loss characteristics
(without D.U.T. board’s loss)
2.0
• Isolation characteristics
0
0
Standard value
1.5
Standard value
NC
Isolation, dB
Insertion loss, dB
V.S.W.R.
NO
Reference value
Standard value
0.5
NO
50
NC
Reference value
NC
Reference value
NO
1
0.3MHz
900MHz
1.0
0.3MHz
3GHz
900MHz
100
0.3MHz
3GHz
900MHz
Frequency
Frequency
3GHz
Frequency
1.-(4) High frequency characteristics (Impedance: 75Ω, Surface-mount terminal)
Sample: ARS10A4H; Measuring method: Measured with Agilent Technologies network analyzer (E8363B). *For details see No. 7 under “NOTES”.
• V.S.W.R. characteristics
• Insertion loss characteristics
(without D.U.T. board’s loss)
2.0
• Isolation characteristics
0
0
Standard value
1.5
NO
Standard value
Standard value
Isolation, dB
Insertion loss, dB
V.S.W.R.
NC
Reference value
NO
0.5
NC
50
NO
Reference value
Reference value
NC
1.0
0.3MHz
900MHz
3GHz
1.0
0.3MHz
Frequency
ASCTB106E 201202-T
Panasonic Corporation
900MHz
3GHz
Frequency
Automation Controls Business Unit
100
0.3MHz
900MHz
3GHz
Frequency
industrial.panasonic.com/ac/e/
RS (ARS)
2.-(1) Operation noise distribution
When operated
Sample: ARS134H (single side stable silent type),
50 pcs.
Coil voltage: rated voltage applied (with diode)
Equipment setting: A weighted sound pressure level,
FAST.
Background noise: approx. 20 dB
Method of measurement: See figure below.
30
300mm
11.811inch
Quantity, n
Quantity, n
30
Microphone
Top of relay
When released
20
20
10
10
Acoustic absorption mat
0
20
Relay
30
40
0
20
50
30
Noise level, dB
40
50
Noise level, dB
2.-(2) Operation noise distribution
When operated
Sample: ARS104H (single side stable standard type),
50 pcs.
Coil voltage: rated voltage applied (with diode)
Equipment setting: A weighted sound pressure level,
FAST.
Background noise: approx. 20 dB
Method of measurement: See figure below.
300mm
11.811inch
Quantity, n
Quantity, n
Microphone
Top of relay
When released
30
30
20
20
10
10
Acoustic absorption mat
0
20
Relay
30
40
50
0
20
30
Noise level, dB
40
50
Noise level, dB
2.-(3) Operation noise distribution
When set and reset
Sample: ARS114H (latching type), 50 pcs.
Coil voltage: rated voltage applied (with diode)
Equipment setting: A weighted sound pressure level,
FAST.
Background noise: approx. 20 dB
Method of measurement: See figure below.
Quantity, n
30
Microphone
Top of relay
300mm
11.811inch
20
10
Acoustic absorption mat
0
20
Relay
30
40
50
Noise level, dB
The CAD data of the products with a
CAD Data
External dimensions
CAD Data
PC board pattern (Bottom view)
8.60
.339
3-2.50 +0.5
−0.1
3-.098 +.020
−.004
(Contact terminal)
14.00
.551
6.35
.250
1.40
.055
Lot No.
JAPAN
7.20
.283
The part numbers depend
on the type and voltage.
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
8-1.00 dia.
8-.039 dia.
2.54
.100
2 coil latching only
6.35
.250
DIMENSIONS (mm inch)
<Standard PC board terminal>
1. 50Ω type
3.50
.138
Tolerance: ±0.1 ±.004
2.54
.100
2 coil latching only
3-0.40×0.20
3-.016×.008
Stand off
3-0.45
3-.018
(0.60)
(.024)
2-0.60×0.20
2-.024×.008
Tolerance: ±0.3 ±.012
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB106E 201202-T
RS (ARS)
External dimensions
CAD Data
PC board pattern (Bottom view)
14.00
.551
7.20
.283
3.50
.138
2.54
.100
6.35
.250
2 coil latching only
6.35
.250
8.60
.339
JAPAN
3-2.50 +0.5
−0.1
3-.098 +.020
−.004
(Contact terminal)
Lot No.
The part numbers depend
on the type and voltage.
2.54
.100
3-0.90 dia.
3-.035 dia.
3-0.70 dia. Min.
3-.028 dia. Min.
0.80
.031
2. 75Ω type
1.40
.055
R0.40
1.80 R.016
.071
Tolerance: ±0.1 ±.004
2 coil latching only
3-0.40×0.20
3-.016×.008
Stand off
3-0.45
3-.018
2-1.40×0.20
2-.055×.008
(1.40)
(.055)
Tolerance: ±0.3 ±.012
Schematic (Bottom view)
1. Standard contact type
Single side stable type
(Deenergized condition)
–1
+5
2. Reversed contact type
1 coil latching type
(Reset condition)
+1
–5
2 coil latching type
(Reset condition)
1
4
–
10 9
NC
8
7
COM
6
NO
Direction indication
10 9
8
7
RESET COM
6
Direction indication
<Surface-mount terminal>
1. Impedance: 50Ω type
1) E layout
5
RESET
8
7
COM
10 9
6
NO
SET
External dimensions
3.2 .126
0.6 .024
8-0.4
8-.016
The part numbers
depend on the
type and voltage.
0.5
.020
3.2
.126
8
7
COM
6
10 9
NC
SET
Direction indication
Direction indication
10.16
.400
1 coil latching type
(Reset condition)
+1
–5
+ +
10 9
SET
Single side stable type
(Deenergized condition)
–1
+5
8
7
6
COM RESET
2 coil latching type
(Reset condition)
1
4
–
10 9
SET
8
7
6
COM RESET
Direction indication
Direction indication
Schematic (Top view)
<Standard contact type>
Single side stable type
(Deenergized condition)
3.2 .126
0.6 .024
3.2 .126
0.6 .024
NC COM NO
18 17 16 15 14 13 12 11 10
Lot No.
2
-
JAPAN
0.5 .020
0.5 .020
1.27 .050
4
6 7 8
+
1 coil latching type
(Reset condition)
2-coil latching type
(Reset condition)
RESET COM SET
18 17 16 15 14 13 12 11 10
RESET COM SET
18 17 16 15 14 13 12 11 10
2
+
Direction indication
4
6 7 8
-
2
-
4
6 7 8
++
Direction indication
Direction indication
1 coil latching type
(Reset condition)
2-coil latching type
(Reset condition)
SET COM RESET
18 17 16 15 14 13 12 11 10
SET COM RESET
18 17 16 15 14 13 12 11 10
<Reversed contact type>
10.16
.400
14.0 .551
0.15
.006
8.6
.339
0.15
.006
8.0
.315
Single side stable type
(Deenergized condition)
NO
COM NC
18 17 16 15 14 13 12 11 10
9.2
.362
11.2
.441
14.6
.575
2
-
4
6 7 8
+
Direction indication
2
+
4
6 7 8
-
Direction indication
2
-
4
Panasonic Corporation
Automation Controls Business Unit
6 7 8
++
Direction indication
Tolerance: ±0.3 ±.012
ASCTB106E 201202-T
5
+ +
industrial.panasonic.com/ac/e/
RS (ARS)
2) Y layout
External dimensions
10.16
.400
3.2 .126
0.6 .024
8-0.4
8-.016
The part numbers
depend on the
type and voltage.
0.5
0.6 .020
.024 3.2
.126
Schematic (Top view)
<Standard contact type>
Single side stable type
(Deenergized condition)
3.2 .126
3.2 .126
0.6 .024
NC
18 17 16 15
NO
13 12 11 10
1 coil latching type
(Reset condition)
RESET
18 17 16 15
SET
13 12 11 10
2-coil latching type
(Reset condition)
RESET
18 17 16 15
SET
13 12 11 10
Lot No.
2
-
JAPAN
0.5 .020
0.5 .020
1.27 .050
10.16
.400
14.0 .551
0.15
.006
Direction indication
8.6
.339
2
+
4 5 6 7 8
COM
2
-
4 5 6 7 8
COM + +
Direction indication
Direction indication
1 coil latching type
(Reset condition)
2-coil latching type
(Reset condition)
<Reversed contact type>
0.15
.006
Single side stable type
(Deenergized condition)
8.0
.315
NO
18 17 16 15
9.2
.362
11.2
.441
14.6
.575
4 56 7 8
+
COM
2
-
NC
13 12 11 10
4 5 6 7 8
+
COM
Direction indication
SET
18 17 16 15
2
+
RESET
13 12 11 10
4 5 6 7 8
COM
SET
18 17 16 15
2
-
RESET
13 12 11 10
4 5 6 7 8
COM + +
Direction indication
Direction indication
1 coil latching type
(Reset condition)
2-coil latching type
(Reset condition)
RESET COM SET
18 17 16 15 14 13 12 11 10
RESET COM SET
18 17 16 15 14 13 12 11 10
Tolerance: ±0.3 ±.012
2. Impedance: 75Ω type
1) E layout
External dimensions
10.16
.400
3.2 .126
0.6 .024
8-0.4
8-.016
The part numbers
depend on the
type and voltage.
0.5
.020
3.2
.126
Schematic (Top view)
<Standard contact type>
3.2 .126
0.6 .024
3.2 .126
0.6 .024
Single side stable type
(Deenergized condition)
NC COM NO
18 17 16 15 14 13 12 11 10
Lot No.
2
-
JAPAN
0.5 .020
0.5 .020
1.27 .050
10.16
.400
14.0 .551
0.15
.006
6 7 8
+
Direction indication
8.6
.339
2
+
4
6 7 8
-
2
-
4
6 7 8
++
Direction indication
Direction indication
1 coil latching type
(Reset condition)
2-coil latching type
(Reset condition)
SET COM RESET
18 17 16 15 14 13 12 11 10
SET COM RESET
18 17 16 15 14 13 12 11 10
<Reversed contact type>
0.15
.006
Single side stable type
(Deenergized condition)
8.0
.315
NO
COM NC
18 17 16 15 14 13 12 11 10
9.2
.362
11.2
.441
14.6
.575
4
2
-
4
6 7 8
+
Direction indication
2
+
4
6 7 8
-
2
-
4
6 7 8
++
Direction indication
Direction indication
1 coil latching type
(Reset condition)
2-coil latching type
(Reset condition)
Tolerance: ±0.3 ±.012
2) Y layout
External dimensions
10.16
.400
3.2 .126
0.6 .024
8-0.4
8-.016
The part numbers
depend on the
type and voltage.
0.5
0.6 .020
.024 3.2
.126
Schematic (Top view)
<Standard contact type>
Single side stable type
(Deenergized condition)
3.2 .126
3.2 .126
0.6 .024
NC
18 17 16 15
NO
13 12 11 10
RESET
18 17 16 15
SET
13 12 11 10
RESET
18 17 16 15
SET
13 12 11 10
Lot No.
2
-
JAPAN
0.5 .020
0.5 .020
1.27 .050
10.16
.400
14.0 .551
0.15
.006
Direction indication
8.6
.339
2
+
4 5 6 7 8
COM
2
-
4 5 6 7 8
COM + +
Direction indication
Direction indication
1 coil latching type
(Reset condition)
2-coil latching type
(Reset condition)
<Reversed contact type>
0.15
.006
8.0
.315
14.6
.575
4 56 7 8
+
COM
9.2
.362
11.2
.441
Single side stable type
(Deenergized condition)
NO
18 17 16 15
2
-
NC
13 12 11 10
4 5 6 7 8
+
COM
Direction indication
SET
18 17 16 15
2
+
RESET
13 12 11 10
4 5 6 7 8
COM
Direction indication
SET
18 17 16 15
2
-
RESET
13 12 11 10
4 5 6 7 8
COM + +
Direction indication
Tolerance: ±0.3 ±.012
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB106E 201202-T
RS (ARS)
NOTES
1. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be
rectangular. If it includes ripple, the ripple
factor should be less than 5%.
However, check it with the actual circuit
since the characteristics may be slightly
different. The nominal operating voltage
should be applied to the coil for more
than 30 ms to set/reset the latching type
relay.
2. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or
malfunction.
3. External magnetic field
Since RS relays are highly sensitive
polarized relays, their characteristics will
be affected by a strong external magnetic
field. Avoid using the relay under that
condition.
4. Cleaning
For automatic cleaning, the boiling
method is recommended. Avoid
ultrasonic cleaning which subjects the
relays to high frequency vibrations, which
may cause the contacts to stick.
It is recommended that alcoholic solvents
be used.
5. Conditions for operation, transport
and storage conditions
1) Temperature
• Single side stable standard and latching
type: –40 to 70°C –40 to 158°F
• Single side stable silent type:
–40 to 60°C –40 to 140°F
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage:
Single side stable standard
and latching type
Humidity, %R.H.
85
Tolerance range
(Avoid freezing
when used at
temperatures
lower than
0°C 32°F)
5
-40
-40
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
0
70
32
158
Temperature, °C °F
ASCTB106E 201202-T
Single side stable silent type
Humidity, %R.H.
85
Tolerance range
(Avoid freezing
when used at
temperatures
lower than
0°C 32°F)
5
-40
-40
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
A
0
60
32
140
Temperature, °C °F
4) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
5) Freezing
Condensation or other moisture may
freeze on the relay when the temperature
is lower than 0°C 32°F. This causes
problems such as sticking of movable
parts or operational time lags.
6) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
7) Storage requirements
Since the relay is sensitive to humidity,
the surface-mount type is packaged with
tightly sealed anti-humidity packaging.
However, when storing, please be careful
of the following.
(1) Please use promptly once the antihumidity pack is opened.
If relays are left as is after unpacking,
they will absorb moisture which will result
in loss of air tightness as a result of case
expansion due to thermal stress when
reflow soldering during the mounting
process. (within one day, 30°C and
60%R.H or less)
(2) When storing for a log period after
opening the anti-humidity pack, storage
in anti-humidity packaging with an antihumidity bag to which silica gel has been
added, is recommended.
*Furthermore, if the relay is solder
mounted when it has been subjected to
excessive humidity, cracks and leaks can
occur. Be sure to mount the relay under
the required mounting conditions.
6. Soldering
1) Please meet the following conditions if
this relay is to be automatically soldered.
(1) Preheating: Max. 120°C 248°F
(terminal solder surface) for max. 120
seconds
(2) Soldering: Max. 260±5°C 500±9°F for
max. 6 seconds
Panasonic Corporation
*Relays are influenced by the type of PC
board used. Please confirm with the
actual PC board you plan to use.
*Please avoid reflow soldering.
2) Surface-mount terminal
In case of automatic soldering, the
following conditions should be observed
(1) Position of measuring temperature
Automation Controls Business Unit
A: Surface of PC board where relay is mounted.
(2) IR (infrared reflow) soldering method
T3
T1=150 to 180°C
T2
T2=230°C and higher
T1
T3=250°C max.
t1=60s to 120s
t2=within 30s
t1
t2
• Mounting cautions
Rise in relay temperature depends
greatly on the component mix on a given
PC board and the heating method of the
reflow equipment. Therefore, please test
beforehand using actual equipment to
ensure that the temperature where the
relay terminals are soldered and the
temperature at the top of the relay case
are within the conditions given above.
3) Please meet the following conditions if
this relay is to be soldered by hand.
(1) 260°C 500°F for max. 10 seconds
(2) 350°C 662°F for max. 3 seconds
The effect on the relay depends on the
actual substrate used. Please verify the
substrate to be used.
(3) Avoid ultrasonic cleaning. Doing so
will adversely affect relay characteristics.
Please use alcohol-based cleaning
solvents when cleaning relays.
7. Tape and reel packing
1) Tape dimensions
X type
1.5 +0.1
0 dia.
2.0 1.75 8.3
.059 +.004
dia.
0
16.0 .079 .069 .327
12.0 .630 4.0
RS relay
0.4
.472
.157
.016
11.5
.453
8.6
.339
15.00
.591
24.0±0.3
.945±.012
Tape coming out direction
Relay polarity bar
Z type
(General tolerance: ±0.1 ±.004)
2) Dimensions of plastic reel
21 ±0.8 dia.
.827 ±.031dia.
380 ±2 dia.
14.961 ±.079 dia.
80 ±1 dia.
3.150 ±.039 dia.
2.0 ±0.5
.079±.020
13 ±0.2 dia.
.512 ±.008dia. 24.4+2.0
0
.961+.079
0
2.0 ±0.2
.079 ±.008
industrial.panasonic.com/ac/e/
RS (ARS)
1
Network
analyzer
2
PORT2
Agilent
1
2.50
.098 1.80
.071
2
Te c h n o l o g i e s
PORT1
6.05
.238
No.
Product name
Contents
1
Agilent
85130-60011
Adapter
2.4mm-3.5mm female
.095inch-.138inch female
2
SUHNER
SUCOFLEX104
Cable
3.5mm-3.5mm male
.138inch-.138inch male
After calibration, connect the D.U.T.
board and measure. However,
connectors other than those for
measurement should be connected with
a 50Ω termination resistor.
<Standard PC board terminal>
PC board
Dimensions (mm inch)
3-R 0.90
3-R .35
1.80
.071
13.00
.512 2.80
.110
6.35
.250
4.20
.165
3-R 1.40
3-R .055
5.08
.200
8-1.00 dia.
8-.039 dia.
(Through hole)
5-2.00 dia.
5-.079 dia.
3-1.00 dia.
3-.039 dia.
15.15 22.00
.596 .866
15.95
.628
1.80
.071
1.80
2.50 .071
.098 2.80
.110
1.27
.050
3-0.70 dia.
3-.028 dia.
(Through hole)
2.54
.100
20.00
.787
10.16
.400
0.90
.035
13.00
.512
3-0.55 dia.
3-.022 dia.
6.35
.250
4.90
.193
4.20
.165
3-1.50 dia.
3-.059 dia.
PC board for correction
Dimensions (mm inch)
<Surface-mount terminal and
E layout>
PC board
Dimensions (mm inch)
2.80
1.80 .110
.071
9.12
.359
Material: Glass PTFE double-sided
through hole PC board R-4737
(Panasonic Corporation)
Board thickness: t = 0.8 mm .031 inch
Copper plating: 18 µm
Connector (SMA type receptacle)
Product name: 01K1808-00 (Waka
Manufacturing Co., Ltd.)
Insertion loss compensation
The insertion loss of relay itself is given
by subtracting the insertion loss of
shortcircuit the Com and the NC (or NO).
(signal path and two connectors)
2) 75Ω type
1
5-1.40 dia.
5-.055 dia.
5.08
.200
0.80
.031
3-3.00 dia.
3-.118 dia.
2.50 3.70
.098 .146
2.80
.110
Connect connectors 1 and 2 respectively
to PORT 1 and PORT 2. Perform
calibration using the 3.5 mm calibration
kit (HP85052B).
1.78
.070
R0.40
R.016
20.00
.787
10.16
.400
E8363B
20.00
.787
10.16
.400
<Standard PC board terminal>
PC board
Dimensions (mm inch)
<Surface-mount terminal and
Y layout>
PC board
Dimensions (mm inch)
8. Measuring method
1) 50Ω type
2.50
.098 0.80
.031
20.00
.787
10.16
.400
2.80
.110 2.50
0.80 .098
.031
4.70
.185 7.75
.305 24.00
.945
16.15
.636
2.80
.110
0.80
.031
1.27
.050
<Surface-mount terminal and
Y layout>
PC board
Dimensions (mm inch)
2.50
.098 0.80
.031
2
20.00
.787
10.16
.400
2.50 4.70
.098 .185
PORT2
2.54
.100
2.50
.098 1.80
.071
2.80
.110
20.00
.787
10.16
.400
1
2
Technologies
E8363B
No.
1
15.15
.596
22.00
.866
1.27
.050
PORT1
Connect connectors 1 and 2 respectively
to PORT 1 and PORT 2. Perform
calibration using the 3.5 mm calibration
kit (HP85039B).
2.80
.110 2.50
1.80 .098
.071
3.70
.146 6.05
.238
1.80
.071
0.80
.031
Agilent
<Surface-mount terminal and
E layout>
PC board
Dimensions (mm inch)
7.75
.305 16.25
.640
16.15 24.00
.636 .945
2.80
.110
Network
analyzer
Product name
85134-60003
2
11852B
2
85039-60011
Contents
Test port cable
Conversion adapter;
50Ω N type (female) to
75Ω N type (male)
Conversion adapter;
75Ω N type (female) to
75Ω F type (male)
After calibration, connect the D.U.T.
board and measure. However,
connectors other than those for
measurement should be connected with
a 75Ω termination resistor.
Panasonic Corporation
Automation Controls Business Unit
0.80
2.50 .031
.098 2.80
.110
1.27
.050
PC board for correction
Dimensions (mm inch)
4.90
.193
0.90
.035
9.12
.359
Material: Glass PTFE double-sided
through hole PC board R-4737
(Panasonic Corporation)
Board thickness: t = 0.8 mm .031 inch
Copper plating: 18µm
Connector (F type receptacle)
Product name: C05-0236 (Komine
Musen Electric Corporation)
industrial.panasonic.com/ac/e/
ASCTB106E 201202-T
RS (ARS)
Insertion loss compensation
The insertion loss of relay itself is given
by subtracting the insertion loss of
shortcircuit the COM and the NC (or NO).
(signal path and two connectors)
9. Others
1) The switching lifetime is defined under
the standard test condition specified in
the JIS* C 5442 standard (temperature
15 to 35°C 59 to 95°F, humidity 25 to
75%). Check this with the real device as it
is affected by coil driving circuit, load
type, activation frequency, activation
phase, ambient conditions and other
factors.
Also, be especially careful of loads such
as those listed below.
• When used for AC load-operating and
the operating phase is synchronous,
rocking and fusing can easily occur due
to contact shifting.
• When high-frequency opening and
closing of the relay is performed with a
load that causes arcs at the contacts,
nitrogen and oxygen in the air is fused by
the arc energy and HNO3 is formed. This
can corrode metal materials.
ASCTB106E 201202-T
Three countermeasures for these are
listed here.
(1) Incorporate an arc-extinguishing
circuit.
(2) Lower the operating frequency
(3) Lower the ambient humidity
2) Use the relay within specifications
such as coil rating, contact rating and on/
off service life. If used beyond limits, the
relay may overheat, generate smoke or
catch fire.
3) Be careful not to drop the relay. If
accidentally dropped, carefully check its
appearance and characteristics before
use.
4) Be careful to wire the relay correctly.
Otherwise, malfunction, overheat, fire or
other trouble may occur.
5) If a relay stays on in a circuit for many
months or years at a time without being
activated, circuit design should be
reviewed so that the relay can remain
non-excited. A coil that receives current
all the time heats, which degrades
insulation earlier than expected. A
latching type relay is recommended for
such circuits.
Panasonic Corporation
Automation Controls Business Unit
6) To ensure accurate operation of the
latching type amidst surrounding
temperature changes and other factors
that might affect the set and reset pulse
times, we recommend a coil impress set
and reset pulse width of at least 30 ms at
the rated operation voltage.
7) The latching type relay is shipped in
the reset position. But jolts during
transport or impacts during installation
can change the reset position. It is,
therefore, advisable to build a circuit in
which the relay can be initialized (set and
reset) just after turning on the power.
8) If silicone materials (e.g., silicone
rubbers, silicone oils, silicone coating
agents, silicone sealers) are used in the
vicinity of the relay, the gas emitted from
the silicone may adhere to the contacts of
the relay during opening and closing and
lead to improper contact. If this is the
case, use a material other than silicone.
For general cautions for use, please
refer to the “General Application
Guidelines”.
industrial.panasonic.com/ac/e/
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panasonic:
ARS1009 ARS1309 ARS1412 ARS144H ARS1512 ARS154H ARS1612 ARS164H ARS304H ARS1112
ARS1024 ARS1124 ARS1224 ARS1312 ARS1212 ARS1324 ARS104H ARS1012 ARS114H ARS134H
ARS124H ARS10A03 ARS10A03X ARS10A03Z ARS10Y03X ARS10Y03Z ARS10Y12 ARS10Y4H ARS11Y03X
ARS11Y03Z ARS12A03 ARS12Y03 ARS15A03 ARS15Y03 ARS15Y4H ARS16A03 ARS16A03X ARS16Y4H
ARS30A03 ARS30A03X ARS30A03Z ARS30Y03 ARS30Y03X ARS30Y03Z ARS34A03 ARS34A4H ARS34Y03
ARS34Y4H ARS35Y4H