AIMTEC AM5T-2405SH40-FZ 5 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM5T-FZ
5 Watt | DC-DC Converter
FEATURES:








RoHS compliant
24 Pin DIP Package
High efficiency up to 85%
Wide 2:1 input range
Operating temperature -40oC to + 85oC
Input / Output isolation 4000 VACrms
Pin compatible with multiple manufacturers
OLP, OVP and SCP
Models
Single Output
Model
Input
Voltage (V)
Output
Voltage (V)
Output Current
max (mA)
AM5T-1205SH40-FZ
AM5T-1212SH40-FZ
AM5T-1215SH40-FZ
AM5T-2405SH40-FZ
AM5T-2412SH40-FZ
AM5T-2415SH40-FZ
AM5T-4805SH40-FZ
AM5T-4812SH40-FZ
AM5T-4815SH40-FZ
9 -18
9 -18
9 -18
18 - 36
18 - 36
18 - 36
36 - 75
36 - 75
36 - 75
5
12
15
5
12
15
5
12
15
1000
500
400
1000
500
400
1000
500
400
Model
Input
Voltage (V)
Output
Voltage (V)
Output Current
max (mA)
AM5T-1212DH40-FZ
AM5T-1215DH40-FZ
AM5T-2412DH40-FZ
AM5T-2415DH40-FZ
AM5T-4812DH40-FZ
AM5T-4815DH40-FZ
9 -18
9 -18
18 - 36
18 - 36
36 - 75
36 - 75
±250
±200
±250
±200
±250
±200
Capacitive load,
max (μF)
Efficiency
(%)
Isolation
(VAC)
81
83
83
82
85
84
81
83
82
4000
4000
4000
4000
4000
4000
4000
4000
4000
Capacitive load,
max (μF)
Efficiency
(%)
Isolation
(VAC)
±220
±220
±220
±220
±220
±220
83
83
84
85
83
83
4000
4000
4000
4000
4000
4000
2000
470
440
2000
470
440
2000
470
440
Models
Dual Output
±12
±15
±12
±15
±12
±15
Input Specifications
Parameters
Voltage range
Filter
Turn on Transient process time
(50% load step Change)
Transient response over shoot
Input reflected ripple current
Start up time
Absolute Maximum Rating
Nominal
Typical
12
24
48
9-18
18-36
36-75
Maximum
Units
VDC
Pi Type

di/dt=0.8A/µs
Vin nominal FL
<±5%
12 Vin
24 Vin
48 Vin
-0.7-25
-0.7-50
-0.7-100
100
Peak Input Voltage time
780
µs
76
510
% of Vo
mA p-p
ms
VDC
ms
Isolation Specifications
Parameters
Rated I/O voltage
Tested I/O voltage
Resistance
Capacitance
www.aimtec.com
F 051e R11.C
Conditions
Typical
60 sec
1sec flash test
500VDC
> 1000
12
Tel: +1 514 620 2722
1 of 3
Rated
Units
4000
6000
VACrms
Vpk
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM5T-FZ
5 Watt | DC-DC Converter
Output Specifications
Parameters
Conditions
Typical
Over load protection
Over voltage protection
Zener Diode Clamp
Voltage accuracy
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
25% load to full load
Load voltage regulation (Dual)
LL to LH at Full Load
25% load to full load
Balanced
Unbalanced load 25% to
100% full load
Temperature coefficient
Ripple & Noise
(At 20MHz Bandwidth)
Maximum
120%
5V model = 6.2V
12V model = 15V
15V model = 18V
±1
Continuous
Autorecovery
±0.5
±0.5
±0.5
±3.0
Units
of full load
Vdc
%
%
%
%
%
%/oC
±0.02
150
70
200
5V output
12V output
15V output
mV p-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions(L x W x H)
MTBF
Conditions
Typical
100% load
Full Load (with derating see chart)
Maximum
Units
+95
KHz
oC
oC
oC
150
-40 to +85
-50 to +125
Free air convection
95
%
Non-Conductive Plastic
16
g
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.80 x 0.5 inches
31.7x 20.3 x 12.65 mm
>700 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Dimensions
Pin
1
2
10
11
12
13
15
23
24
Single
+V Input
+V Input
N. C.
N.C.
-V output
+Voutput
N. C.
-V Input
-V Input
31.70
(1.25)
12.65
(0.5)
Dual
+V Input
+V Input
Common
Common
N. C.
-V output
+V output
-V Input
-V Input
1.88
(0.07)
SIDE
0.5
(0.02)
31.70
(1.25)
20.3
(0.8)
2.55
(0.1)
1 2
10 11 12
15.20
(0.6)
15
24 23
2.54
(0.1)
20.32
(1.25)
13
5.08
(0.2)
BOTTOM
www.aimtec.com
F 051e R11.C
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM5T-FZ
5 Watt | DC-DC Converter
Derating
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R11.C
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages