ACDC 50150 Watts DLG Series xppower.com • AC Input LED Driver • Constant Voltage & Current Operation • High Power Factor • High Efficiency • Water Proof to IP67 • 90305 VAC Input Voltage Range • 3 Year Warranty Specification Input General • 90-305 VAC, see derating curve • 47-63 Hz • 50 W: 1.0 A at 115 VAC, 0.5 A at 230 VAC, 75 W: 1.2 A at 115 VAC, 0.6 A at 230 VAC, 100 W: 1.4 A at 115 VAC, 0.7 A at 230 VAC, 150 W: 2.0 A at 115 VAC, 1.0 A at 230 VAC Inrush Current • 65 A at 230 VAC, cold start +25 °C Power Factor • >0.94 at 230 VAC, full load Earth Leakage Current • DLG50/75: 500 µA max at 230 VAC DLG100/150: 750 µA max at 230 VAC No Load Input Power • 0.6 W max at 230 VAC Input Protection • DLG50/75 T2.5A/300V fuse fitted in line, DLG100 T3.15A/300V fuse fitted in line, DLG150 T4A/300V fuse fitted in line Input Voltage Input Frequency Input Current Output Output Voltage Minimum Load Start Up Delay Hold Up Time • • • • Line Regulation Load Regulation • • Turn On Overshoot Transient Response • • Ripple & Noise • Overvoltage Protection • Overtemperature Protection Overload Protection Short Circuit Protection Temperature Coefficient • See table No minimum load required 1.5 s max at 115 VAC DLG50/75: No hold up DLG100/150: 16 ms minimum ±0.5% ±1.0% in constant voltage mode, ±5.0% in constant current mode 5% max 5% maximum deviation, recovery to within 1% in 10 ms for a 50% load change DLG50/75(1) DLG100/150: 150 mV pk-pk up to 36 V output, 200 mV for 48 V output, 240 mV for ≥54 V output (see note 2) 110-142%, recycle mains to reset, only on DLG100 & DLG150 versions Unit shuts down, recycle mains to reset • 105% maximum, auto recovery • Trip and restart (hiccup mode) • 0.04%/°C Notes 1. DLG50/75 use a topology which results in increased levels of mains frequency related ripple. Contact technical sales for details. Efficiency Isolation Switching Frequency MTBF • See table • 3750 VAC Input to Output 1880 VAC Input to Ground 500 VAC Output to Ground • DLG50/75: 40-80 kHz DLG100/150: PWM 60-80 kHz, PFC 55-133 kHz • >200 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature • DLG50/75: -40 °C to +60 °C (see derating curve), DLG100/150: -30 °C to +70 °C (see derating curve) Operating Humidity • 5-100% RH, non-condensing Storage Temperature • -40 °C to +80 °C Operating Altitude • 3000 m Vibration • 10-500 Hz, 2 g, 10 mins/cycle, 6 cycles in each of 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals • EN55015, class B conducted and radiated • EN61000-3-2, class A EN61000-3-2, class C for loads >80% • EN61000-3-3 • EN61000-4-2, 8 kV air and 4 kV contact, Perf Criteria A • EN61000-4-3, level 2 Perf Criteria A • EN61000-4-4, level 2 Perf Criteria A • EN61000-4-5, installation class 3, Perf Criteria A • EN61000-4-6, level 2 Perf Criteria A • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B • EN61347, UL8750, CE Mark DLG100/150: IEC60950-1, EN60950-1, UL60950-1 Output Power Output Voltage 50 W 50 W 50 W 50 W 59 W 75 W 74 W 75 W 67 W 75 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 132 W 150 W 150 W 150 W 150 W 150 W 150 W 12.0 24.0 36.0 48.0 12.0 24.0 30.0 36.0 48.0 54.0 12.0 15.0 24.0 30.0 36.0 48.0 57.0 12.0 15.0 24.0 30.0 36.0 48.0 54.0 Output Voltage Range in Constant Current Mode 8.5-12.0 V 19.0-24.0 V 26.0-36.0 V 35.0-48.0 V 8.5-12.0 V 19.0-24.0 V 22.0-30.0 V 26.0-36.0 V 35.0-48.0 V 37.0-54.0 V 9.0-12.0 V 10.0-15.0 V 14.0-24.0 V 22.0-30.0 V 26.0-36.0 V 34.0-48.0 V 43.0-57.0 V 9.0-12.0 V 11.0-15.0 V 14.0-24.0 V 22.0-30.0 V 26.0-36.0 V 33.0-48.0 V 38.0-54.0 V Output Current V V V V V V V V V V V V V V V V V V V V V V V V 4.20 2.10 1.40 1.05 4.90 3.15 2.45 2.10 1.40 1.40 8.30 6.60 4.20 3.30 2.80 2.10 1.75 11.00 10.00 6.30 5.00 4.20 3.20 2.80 A A A A A A A A A A A A A A A A A A A A A A A A Efficiency(1) Model Number 84.0% 86.0% 88.0% 88.0% 84.0% 86.0% 87.0% 88.0% 88.0% 88.0% 88.0% 88.0% 90.0% 90.0% 90.0% 90.5% 90.5% 88.0% 88.0% 90.0% 90.0% 90.0% 90.0% 90.0% DLG50PS12 DLG50PS24 DLG50PS36 DLG50PS48 DLG75PS12 DLG75PS24 DLG75PS30 DLG75PS36 DLG75PS48 DLG75PS54 DLG100PS12 DLG100PS15(3) DLG100PS24 DLG100PS30 DLG100PS36 DLG100PS48 DLG100PS57(3) DLG150PS12 DLG150PS15(3) DLG150PS24 DLG150PS30 DLG150PS36 DLG150PS48 DLG150PS54(3) Notes 1. Typical efficiency at full load and 230 VAC input. 2. Measured using 12” twisted pair with 0.1 µF and 47 µF capacitors in parallel at 20 MHz bandwidth. 3. Not UL8750 approved. Mechanical Details A B 0.28 (7.0) 2.68 (68.0) C 0.35 (8.9) 4-R2.1 AC IN 1.35 (34.2) DC OUT A B C ACL V+ (RED) ACN V- (BLACK) 18 AWGx2C (DLG50/75) 14 AWGx2C (DLG100/150) 18AWGx3C DLG50/75 DLG100/150 6.93 (176.0) 6.38 (162.0) 6.03 (153.2) 8.74 (222.0) 8.19 (208.0) 7.83 (199.0) Notes 0.35 (8.9) 11.81±0.79 (300±20) 11.81±0.79 (300±20) 1. All dimensions shown in inches (mm). 2. Weight: DLG50/75: 1.98 lbs (900 g) DLG100/150 2.29 lbs (1040 g) 3. Tolerance: ±0.02 (0.5) 1.54 (39.0) Application Notes Constant Voltage / Constant Current Curve Output Voltage Vo max Vo min Trip & Restart Zone 0 10 20 30 40 Derating Curve 100 A 50 60 70 Output Current (%) 100 B 20 0 80 C A DLG150 at 115 VAC B DLG150 at 230 VAC & DLG100 C DLG50/75 0 -30 for DLG100/150 -40 for DLG50/75 Load (%) Load (%) 40 20 30 Ambient Temp (˚C) 40 50 55 60 70 100 C 60 40 20 10 90 A B 80 60 80 0 90 A DLG50/75 B DLG100 C DLG150 100 115 130 180 220 240 305 Input Voltage (VAC) 60Hz Ta= 25˚C 03-Sep-13 ACDC DLG50150 Models and Ratings