TESTING HIGHLY SENSITIVE 1500 V FCC SURGE WITHSTANDING MINIATURE RELAY FEATURES 9.9 .390 35.24 1.387 9.8 .386 9.9 .390 20 .787 DS4E 15 .590 DS-RELAYS 9.8 .386 9.9 .390 9.8 .386 DS2E DS1E mm inch • High sensitivity: 200 mW pick-up power 100 mW pick-up power types available • Latching types available • High switching capacity: 60 W, 125 V A • High breakdown voltage: 1,500 V FCC surge between open contacts 1,000 V AC between open contacts • DIP-1C type can be used with 14 pin IC socket 2C type can be used with 16 pin IC socket, 4C type can be used with 2 sets of 14 pin IC sockets • Gold-cap silver palladium types available for 2 Form C type • Bifurcated contacts are standard SPECIFICATIONS Characteristics (at 20°C 68°F) Contact Arrangement 1 Form C, 2 Form C, 4 Form C Initial contact resistance, max. 50 mΩ (By voltage drop 6 V DC 1 A) Contact material Gold-clad sliver Max. switching power 60 W, 125 VA Max. switching voltage 220 V DC, 250 V AC Rating (resistive) Max. switching current 2 A DC, AC Max. carrying current 3 A DC, AC Mechanical 108 Expected (at 600 cpm) (1 Form C 2 coil latching type: 107) life (min. operations) Electrical 5×105 2 A 30 VDC resistive * Gold capped silver-palladium contact also available for 2 Form C 107 operations at 0.1 A 50 V DC resistive Coil (polarized) (at 20°C 68°F) Single side stable Minimum operating power Approx. 200 mW Nominal operating power Approx. 400 mW M 1 coil Minimum set and reset power Approx. 90 mW type latching Nominal set and reset power Approx. 180 mW Minimum set and reset power Approx. 180 mW 2 coil latching Nominal set and reset power Approx. 360 mW Approx. 100 mW (128 mW)* Single Minimum operating power side Nominal operating power Approx. 200 mW stable S 1 coil Minimum set and reset power type latching Nominal set and reset power Minimum set and reset power 2 coil latching Nominal set and reset power Approx. 45 mW (58 mW)* Approx. 90 mW Approx. 90 mW (115 mW)* Approx. 180 mW * For 1 Form C high sensitive types. Initial insuration resistance*1 Type of relay Initial Between open contacts breakdown volt- Between contacts sets age*2 Between contacts and coil FCC surge voltage between contacts and coil Operate time*3 (at nominal voltage) Release time (without diode)*3 (at nominal voltage) Set time*3 (at nominal voltage) Reset time*3 (at nominal voltage) Temperature rise (at nominal voltage, Contact current: 2A) Shock resistance Approx. 3 ms Approx. 2 ms Approx. 3 ms Approx. 3 ms Max. 65°C Ambient temp. Humidity 5 to 85% R.H. 1 Form C 2 Form C 4 Form C Approx. 3.2g .11oz Approx. 4g .14oz Approx. 7g .25oz Functional*6 Vibration resistance Destructive Unit weight 1,500 V (Expect DS1-S type) 1C, 2C:Min. 490 m/s2 {50 G} 4C:Min. 294 m/s2 {30 G} Min. 980 m/s2 {100 G} 10 to 55 Hz at double amplitude of 3.3 mm 10 to 55 Hz at double amplitude of 5 mm –40°C to +70°C –40°F to +158°F Functional*4 Destructive*5 Conditions for operation, transport and storage*7 (Not freezing and condensing at low temperature) 20 cpm at rated load 50 cps at low level load Min. 100 MΩ (at 500 V DC) (DS1-S type) (Other types) 500 Vrms 1,000 Vrms — 1,000 Vrms 1,000 Vrms 1,500 Vrms Remarks FCC (Federal Communication Commission) requests following standard as Breakdown Voltage specification. 1500V 750V 10 µs 160 µs 186 Max. operating speed * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10 mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms; detection time: 10µs *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10µs *7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61) DS TYPICAL APPLICATIONS • Telecommunication equipment • Office equipment • Computer peripherals • Security equipment • Measuring instrumentation ORDERING INFORMATION Ex DS Contact arrangement 1: 1 Form C 2: 2 Form C 4: 4 Form C 2 Classification of type E: Amber sealed type E M L2 Sensitivity M: 400 mW nominal operating power S: 200 mW nominal operating power DC 48 V Operating function Nil: Single side stable L: 1 coil latching L2: 2 coil latching R * Coil voltage DC 1.5, 3, 5, 6, 9, 12, 24, 48 V *Reverse polarity types available (add suffix-R). Standard packing: Carton: 50 pcs.; Case: 500 pcs. TYPES Single side stable Nominal Voltage, V DC 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 M (400 mW) type S (200 mW) type 1 Form C DS1E-M-DC1.5V DS1E-M-DC3V DS1E-M-DC5V DS1E-M-DC6V DS1E-M-DC9V DS1E-M-DC12V DS1E-M-DC24V DS1E-M-DC48V DS1E-S-DC1.5V DS1E-S-DC3V DS1E-S-DC5V DS1E-S-DC6V DS1E-S-DC9V DS1E-S-DC12V DS1E-S-DC24V DS1E-S-DC48V Part No. 2 Form C DS2E-M-DC1.5V DS2E-M-DC3V DS2E-M-DC5V DS2E-M-DC6V DS2E-M-DC9V DS2E-M-DC12V DS2E-M-DC24V DS2E-M-DC48V DS2E-S-DC1.5V DS2E-S-DC3V DS2E-S-DC5V DS2E-S-DC6V DS2E-S-DC9V DS2E-S-DC12V DS2E-S-DC24V DS2E-S-DC48V 4 Form C DS4E-M-DC1.5V DS4E-M-DC3V DS4E-M-DC5V DS4E-M-DC6V DS4E-M-DC9V DS4E-M-DC12V DS4E-M-DC24V DS4E-M-DC48V DS4E-S-DC1.5V DS4E-S-DC3V DS4E-S-DC5V DS4E-S-DC6V DS4E-S-DC9V DS4E-S-DC12V DS4E-S-DC24V DS4E-S-DC48V 1 Form C DS1E-ML-DC1.5V DS1E-ML-DC3V DS1E-ML-DC5V DS1E-ML-DC6V DS1E-ML-DC9V DS1E-ML-DC12V DS1E-ML-DC24V DS1E-ML-DC48V DS1E-SL-DC1.5V DS1E-SL-DC3V DS1E-SL-DC5V DS1E-SL-DC6V DS1E-SL-DC9V DS1E-SL-DC12V DS1E-SL-DC24V DS1E-SL-DC48V Part No. 2 Form C DS2E-ML-DC1.5V DS2E-ML-DC3V DS2E-ML-DC5V DS2E-ML-DC6V DS2E-ML-DC9V DS2E-ML-DC12V DS2E-ML-DC24V DS2E-ML-DC48V DS2E-SL-DC1.5V DS2E-SL-DC3V DS2E-SL-DC5V DS2E-SL-DC6V DS2E-SL-DC9V DS2E-SL-DC12V DS2E-SL-DC24V DS2E-SL-DC48V 4 Form C DS4E-ML-DC1.5V DS4E-ML-DC3V DS4E-ML-DC5V DS4E-ML-DC6V DS4E-ML-DC9V DS4E-ML-DC12V DS4E-ML-DC24V DS4E-ML-DC48V DS4E-SL-DC1.5V DS4E-SL-DC3V DS4E-SL-DC5V DS4E-SL-DC6V DS4E-SL-DC9V DS4E-SL-DC12V DS4E-SL-DC24V DS4E-SL-DC48V 1 Form C DS1E-ML2-DC1.5V DS1E-ML2-DC3V DS1E-ML2-DC5V DS1E-ML2-DC6V DS1E-ML2-DC9V DS1E-ML2-DC12V DS1E-ML2-DC24V DS1E-ML2-DC48V DS1E-SL2-DC1.5V DS1E-SL2-DC3V DS1E-SL2-DC5V DS1E-SL2-DC6V DS1E-SL2-DC9V DS1E-SL2-DC12V DS1E-SL2-DC24V DS1E-SL2-DC48V Part No. 2 Form C DS2E-ML2-DC1.5V DS2E-ML2-DC3V DS2E-ML2-DC5V DS2E-ML2-DC6V DS2E-ML2-DC9V DS2E-ML2-DC12V DS2E-ML2-DC24V DS2E-ML2-DC48V DS2E-SL2-DC1.5V DS2E-SL2-DC3V DS2E-SL2-DC5V DS2E-SL2-DC6V DS2E-SL2-DC9V DS2E-SL2-DC12V DS2E-SL2-DC24V DS2E-SL2-DC48V 4 Form C DS4E-ML2-DC1.5V DS4E-ML2-DC3V DS4E-ML2-DC5V DS4E-ML2-DC6V DS4E-ML2-DC9V DS4E-ML2-DC12V DS4E-ML2-DC24V DS4E-ML2-DC48V DS4E-SL2-DC1.5V DS4E-SL2-DC3V DS4E-SL2-DC5V DS4E-SL2-DC6V DS4E-SL2-DC9V DS4E-SL2-DC12V DS4E-SL2-DC24V DS4E-SL2-DC48V 1 coil latching Nominal Voltage, V DC 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 M (180 mW) type S (90 mW) type 2 coil latching Nominal Voltage, V DC M (360 mW) type S (180 mW) type 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 Notes: 1. Reverse polarity types available (add suffix-R). 2. Standard packing: carton: 50 pcs.; case: 500 pcs. 187 DS COIL DATA (at 20°C 68°F) Single side stable Nominal voltage, V DC M type S type 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 Pick-up voltage, V DC (max.) 1 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.2 2.4 4.0 4.8 7.2 9.6 19.2 38.6 2, 4 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 Drop-out voltage, V DC (min.) 0.15 0.3 0.5 0.6 0.9 1.2 2.4 4.8 0.15 0.3 0.5 0.6 0.9 1.2 2.4 4.8 Coil resistance, Ω (±10%) 5.63 22.5 62.5 90 203 360 1440 5760 11.3 45 125 180 405 720 2880 11520 Maximum allowable, V DC (at 50°C 122°F) 1 Form C 2, 4 Form C 1.8 2.25 3.6 4.5 6 7.5 7.2 9 10.8 13.5 14.4 18 28.8 36 57.6 72 2.4 3 4.8 6 8.0 10 9.6 12 14.4 18 19.2 24 28.4 48 76.8 96 1 coil latching Nominal voltage, V DC 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 M type S type Reset Set, V DC (max.) 1 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.2 2.4 4.0 4.8 7.2 9.6 19.2 38.4 Coil resistance, Ω (±10%) 2, 4 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 12.5 50 139 200 450 800 3200 12800 25 100 278 400 900 1600 6400 25600 Maximum allowable, V DC (at 50°C 122°F) 1 Form C 2, 4 Form C 1.8 2.25 3.6 4.5 6 7.5 7.2 9 10.8 13.5 14.4 18 28.8 36 57.6 72 2.4 3 4.8 6 8.0 10 9.6 12 14.4 18 19.2 24 38.4 48 76.8 96 2 coil latching Nominal voltage, V DC M type S type 188 1.5 3 5 6 9 12 24 48 1.5 3 5 6 9 12 24 48 Reset Set, V DC (max.) 1 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.2 2.4 4.0 4.8 7.2 9.6 19.2 38.4 2,4 Form C 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 1.05 2.1 3.5 4.2 6.3 8.4 16.8 33.6 Coil resistance, Ω (±10%) Coil l Coil ll 6.25 25 69.4 100 225 400 1600 6400 12.5 50 139 200 450 800 3200 12800 Maximum allowable, V DC (at 50°C 122°F) 1 Form C 2,4 Form C 1.8 2.25 3.6 4.5 6 7.5 7.2 9 10.8 13.5 14.4 18 28.8 36 57.6 72 2.4 3 4.8 6 8.0 10 9.6 12 14.4 18 19.2 24 38.4 48 76.8 96 DS DIMENSIONS mm inch 1 Form C PC board pattern (Copper-side view) Single side stable, 1 coil latching 2 coil latching Single side stable, 1 coil latching, 2 coil latching 15 .590 15 .590 5-0.9 dia 5-.035 dia 9.9 .390 9.3 9.9 .366 .340 2.54 .100 0.6 .024 3.4 .134 5.08 .200 7.62 .300 0.6 .024 5.08 .200 7.62 .300 6-0.9 dia 6-.035 dia 2.54 .100 2.54 .100 7.62 .300 7.62 .300 5.6 .221 0.6 .024 2.54 .100 Tolerance: ±0.1 ± .004 7.62 .300 General tolerance: ±0.3 ±.012 Schematic (Bottom view) Single side stable Deenergized condition 1 + 1 coil latching 1 – 6 – 2 coil latching 6 + 1 + 3 – 6 + SET RST SET RST 12 10 N.O. N.C. COM 12 10 7 • A polarity bar showing the relay direction can replace the schematic. SET RST 12 10 COM 7 Diagram shows the "reset" position when terminals 1 and 6 are energized. Energize with reverse polarity to transfer contacts. 2 Form C COM 7 Diagram shows the "reset" position when terminals 3 and 6 are energized. Energize terminals 1 and 3 to transfer contacts. PC board pattern (Copper-side view) Single side stable, 1 coil latching 2 coil latching Single side stable, 1 coil latching, 2 coil latching 8-0.9 dia 8-.035 dia 9.9 .390 20 .787 20 .787 9.3 9.9 .366 .340 2.54 .100 0.6 .024 3.4 .134 5.08 5.08 .200 .200 0.6 .024 0.6 .024 7.62 .300 5.08 5.08 5.08 .200 .200 .200 2.54 .100 10-0.9 dia 10-.035 dia 2.54 .100 7.62 .300 2.54 .100 2.54 .100 7.62 .300 matching 16 pin IC socket 5.6 .221 Tolerance: ±0.1 ± .004 7.62 .300 General tolerance: ±0.3 ±.012 16 – N.O. N.C. COM + 8 6 4 1 • A polarity bar showing the relay direction can replace the schematic. 9 11 13 SET RST COM 16 + 9 11 13 15 16 SET RST COM – – SET RST COM 8 6 4 – 1 SET RST COM + + 8 6 4 2 1 Diagram shows the "reset" position when terminals 1 and 16 are energized. Energize with reverse polarity to transfer contacts. Set 9 11 13 N.O. N.C. COM 2 coil latching 1 coil latching Reset Schematic (Bottom view) Single side stable Deenergized condition Diagram shows the "reset" position when terminals 2 and 15 are energized. Energize terminals 1 and 16 to transfer contacts. 189 DS mm inch 4 Form C Single side stable, 1 coil latching, 2 coil latching 35.24 1.387 35.24 1.387 9.9 .390 9.3 9.9 .366 .340 0.6 .024 3.4 .134 5.08 5.08 .200 .200 7.62 .300 5.08 5.08 5.08 .200 .200 .200 0.6 .024 5.08 5.08 5.08 5.08 5.08 5.08 .200 .200 .200 2.54.200 .200 .200 .100 0.6 .024 5.6 .221 7.62 .300 General tolerance: ±0.3 ±.012 PC board pattern (Copper-side view) Single side stable, 1 coil latching 14-0.9 dia 14-.035 dia 2.54 .100 2 coil latching 16-0.9 dia 16-.035 dia 2.54 .100 2.54 .100 7.62 .300 2.54 .100 7.62 .300 2.54 × 2 2.54 × 2 2.54 × 3 2.54 × 2 2.54 × 2 2.54 × 2 .100 × 2 .100 × 2 .100 × 3 .100 × 2 .100 × 2 .100 × 2 2.54 × 2 2.54 × 2 2.54 × 2 2.54 2.54 × 2 2.54 × 2 2.54 × 2 .100 × 2 .100 × 2 .100 × 2 .100 .100 × 2 .100 × 2 .100 × 2 Tolerance: ±0.1 ± .004 N.O. N.C. COM + COM N.C. N.O. 8 6 4 1 3 5 7 • A polarity bar showing the relay direction can replace the schematic. 2 coil latching 9 11 13 16 14 12 10 SET RST COM – COM RST SET 9 11 13 1516 14 12 10 SET RST COM – – COM RST SET SET RST COM + COM RST SET 8 6 4 1 3 5 7 SET RST COM + + COM RST SET 8 6 4 2 1 3 5 7 Set 9 11 13 16 14 12 10 N.O. N.C. COM – COM N.C. N.O. 1 coil latching Reset Schematic (Bottom view) Single side stable Deenergized condition Diagram shows the "reset" position when terminals 1 and 16 are energized. Energize with reverse polarity to transfer contacts. Diagram shows the "reset" position when terminals 2 and 15 are energized. Energize terminals 1 and 16 to transfer contacts. 2. Life curve (Resistive load) 3. Contact reliability for AC loads REFERENCE DATA 1. Maximum switching capacity 10 10V 2.0 1.0 0.5 190 100mA 1A Switching current 0 1 2 Switching current, A 0.1 VA C 125V AC Weibull probability data 0.2 10mV 10µA 250 5.0 125 V DC 0.5A 10.0 0.3A 100 70.0 50.0 30.0 0.5 100V 30 V DC 99.9 99.0 95.0 1 A 2 A 12 50V 5V AC AC 1,000 No. of operations, ×104 Contact voltage 1,000V F(t), % Sample: DS2E-M-DC24V 10 pcs. Cycle rate: 20 cpm. Detection level: 200 mΩ 0 10 100 No. of operations, ×104 1,000 DS 4-(1). Coil termperature rise 4-(2). Coil tempeature rise 4-(3). Coil temperature rise (2 Form C single side stable type) Point measured: Inside the coil Ambient temperature: 18° to 19°C 64° to 66°F (4 Form C single side stable type) Point measured: Inside the coil Ambient temperature: 17° to 18°C 63° to 64°F (2 Form C 2 coil latching type) Point measured: Inside the coil Ambient temperature: 20° to 21°C 68° to 70°F 0A 40 30 Temperature rise, °C 3A 2A 50 60 60 3A Temperature rise, °C Temperature rise, °C 60 50 3A 40 2A 30 0A 50 2A 40 0A 30 20 20 20 10 10 10 0 100 0 110 Coil applied voltage, %V 100 0 110 Coil applied voltage, %V Reset coil Set coil 100 110 Coil applied voltage, %V 5. Operate and release time characteristics 6-(1). Influence of adjuacent mounting (4 Form C 2 coil latching type) Point measured: Inside the coil Ambient temperature: 20°C 68°F (2 Form C single side stable type) Test condition: Without diode connected to coil in parallel (1 Form C) 4 2A 40 0A 30 20 Reset coil Set coil 10 0 100 3 Operate time (mean) 2 Release time (mean) 1 0 110 Coil applied voltage, %V 80 (4 Form C) OFF OFF 0 ON ON –10 10 0 Drop-out voltage OFF OFF 60 40 OFF ON 20 0 OFF OFF –20 ON ON ON ON 10 Drop-out voltage OFF OFF 0 ON ON –10 60 (1) (2) (3) 40 OFF OFF ON ON OFF OFF ON ON Drop-out voltage 20 0 –20 –60 –80 –80 5 10 .197 .394 Inter-relay distance , mm inch OFF –10 ON –60 –10 OFF –40 –40 ON (1) (2) (3) 0 80 OFF Pick-up voltage ON Pick-up voltage 5 10 .197 .394 Inter-relay distance , mm inch (1) (2) (3) 80 (1) (2) (3) Rete of change, % Rete of change, % Rete of change, % 6-(3). Influence of adjacent mounting (2 Form C) Pick-up voltage 10 100 120 Coil applied voltage, % 6-(2). Influence of adjacent mounting 10 Rete of change, % 50 Rete of change, % 3A Operate and release time, ms Temperature rise, °C 60 Rete of change, % 4-(4). Coil temperature rise 10 20 .394 .787 Inter-relay distance , mm inch 10 20 .394 .787 Inter-relay distance , mm inch For Cautions for Use, see Relay Technical Information 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, 191 Ltd.