Arch ANC50-24S Ac -dc powermodule Datasheet

VER : B_8
update : 2015.11.16
AC-DC Power Module
ANC50
SERIES
50 Watts
KEY FEATURES
 Switching Power Module for PCB Mountable
 Fully Encapsulated Plastic Case
 Regulated Output and Low Ripple and Noise
 Small Size as ANC 15Watt with 50Watt Higher Power
 CE, UL Approval
 3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
( Single Output )
Max Output Wattage (W)
Voltage
Input
Output
Protection
Isolation
Environment
Physical
ANC50-5S
40W
ANC50-12S
50W
ANC50-15S
50W
ANC50-24S
50W
ANC50-48S
50W
90-264 VAC or 120-370 VDC
Frequency (Hz)
47-63 Hz
Current (Full load)
1000 mA max. (115 VAC) / 600 mA max. (230 VAC)
Inrush Current (<2ms)
40 A max. (115 VAC) / 60 A max. (230 VAC)
Leakage Current
0.25 mA max.
External Fuse (recommend)
3.15 A slow blow type
Voltage (V.DC.)
5V
Voltage Accuracy
±2%
12V
15V
24V
48V
4167
3333
2083
1040
Current (mA) max
8000
Line Regulation (LL-HL) (typ.)
±1%
Load Regulation (0-100%) (typ.)
±1%
Minimum Load
0%
Maximum Capacitive Load
10000 uF
3500 uF
3000 uF
2200 uF
330uF
Ripple & Noise
120mV
120mV
150mV
240mV
480mV
Efficiency (at 230 VAC)
86%
90%
87%
88%
89%
Hold-up Time
10 ms min.
Switching Frequency (typ.) ( at 230 VAC )
65 kHz
Over Power Protection
Hiccup technique, auto-recovery
Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
Input-Output (V.AC)
3000V
Input-FG (V.AC)
1500V
Output-FG (V.AC)
500V
Operating Temperature
-40°C…+70°C (with derating)
Storage Temperature
-40°C…+85°C
Temperature Coefficient
±0.02%/°C
Humidity
95% RH
MTBF
>300,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
2.91 x 2.13 x 0.86 Inches
Case Material
Plastic resin (flammability to UL 94V-0)
Weight
166 g
Cooling Method
Free air convection
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
( 74.1 x 54.1 x 21.8 mm ) Tolerance 0.5 mm
-1-
VER : B_8
update : 2015.11.16
AC-DC Power Module
ANC50
SERIES
50 Watts
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
Safety
EMC
( Single Output )
Agency Approvals
ANC50-5S
CE, UL/cUL
EMI (Conducted & Radiated Emission)
EN 55022
EMS (Noise Immunity)
EN 55024
ANC50-12S
ANC50-15S
ESD
EN61000-4-2 air ± 8kV , Contact ± 4kV (A)
Radiated Immunity
EN61000-4-3 3V/m
(A)
Fast Transient
EN61000-4-4 ± 1kV
(A)
Surge
EN61000-4-5 ±2kV
(A)
Conducted Immunity
EN61000-4-6 3Vrms
PFMF
EN61000-4-8 1A/m (A)
Dips
EN61000-4-11 30% 500ms (A)
ANC50-24S
ANC50-48S
(A)
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
2. It's recommended to add Varistor 14S471K at L / N input side in parallel.
3. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw
MECHANICAL DIMENSION
BLOCK DIAGRAM
( Top View )
PIN#
Single
1
AC IN (N)
2
AC IN (L)
3
-DC OUT
4
+DC OUT
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319