Click on Series name for product info on aimtec.com Series AM2LV-NZ 2 Watt | DC-DC Converter FEATURES: SMD Package Wide (2:1) Input Range 1500 VDC Isolation Continuous Short Circuit Protection Operating Temperature: -40°C To +85°C Regulated Single / Dual Output MTBF >1,000,000 Hours RoHS Compliant Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) 9-18 9-18 9-18 18-36 18-36 18-36 3.3 5 12 3.3 5 12 500 400 167 500 400 167 1500 1500 1500 1500 1500 1500 70 74 78 72 76 80 Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) AM2LV-1203S-NZ AM2LV-1205S-NZ AM2LV-1212S-NZ AM2LV-2403S-NZ AM2LV-2405S-NZ AM2LV-2412S-NZ Models Dual output Model AM2LV-1209D-NZ 9-18 ±9 ±111 1500 76 AM2LV-1212D-NZ 9-18 ±12 ±83 1500 78 AM2LV-1215D-NZ 9-18 ±15 ±67 1500 80 AM2LV-2405D-NZ 18-36 ±5 ±200 1500 74 AM2LV-2409D-NZ 18-36 ±9 ±111 1500 76 AM2LV-2412D-NZ 18-36 ±12 ±83 1500 78 AM2LV-2415D-NZ 18-36 ±15 ±67 1500 80 NOTE: Unless otherwise specified, all specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load. Input Specifications Parameters Voltage range Absolute Maximum Rating Nominal Typical 12 24 12 24 9-18 18-36 Maximum Units VDC 22 40 100 Peak Input Voltage time VDC ms Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions Typical 60 sec At 500 VDC Input to Output Rated Units 1500 VDC MOhm pF 1000 85 Output Specifications Parameters Voltage accuracy Short Circuit protection Short circuit restart Line voltage regulation (Single) Load voltage regulation (Single) Load voltage regulation (Dual) Conditions Typical ±5 Continuous Auto-Recovery ±0.5 ±1 From Low in to High In From 10% to 100% load From 10% to 100% load Each output loaded within 5% of each other Temperature coefficient www.aimtec.com F 051e R8.G Tel: +1 514 620 2722 1 of 4 Maximum Units % % % ±5 % ±0.03 %/oC Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2LV-NZ 2 Watt | DC-DC Converter Output Specifications (continued) Parameters Ripple & Noise * Minimum Load Current** Conditions Typical 20MHz Bandwidth with 10% load 75 10 Maximum Units mV p-p % of Max * Test Ripple & Noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick & POL DC-DC Converters” available on Aimtec’s website www.aimtec.com. Converters are designed to operate with a minimum load of 10%. If converter is operated with a load less than 10% the ripple will increase. ** Operation under 10% load will not damage the converter; However, not all specifications will be met. General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum Soldering Temperature Conditions Typical 100% load 300 Maximum KHz oC oC oC %/ oC -40 to +85 -55 to +125 Above 71º Units 2.9 Free Air Convection 95 Plastic (UL94-V0) 5.2 0.94 x 0.54 x 0.32 inches 23.86 x 13.70 x 8.20 mm >1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25ºC) 1.5mm from case for 10 seconds 260 % RH g oC Pin Out Specifications Pin Single Dual 1 7 8 9 10 16 - Vin NC NC +Vout - Vout + Vin - Vin NC Common +Vout -Vout + Vin NC – not connected Dimensions www.aimtec.com F 051e R8.G Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2LV-NZ 2 Watt | DC-DC Converter Recommended Filter Circuit Single Output Dual Output + Vin Cout + Cin + DC DC Cin + Common Cout +Vout + Vin +Vout DC DC Cout + + - Vout -Vout - Vin - Vin All the AM2LV-Z Series have been tested with the above recommended test circuit. This series should be tested under load. If it is necessary to further decrease the input/output ripple, the value of the filter capacitor can be increased; a capacitor with a low ESR should be used. Excessive filter capacitance can cause start up problems with the converter. In general, the recommended capacitance values are: Cin: 12V input 100μF, 24V input 10μF~47μF Cout: 10μF/100mA Refer to table below for maximum capacitor values: External Capacitor Value Single Output Vout (VDC) Cout (µF) 3.3 5 9 12 15 2200 1000 680 470 330 Dual Output Vout (VDC) Cout (µF) ±5 ±9 ±12 ±15 ±680 ±470 ±330 ±220 Output Power (%) Derating www.aimtec.com F 051e R8.G Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2LV-NZ 2 Watt | DC-DC Converter Typical Efficiency Chart Examples NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R8.G Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only