Jumbo-LED ELJ-810-629 15.11.2007 rev. 05 Radiation Type Technology Case Infrared 4W AlGaAs/GaAlAs Plastic lens, metal case High-power infrared-LED in an aluminium case with thread socket, for easy handling and heat sink mounting 1,5 Ø11 Ø1,7 Ø16 Ø12,5 Description 4,5 5,08 7,9 Outline: 2 H = 12.4 mm (± 0.5) Medical appliances, remote control and optical communications, light barriers, measurement systems 8 D = 16 mm (± 0.5) 13 Thread M10 1 2 Applications Pin 1 – cathode Pin 2 – anode M10 Absolute Maximum Ratings at Tamb = 25°C, on heat sink (S ≥ 200 cm²), unless otherwise specified Test сonditions Symbol Value Unit on heat sink IF 1.1 A tp≤10 µs, f≤500 Hz IFM 2,0 A Power dissipation on heat sink P 4 W Operating temperature range on heat sink Tamb -25 to +100 °C Storage temperature range on heat sink Tstg -25 to +100 °C Junction temperature on heat sink Tj 100 °C Typ Max Unit Parameter DC forward current Peak forward current Electrical Characteristics Tamb = 25°C, unless otherwise specified Parameter Test conditions Symbol Min Forward voltage IF = 350 mA VF 1.6 2.0 V Forward voltage* IF = 1000 mA VF 2.0 2.6 V Switching time IF = 350 mA tr , t f 75 ns Reverse voltage IR = 100 µA VR 10 K/W Thermal resistance junction-case *only recommended on optimal heat sink RthJC 5 We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 1 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-810-629 15.11.2007 rev. 05 Optical Characteristics at Tamb = 25°C, on heat sink (S ≥ 200 cm²), unless otherwise specified Test Parameter Symbol Min conditions Typ Max Unit Radiant power IF = 350 mA Φe Radiant power* IF = 1000 mA Φe Radiant intensity IF = 350 mA Ιe Radiant intensity* IF = 1000 mA Ιe Peak wavelength IF = 350 mA λp Spectral bandwidth at 50% IF = 350 mA ∆λ0,5 30 nm Viewing angle IF = 350 mA ϕ 17 deg 40 300 800 50 mW 125 mW 600 mW/sr 1650 mW/sr 810 820 nm *only recommended on optimal heat sink Note: All measurements carried out with EPIGAP equipment, on blank aluminium heat sink, S = 180 cm², passive cooling. Measurement results and curve characteristics obtained with other heat sinks may differ. Typical wavelength shift vs. forward current (rel. to λP @ IF = 350 mA) Wavelength shift (nm) 15 10 5 0 -5 0 200 400 600 800 1000 1200 1400 IF (mA) We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 2 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-810-629 15.11.2007 rev. 05 Radiant power vs. forward current (typical) normalized to Φe @ IF = 350 mA 4 ΦE (rel.) 3 2 1 0 0 200 400 600 800 1000 1200 1400 IF (mA) Forward current vs. forward voltage (typical) 1400 1200 IF (mA) 1000 800 600 400 200 0 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 UF (V) We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 3 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-810-629 15.11.2007 rev. 05 Ambient Temperature vs. maximal forward current 1.4 Max. forward current (A) 1.2 1.0 0.8 0.6 0.4 0.2 0.0 0 25 50 75 100 Ambient Temperature (°C) Remarks concerning optical radiation safety* At low forward current (<100 mA), and continuous operation, this LED may be classified as LED product Class 1 , according to standard IEC 60825-1:A2. Class 1 products are safe to eyes and skin under reasonably predictable conditions. This implicates a direct observation of the light beam by means of optical instruments. When driven with higher continuous forward current, (up to 800 mA), this product should be classified as LED product Class 1M , according to standard IEC 60825-1:A2. Class 1M products are safe to eyes and skin under normal conditions, including when users view the light beam directly. Class 1M products produce either a highly divergent beam or a large diameter beam. Therefore only a small part of the whole light beam can enter the eye. However, such optical products can be harmful to the retina if the beam is viewed using magnifying optical instruments. Therefore, users should not incorporate optics that could concentrate the output into the eyes. If intended to operate at very high continuous current (>0.8 A), this product has to be (potentially) classified as Class 3B LED. Class 3B LEDs may have sufficient power to cause an eye injury, both from the direct beam and from reflections,so these products are therefore considered hazardous to the eye. However, the extent and severity of any eye injury arising from an exposure to the light beam of a Class 3B product will depend upon several factors including the radiant power entering the eye and the duration of the exposure. Nontheless, adequate precautions should be taken to avoid direct or indirect viewing into the beam. *Note: Safety classification of an optical component mainly depends on the intended application and the way the component is being used. Furthermore, all statements made to classification are based on calculations and are only valid for this LED "as it is", and at continuous operation. Using pulsed current or altering the light beam with additional optics may lead to different safety classifications. Therefore these remarks should be taken as recommendation and guideline only. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 4 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-810-629 15.11.2007 rev. 05 Handling precautions To prevent damage to the LED during soldering and assembly, following precautions have to be taken into account. a) The bending point of the lead frame should be located at least 2.5 mm away from the body. b) While bending, the base of the lead frame has to be fixed with radio pliers or similar. c) To ensure an adequate strain relief, the lead frames have to be firmly fixed during soldering. d) Avoid any torsion or tensile loading of the lead frames, especially when they have been heated after being soldered. e) LEDs are static sensitive devices, so adequate handling precautions have to be taken, e.g. wearing grounding wrist straps. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 5 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545