EPCOS B44066T0010E402 Thyristor module tsm-lc10 Datasheet

Thyristor module TSM-LC10
Series/Type:
TSM
Ordering code: B44066T0010E402
Date:
Version:
November 2006
1
Content of inside pages of data sheet. Data will be automatically entered into frontpage
headlines, headers and footers. Please fill in the table and then change the colour to “White”.
This ensures that the table disappears for the customer pdf.
Identification/Classification 1:
(header 1)
Thyristor module for dynamic PFC
Identification/Classification 2:
(header 2)
Accessories for power factor correction
Ordering code:
B44066T0010E402
Series/Type:
Thyristor module TSM-LC10
Preliminary data (optional):
(if necessary)
Preliminary data
Department:
FK PC PM PFC
Date:
November 2006
© EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Thyristor module for dynamic PFC
Accessories for power factor correction
B44066T0010E402
Thyristor module TSM-LC10
Preliminary data
Characteristics
„ Fast electronically controlled self observing thyristor switch
„ For capacitive loads up to 12.5 kvar
„ Suitable for designing dynamic PFC-systems in 380 and
400 V grids
„ Micro-processor controlled alignment to tuned or
detuned capacitor branches (up to 14 %) for optimized
switching behaviour
„ No system perturbation due to switching operations
(transients)
„ Switching without delay
„ Maintenance-free
„ Long useful service life
„ No noise emission during switching operation
„ Compact module ready for connection
„ No auxiliary voltage required
Features
•
Easy installation
-
Mechanical assembly directly on a mounting plate
-
Self check after turn-on of main voltage
-
Optimized switching behaviour to the connected load
(tuned/detuned) via the internal processor
-
Storage of optimized parameters for optimum switching
behaviour
•
Mounting position
-
Upright; minimum 100 mm space on top and below
•
Display and control via LED display
-
Operation
-
Faults
-
Activation
-
Voltage
-
Operating state
•
Permanent self-monitoring
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
November 2006
Page 2 of 6
Thyristor module for dynamic PFC
Accessories for power factor correction
B44066T0010E402
Thyristor module TSM-LC10
Preliminary data
Technical data
Dimensions
162 × 150 × 75 mm (w × h × d)
Weight
Approx. 1.75 kg
Rated voltage
380 … 400 V
Maximum voltage
- in conventional PFC-systems (without reactors)
440 V
- in detuned PFC-systems (7 % detuning)
440 V (no upwards tolerance permitted)
- in detuned PFC-systems (14 % detuning)
400 V
Frequency
50/60 Hz
Switching capability
Nominal output 10 kvar at 400 V
Max. 12.5 kvar at 400 V with ambient temperature
<40 °C
Activation
10 … 24 V DC (approx. 20 mA) via terminal clamp,
internally electrically isolated
Switching time
Approx. 5 ms
Reset time
Depending on degree of detuning and dimension of
discharge resistor
Display
2 status LEDs per phase: operation/fault and triggering
signal
Power circuit
Direct connection 4 pole via terminal clamps
(D = 6 mm2 resp. 4 mm2), connection from the bottom
Power dissipation
Fuses (mandatory for protection of components)
Ambient operating temperature at nominal load
PD (in W) = 2.0 × I (in A);
at 400 V/12.5 kvar approx. 35 W
3 × electronic fuse „superfast“
NH00 AC 690 V, characteristic gRL
12.5 kvar: 35 A (e.g. SIBA Art.No. 20.477.20-35)
-10 °C … +55 °C
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
November 2006
Page 3 of 6
Thyristor module for dynamic PFC
Accessories for power factor correction
B44066T0010E402
Thyristor module TSM-LC10
Preliminary data
Connection diagram: three-phase load (standard)
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
November 2006
Page 4 of 6
Thyristor module for dynamic PFC
Accessories for power factor correction
B44066T0010E402
Thyristor module TSM-LC10
Preliminary data
Cautions and Warnings
General
• Thyristor modules TSM series may only be used for the purpose they have been designed for.
• Thyristor modules TSM series may only be used in combination with appropriate pre-switched grid
separator device.
• Thyristor modules have to be projected in such a way that in case of any failure no uncontrolled
high current and voltages may occur.
• The devices in operation have to be protected against moisture and dust, sufficient cooling has to
be assured.
Attention
Due to the switching principle of the thyristor module the power capacitors are permanently loaded to
the peak value of the grid voltage (DC voltage) even when switched off. Therefore following rules
have to be obeyed in any case:
• For standard PFC-systems (without reactors) power capacitors of 440 V nominal voltage have to
be used; for detuned systems PFC capacitors of 525 V nominal voltage have to be used.
• Due to the high voltage (2 x peak value of nominal voltage) that occurs, the discharge resistors of
the power capacitors have to be replaced by special types (accessory EW22).
• In dynamic systems with TSM modules no fast discharge reactors may be used (reactor = DCwise short circuit).
• For standard PFC-systems 2 current limiting reactors are mandatory per thyristor module
(accessory BD100).
• Thyristor modules in general have to be protected by superfast electronic fuses. Principles for
dimensioning have to be considered. Fuses in the system have to be marked.
• Due to the special switching, the PFC capacitors are fully loaded even when the particular step
has been switched off. Protection against contact has to be guaranteed. Warning signals in the
systems are required.
• Even in switched off state no electrical isolation is achieved for electronic switches. Therefore
parts of the systems may not be touched after switching off the complete system before the
capacitors have been completely discharged.
FAILURE TO FOLLOW CAUTIONS MAY RESULT, WORST CASE, IN PREMATURE FAILURES OR
PHYSICAL INJURY.
U Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual
version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case,
bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications.
Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to
approve our product specifications or request our approval for your specification before ordering.
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
November 2006
Page 5 of 6
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of
suitable design of the customer application or other action taken by the customer (e.g. installation
of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the
event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently,
we cannot guarantee that all products named in this publication will always be available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, EPCOS-JONES, Alu-X, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,
PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap,
WindCap are trademarks registered or pending in Europe and in other countries. Further
information will be found on the Internet at www.epcos.com/trademarks.
FK PC PM PFC
November 2006
Page 6 of 6
Similar pages