Online data sheet FFUS10-1N1IO FFU FLOW SENSORS FFUS10-1N1IO | FFU FLOW SENSORS A B C D E F H I J K L M N O P Q R S T Ordering information Type Part no. FFUS10-1N1IO 6047868 Other models and accessories www.sick.com/FFU Illustration may differ Features Medium Fluids Nominal width measuring tube DN 10 Process temperature 0 °C ... +80 °C Process pressure Max. 16 bar Performance Minimim flow ≤ 0.3 l/min Maximum flow ≤ 21 l/min Inlet zone 10 cm Output zone 0 cm Conductivity No limitation Accuracy of sensor element 2 % (of final value) 1) Reproducibility ≤ 0.5 % Resolution 0.003 l/min 1) Reference condition: Water, zero gas, measuring tube completely full, no cavitation, temperature of medium 20 °C, ambient temperature 20 °C ... 25 °C, compliance with inlet and outlet zones, warm-up time for electronics: 30 min. Electronics Supply voltage 18 V DC ... 30 V DC 1) Residual ripple ≤ 5 Vpp 2) Power consumption ≤ 180 mA 3) Initialization time ≤5s Protection class III Electrical connection Round connector M12 x 1, 5-pin 1) 2) 3) 4) 5) 2 All connections are polarity protected. All outputs are overload and short-circuit protected. May not exceed or fall below Uv tolerances. Without load. There are 100 mA for each output pnp and npn available. Analog output and display. FLUID SENSORS | SICK Online data sheet | 2017-02-08 13:58:08 Subject to change without notice FFUS10-1N1IO | FFU FLOW SENSORS Output signal Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type) 1) Output current < 100 mA 4) Output load < 500 Ohm Lower signal level 3.8 mA ... 4 mA Upper signal level 20 mA ... 20.5 mA Impuls/frequency output 0 kHz ... 10 kHz Puls width ≤1s Signal voltage HIGH Vs - 2 V Signal voltage LOW ≤2V Inductive load 1H Capacitive load 100 nF Response time Filter off 100 ms, filter low 300 ms, filter medium 1 s, filter strong 4.2 s 5) 1) 2) 3) 4) 5) All connections are polarity protected. All outputs are overload and short-circuit protected. May not exceed or fall below Uv tolerances. Without load. There are 100 mA for each output pnp and npn available. Analog output and display. Mechanics Process connection ½" NPT Wetted parts PPSU Housing material PPSU Enclosure rating IP 67 Weight 340 g Ambient data Ambient operating temperature 0 °C ... +60 °C Ambient storage temperature –20 °C ... +70 °C Classifications ECl@ss 5.0 27371815 ECl@ss 5.1.4 27371815 ECl@ss 6.0 27371815 ECl@ss 6.2 27371815 ECl@ss 7.0 27371815 ECl@ss 8.0 27371815 ECl@ss 8.1 27371815 ECl@ss 9.0 27371815 ETIM 5.0 EC002580 ETIM 6.0 EC002580 2017-02-08 13:58:08 | Online data sheet Subject to change without notice FLUID SENSORS | SICK 3 FFUS10-1N1IO | FFU FLOW SENSORS 41112501 Dimensional drawing (Dimensions in mm (inch)) DN 10, ½" NPT 14.7 (0.58) 5 (0.20) M12x1 1/2" NPT 83.1 (3.27) 84 (3.31) 147 (5.79) 12 (0.47) H I J K L M N O P Q R S T UNSPSC 16.0901 1/2" NPT A B C D E F Connection type 1 2 5 4 3 ① ② ③ ④ ⑤ 4 L+: Supply voltage Q1: Digital output PNP/NPN M: Ground C: Communication QA: Analog current output FLUID SENSORS | SICK Online data sheet | 2017-02-08 13:58:08 Subject to change without notice Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” Worldwide presence: Contacts and other locations – www.sick.com SICK AG | Waldkirch | Germany | www.sick.com