ETC A41-130-20 International standards at lower cost and better performance Datasheet

All-4-One™ International Transformers
Chassis Mount
International Standards at Lower Cost and Better Performance
SM
Designed to provide the high isolation, creepage and clearance necessary
to comply with international safety standards.
General Specifications
• Power - 25 VA to 175 VA
• Dielectric Strength - 4000 VRMS Hipot
• Primaries - Dual primaries (115/230 V - 50/60 Hz)
• Dual Secondaries - Series or parallel
• Terminals - Solder lug / quick connect type terminals
• Leakage - Current meets UL 60601-1, IEC/EN 60601-1
• Insulation - Class F (155º C)
• Flammability Rating - Bobbin and shroud material meet UL 94-V0
Agency Certifications
• UL 1446 E66312
• UL recognized to UL 506, File # E63829
• CSA certified to C22.2 #66, File # 221070
• VDE certified to VDE 0805 / EN 60950, File # 1448
• Agency certified versions available with lead wires
Part Number
VA
Secondary RMS Rating
Size
Series
Parallel
A41-25-10
25
10VCT @ 2.5A
5V @ 5.0A
A41-43-10
43
10VCT @ 4.3A
5V @ 8.6A
A41-80-10
80
10VCT @ 8.0A
5V @ 16.0A
A41-130-10
130
10VCT @ 13.0A
5V @ 26.0A
A41-175-10
175
10VCT @ 17.5A
5V @ 35.0A
A41-25-12
25
12.6VCT @ 2.0A
6.3V @ 4.0A
A41-43-12
43
12.6VCT @ 3.4A
6.3V @ 6.8A
A41-80-12
80
12.6VCT @ 6.3A
6.3V @ 12.6A
A41-130-12
130
12.6VCT @ 10.3A
6.3V @ 20.6A
A41-175-12
175
12.6VCT @ 14.0A
6.3V @ 28.0A
A41-25-16
25
16VCT @ 1.6A
8V @ 3.2A
A41-43-16
43
16VCT @ 2.7A
8V @ 5.4A
A41-80-16
80
16VCT @ 5.0A
8V @ 10.0A
A41-130-16
130
16VCT @ 8.1A
8V @ 16.2A
A41-175-16
175
16VCT @ 11.0A
8V @ 22.0A
A41-25-20
25
20VCT @ 1.25A
10V @ 2.5A
A41-43-20
43
20VCT @ 2.2A
10V @ 4.4A
A41-80-20
80
20VCT @ 4.0A
10V @ 8.0A
A41-130-20
130
20VCT @ 6.5A
10V @ 13.0A
A41-175-20
175
20VCT @ 8.8A
10V @ 17.6A
A41-25-24
25
24VCT @ 1.0A
12V @ 2.0A
A41-43-24
43
24VCT @ 1.8A
12V @ 3.6A
A41-80-24
80
24VCT @ 3.3A
12V @ 6.6A
A41-130-24
130
24VCT @ 5.4A
12V @ 10.8A
A41-175-24
175
24VCT @ 7.3A
12V @ 14.6A
A41-25-28
25
28VCT @ 0.9A
14V @ 1.86A
A41-43-28
43
28VCT @ 1.5A
14V @ 3.0A
A41-80-28
80
28VCT @ 2.8A
14V @ 5.6A
A41-130-28
130
28VCT @ 4.6A
14V @ 9.2A
A41-175-28
175
28VCT @ 6.25A
14V @ 12.5A
A41-25-36
25
36VCT @ 0.7A
18V @ 1.4A
A41-43-36
43
36VCT @ 1.2A
18V @ 2.4A
A41-80-36
80
36VCT @ 2.2A
18V @ 4.4A
A41-130-36
130
36VCT @ 3.6A
18V @ 7.2A
A41-175-36
175
36VCT @ 4.8A
18V @ 9.6A
A41-25-230
25
230VCT @ 0.11A
115V @ 0.22A
A41-43-230
43
230VCT @ 0.19A
115V @ 0.38A
A41-80-230
80
230VCT @ 0.35A
115V @ 0.7A
A41-130-230
130
230VCT @ 0.57A
115V @ 1.14A
A41-175-230
175
230VCT @ 0.76A
115V @ 1.52A
�
�
����
��������
�
�
�
��
����
��������
��
�
��
�����������������������
Note: VDE certified lead wire versions available.
©2006 Signal Transformer Inc. Specifications subject to change without notice. 07.06
500 Bayview Avenue, Inwood, NY 11096
Toll Free 866-239-5777 • Tel 516-239-5777 • Fax 516-239-7208
[email protected][email protected]
www.signaltransformer.com
1
All-4-One™ International Transformers
Chassis Mount
International Standards at Lower Cost and Better Performance
Dimensions
Mounting
DImenstions
Terminals
VA
L
W
H
A
B
C
Inches
(mm)
Size
Inches
(mm)
SM
Weight
Mounting Style
ML
MW
Mounting Screw
lbs
(kg)
25
2.81
(71.4)
2.14
(54.4)
2.31
(58.7)
2.00
(50.8)
1.12
(28.6)
.31
(7.9)
.187
(4.75)
C
2.37
(60.3)
–
#6
1.25 lbs
(0.57)
43
3.12
(79.4)
2.14
(54.4)
2.68
(68.2)
2.25
(57.2)
1.12
(28.6)
.31
7.9)
.187
(4.75)
C
2.81
(71.4)
–
#6
1.6 lbs
(0.73)
80
2.50
(63.5)
2.52
(64.3)
3.00
(76.2)
–
1.37
(35.0)
.31
(7.9)
.187
(4.75)
B
2.00
(50.8)
2.18
(55.5)
#6
2.8 lbs
(1.27)
130
2.81
(71.4)
3.00
(76.2)
3.37
(85.7)
–
1.62
(41.3)
.37
(9.5)
0.25
(6.35)
B
2.25
(57.2)
2.50
(63.5)
#8
4.1 lbs
(1.86)
175
3.12
(79.4)
3.14
(79.7)
3.75
(95.3)
–
1.62
(41.3)
.37
(9.5)
0.25
(6.35)
B
2.50
(63.5)
2.50
(63.5)
#8
5.5 lbs
(2.49)
©2006 Signal Transformer Inc. Specifications subject to change without notice. 07.06
500 Bayview Avenue, Inwood, NY 11096
Toll Free 866-239-5777 • Tel 516-239-5777 • Fax 516-239-7208
[email protected][email protected]
www.signaltransformer.com
2