PAIRUI BAH48-33V40 Dc-dc converter Datasheet

DC-DC Converter
Bricks, Open/Enclosed
BAH SERIES, 1/2 BRICK, UP TO 300W
FEATURES:
5 years warranty
1500Vdc isolation voltage
Output current up to 60A
Efficiency up to 93%
Operating temperature range -40°C to +85°C
Under voltage, over current, short circuit,
over voltage protection
Remote on/off
Adjustable output voltage
Output voltage
(Vdc)
Output current
(A)
Efficiency
Typ.
BAH48-25V30
2.5
30.0
88%
BAH48-25V40
BAH48-25V50
2.5
40.0
90%
2.5
50.0
89%
BAH48-25V60
2.5
60.0
87%
BAH48-33V15
3.3
15.0
91%
BAH48-33V25
3.3
25.0
92%
BAH48-33V30
3.3
30.0
93%
3.3
40.0
89%
BAH48-33V50
3.3
50.0
89%
BAH48-33V60
3.3
60.0
89%
BAH48-50V15
5.0
15.0
94%
BAH48-50V20
5.0
20.0
92%
BAH48-50V30
5.0
30.0
93%
BAH48-50V40
5.0
40.0
92%
BAH48-120V25
12.0
25.0
93%
Model
BAH48-33V40
Input voltage
(Vdc)
48(36~72)
Notes:
1. Other input and output models may available on request;
2. You may request for the models with heatsink, plus “R” in the suffix, e.g. BAH48-25V30R.
ELECTRICAL
Input voltage range
48Vdc
36-72Vdc
OFF: High level or left close
Negative logic
ON: Low level or grounded
Remote control
ON: High level or left open
Positive logic
Output power
www.pairuigroup.com
OFF: Low level or grounded
Input voltage range
Page:
50-300W
1/4
Date: 01/23/2014
DC-DC Converter
Bricks, Open/Enclosed
BAH SERIES, 1/2 BRICK, UP TO 300W
ELECTRICAL
Output voltage
Single output
Output voltage accuracy
Input voltage range
Output voltage adjustable
Positive
Line regulation
Full load
±0.2%
Load regulation
10%-100% full load
±0.5%
Dynamic response
(transient/recovery time)
2.5/3.3/5/12Vdc
±1%
-20% - +10%
25%-50%-75% load capability
Ripple and noise
Parallel test, 20MHz wide range
Operating frequency
Typical value
Isolation voltage
∆Vo/∆t: ±4.0%/500μs
180mVp-p max.
250KHz typ.
Input to output
1500Vdc
Input to case
1050Vdc
Output to case
500Vdc
Isolation resistance
---
10MΩ
Safety
---
Temperature coefficient
---
Operating temperature range
Auxiliary heat sink
Storage temperature range
---
Over temperature protection
Typical
Under voltage protection
---
Yes
Over current protection
---
Yes
Short circuit protection
---
Yes
Over voltage protection
---
Yes
Relative humidity
---
95% max.
Packing
---
Hole package
MTBF
Bellcore TR-332, 25°C
IEC-60950-1, UL-60950-1
EN-60950-1, GB4943
300ppm
-40°C to +85°C
-40°C to +125°C
110°C typ.
2x106Hrs
Notes: Unless otherwise specified, all the parameters of the test conditions are as follows: ambient temperature
25 , the nominal input voltage, pure resistive nominal load.
℃
www.pairuigroup.com
Page:
2/4
Date: 01/23/2014
DC-DC Converter
Bricks, Open/Enclosed
BAH SERIES, 1/2 BRICK, UP TO 300W
MECHANICAL
WITHOUT HEATSINK
WITH HEATSINK
PCB LAYOUT
CONNECTION
PIN #
SINGLE
1
-Vin
2
FG
3
REM
4
+Vin
5
GND
6
-S
7
TRIM
8
+S
9
+Vo
Note:
* Unit is mm(inch).
DERATING CURVE
www.pairuigroup.com
EFFICIENCY CURVE
Page:
3/4
Date: 01/23/2014
DC-DC Converter
Bricks, Open/Enclosed
BAH SERIES, 1/2 BRICK, UP TO 300W
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
NOTES
1. TVS&FUSE be helpful with over voltage protection and inrush limiting. Recommended FUSE better be 1.5~2times of
the rated current .
2. The input filter capacitor C6 could select the aluminum electrolytic capacitors or tantalum capacitors, and the
withstand voltage should be greater than the highest input voltage. Recommended capacitor should be between
22μF~100μF.
3. C1,C2 for the input filter capacitor,0.1~1μF high-frequency ceramics capacitor or chip capacitor are recommended.
The withstand voltage of output filter C5, C7 should be greater than the highest output voltage. Recommended
capacitor of C7 better within 100μF and C5 connected with the chip to reduce the input voltage peak, recommended
0.1~1μF high-frequency ceramics capacitor or chip capacitor.
www.pairuigroup.com
Page:
4/4
Date: 01/23/2014