AD ADuM3190TRQZ-RL7 High stability isolated error amplifier Datasheet

High Stability Isolated Error Amplifier
ADuM3190
Data Sheet
FEATURES
GENERAL DESCRIPTION
Stability in isolated feedback applications
0.5% initial accuracy
1% accuracy over the full temperature range
Compatible with Type II or Type III compensation networks
Reference voltage: 1.225 V
Compatible with DOSA
Low power operation: <7 mA total
Wide voltage supply range
VDD1: 3 V to 20 V
VDD2: 3 V to 20 V
Bandwidth: 400 kHz
Isolation voltage: 2.5 kV rms
Safety and regulatory approvals
UL recognition: 2500 V rms for 1 minute per UL 1577
CSA Component Acceptance Notice #5A
VDE certificate of conformity
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12
VIORM = 565 V peak
Wide temperature range
−40°C to +125°C ambient operation
150°C maximum junction temperature
Qualified for automotive applications
The ADuM31901 is an isolated error amplifier based on Analog
Devices, Inc., iCoupler® technology. The ADuM3190 is ideal for
linear feedback power supplies. The primary side controllers of
the ADuM3190 enable improvements in transient response,
power density, and stability as compared to commonly used
optocoupler and shunt regulator solutions.
Unlike optocoupler-based solutions, which have an uncertain
current transfer ratio over lifetime and at high temperatures, the
ADuM3190 transfer function does not change over its lifetime,
and it is stable over a wide temperature range of −40°C to +125°C.
Included in the ADuM3190 is a wideband operational amplifier
for a variety of commonly used power supply loop compensation
techniques. The ADuM3190 is fast enough to allow a feedback
loop to react to fast transient conditions and overcurrent conditions. Also included is a high accuracy 1.225 V reference to
compare with the supply output setpoint.
The ADuM3190 is packaged in a small 16-lead QSOP package
for a 2.5 kV rms isolation voltage rating.
APPLICATIONS
Linear power supplies
Inverters
Uninterruptible Power Supply (UPS)
DOSA-compatible modules
Voltage monitors
Automotive systems
VDD1 1
16
VDD2
GND1 2
15
GND2
14
VREG2
13
REFOUT
12
+IN
11
–IN
EAOUT 7
10
COMP
GND1 8
9
GND2
VREG1 3
REFOUT1 4
REG
UVLO
UVLO
REF
REF
NC 5
EAOUT2 6
REG
Tx
Rx
11335-001
FUNCTIONAL BLOCK DIAGRAM
Figure 1.
1
Protected by U.S. Patents 5,952,849, 6,873,065 and 7,075,329. Other patents pending.
Rev. A
Document Feedback
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700 ©2013–2015 Analog Devices, Inc. All rights reserved.
Technical Support
www.analog.com
ADUM3190* Product Page Quick Links
Last Content Update: 11/01/2016
Comparable Parts
Reference Materials
View a parametric search of comparable parts
Press
• Analog Devices Achieves Major Milestone by Shipping 1
Billionth Channel of iCoupler Digital Isolation
• Isolated Error Amplifiers Outperform Optocouplers and
Shunt Regulators in Power Supply Applications
Technical Articles
• MS-2501: Isolated Error Amplifier Replaces Optocoupler
and Shunt Regulator for AC/DC and DC/DC Power
• MS-2727: Optimizing Multiple Output Power Converters
Evaluation Kits
• ADUM3190 Evaluation Board
Documentation
Application Notes
• AN-1316: Generating Multiple Isolated Bias Rails for
IGBT Motor Drives with Flyback, SEPIC, and Ćuk
Combination
Data Sheet
• ADuM3190: High Stability Isolated Error Amplifier Data
Sheet
User Guides
• UG-534: iCoupler ADuM3190 Isolated Error Amplifier
Evaluation Board
Reference Designs
Design Resources
•
•
•
•
ADUM3190 Material Declaration
PCN-PDN Information
Quality And Reliability
Symbols and Footprints
Discussions
View all ADUM3190 EngineerZone Discussions
• CN0342
Sample and Buy
Visit the product page to see pricing options
Technical Support
Submit a technical question or find your regional support
number
* This page was dynamically generated by Analog Devices, Inc. and inserted into this data sheet. Note: Dynamic changes to
the content on this page does not constitute a change to the revision number of the product data sheet. This content may be
frequently modified.
ADuM3190
Data Sheet
TABLE OF CONTENTS
Features .............................................................................................. 1
Typical Performance Characteristics ..............................................9
Applications ....................................................................................... 1
Test Circuits..................................................................................... 13
General Description ......................................................................... 1
Applications Information .............................................................. 14
Functional Block Diagram .............................................................. 1
Theory of Operation .................................................................. 14
Revision History ............................................................................... 2
Accuracy Circuit Operation...................................................... 14
Specifications..................................................................................... 3
Isolated Amplifier Circuit Operation ...................................... 14
Package Characteristics ............................................................... 5
Application Block Diagram ...................................................... 15
Regulatory Information ............................................................... 5
Setting the Output Voltage ........................................................ 15
Insulation and Safety Related Specifications ............................ 5
DOSA Module Application....................................................... 15
Recommended Operating Conditions ...................................... 5
DC Correctness and Magnetic Field Immunity .......................... 16
DIN V VDE V 0884-10 (VDE V 0884-10) Insulation
Characteristics .............................................................................. 6
Insulation Lifetime ..................................................................... 17
Packaging and Ordering Information ......................................... 18
Absolute Maximum Ratings ....................................................... 7
Outline Dimensions ................................................................... 18
ESD Caution .................................................................................. 7
Ordering Guide .......................................................................... 18
Pin Configuration and Function Descriptions ............................. 8
Automotive Products ................................................................. 18
REVISION HISTORY
7/15—Rev. 0 to Rev. A
Added W Models ................................................................ Universal
Changes to Features Section and Applications Section ............... 1
Changes to Table 1 ............................................................................ 3
Changes to Regulatory Information Section and Table 3 ........... 5
Changes to DIN V VDE V 0884-10 (VDE V 0884-10)
Insulation Characteristics Section and Table 6............................. 6
Change to AC Voltage, Bipolar Parameter, Table 8 ...................... 7
Changes to Figure 12 and Figure 14............................................. 10
Added Figure 16 to Figure 24; Renumbered Sequentially ........ 11
Deleted Figure 24; Renumbered Sequentially ............................ 13
Added Isolated Amplifier Circuit Operation Section................ 14
Changes to Applications Block Diagram Section....................... 15
Updated Outline Dimensions ....................................................... 18
Changes to Ordering Guide .......................................................... 18
Added Automotive Products Section........................................... 18
2/13—Revision 0: Initial Version
Rev. A | Page 2 of 18
Data Sheet
ADuM3190
SPECIFICATIONS
VDD1 = VDD2 = 3 V to 20 V for TA = TMIN to TMAX. All typical specifications are at TA = 25°C and VDD1 = VDD2 = 5 V, unless otherwise noted.
Table 1.
Parameter
ACCURACY
Initial Error
Total Error
OP AMP
Offset Error
Open-Loop Gain
Input Common-Mode Range
Gain Bandwidth Product
Common-Mode Rejection
Input Capacitance
Output Voltage Range
Input Bias Current
REFERENCE
Output Voltage
Output Current
UVLO
Positive Going Threshold
Negative Going Threshold
EAOUT Impedance
OUTPUT CHARACTERISTICS
Output Gain1
A, B, S, and T Grades
WS and WT Grades
Output Offset Voltage
Output Linearity2
Output −3 dB Bandwidth
A, S, and WS Grades
B, T, and WT Grades
Output Voltage, EAOUT
Low Voltage
High Voltage
Output Voltage, EAOUT2
Low Voltage
High Voltage
Noise, EAOUT
Noise, EAOUT2
Test Conditions/Comments
(1.225 V − EAOUT)/1.225 V × 100%; see Figure 27
TA = 25°C
TA = TMIN to TMAX
Min
−5
66
0.35
Typ
Max
Unit
0.25
0.5
0.5
1
%
%
±2.5
80
+5
mV
dB
V
MHz
dB
pF
V
µA
1.5
10
72
2
COMP pin
0.2
2.7
0.01
0 mA to 1 mA load, CREFOUT = 15 pF
TA = 25°C
TA = TMIN to TMAX
CREFOUT = 15 pF
1.215
1.213
2.0
1.225
1.225
1.235
1.237
V
V
mA
2.8
2.6
High-Z
2.96
2.4
V
V
Ω
0.9
2.34
1.0
2.6
1.1
2.86
V/V
V/V
0.83
2.5
1.0
2.6
1.17
2.7
V/V
V/V
−0.2
−0.1
+0.05
+0.01
+0.2
+0.1
V
V
−1.0
−1.0
+0.15
+0.1
+1.0
+1.0
%
%
100
250
200
400
2.4
2.7
4.8
5.0
0.3
0.3
4.9
5.4
1.7
4.8
VDD2 or VDD1 < UVLO threshold
See Figure 29
From COMP to EAOUT, 0.4 V to 2.1 V, ±3 mA
From EAOUT to EAOUT2, 0.4 V to 2.1 V, ±1 mA,
VDD1 = 20 V
From COMP to EAOUT, 0.4 V to 2.1 V, ±3 mA
From EAOUT to EAOUT2, 0.4 V to 2.1 V, ±1 mA,
VDD1 = 20 V
From COMP to EAOUT, 0.4 V to 2.1 V, ±3 mA
From EAOUT to EAOUT2, 0.4 V to 2.1 V, ±1 mA,
VDD1 = 20 V
From COMP to EAOUT, 0.4 V to 2.1 V, ±3 mA
From EAOUT to EAOUT2, 0.4 V to 2.1 V, ±1 mA,
VDD1 = 20 V
From COMP to EAOUT, 0.4 V to 2.1 V, ±3 mA,
and from COMP to EAOUT2, 0.4 V to 2.1 V,
±1 mA, VDD1 = 20 V
kHz
kHz
±3 mA output
±1 mA output
VDD1 = 4.5 V to 5.5 V
VDD1 = 10 V to 20 V
VDD1 = 4.5 V to 5.5 V
VDD1 = 10 V to 20 V
See Figure 15
See Figure 15
Rev. A | Page 3 of 18
0.4
V
V
0.6
0.6
V
V
V
V
mV rms
mV rms
ADuM3190
Parameter
POWER SUPPLY
Operating Range, Side 1
Operating Range, Side 2
Power Supply Rejection
Supply Current
IDD1
IDD2
1
2
Data Sheet
Test Conditions/Comments
Min
VDD1
VDD2
DC, VDD1 = VDD2 = 3 V to 20 V
3.0
3.0
60
See Figure 4
See Figure 5
Typ
1.4
2.9
Max
Unit
20
20
V
V
dB
2.0
5.0
mA
mA
Output gain is defined as the slope of the best-fit line of the output voltage vs. the input voltage over the specified input range, with the offset error adjusted out.
Output linearity is defined as the peak-to-peak output deviation from the best-fit line of the output gain, expressed as a percentage of the full-scale output voltage.
Rev. A | Page 4 of 18
Data Sheet
ADuM3190
PACKAGE CHARACTERISTICS
Table 2.
Parameter
RESISTANCE
Input-to-Output1
CAPACITANCE
Input-to-Output1
Input Capacitance2
IC JUNCTION-TO-AMBIENT THERMAL
RESISTANCE
16-Lead QSOP
1
2
Symbol
Min
Typ
Max
Unit
RI-O
1013
Ω
CI-O
CI
2.2
4.0
pF
pF
Test Conditions/Comments
f = 1 MHz
Thermocouple located at center of package underside
θJA
76
°C/W
The device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM3190 is approved by the organizations listed in Table 3. See Table 8 and the Insulation Lifetime section for recommended
maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 3.
UL
Recognized Under 1577 Component
Recognition Program1
Single Protection, 2500 V rms Isolation
Voltage, 16-Lead QSOP
File E214400
1
2
CSA
Approved under CSA Component
Acceptance Notice #5A
Basic insulation per CSA 60950-1-03 and
IEC 60950-1, 400 V rms (565 V peak)
maximum working voltage
File 205078
VDE
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10): 2006-122
Reinforced insulation, 565 V peak
File 2471900-4880-0001
In accordance with UL 1577, each ADuM3190 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 sec (current leakage detection limit = 5 µA).
In accordance with DIN V VDE V 0884-10, each ADuM3190 is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The asterisk (*) marked on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 4.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Symbol
L(I01)
Value
2500
3.8 min
Unit
V rms
mm
Minimum External Tracking (Creepage)
L(I02)
3.1 min
mm
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
CTI
0.017 min
>400
II
mm
V
Test Conditions/Comments
1-minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303, Part 1
Material Group DIN VDE 0110, 1/89, Table 1
RECOMMENDED OPERATING CONDITIONS
Table 5.
Parameter
OPERATING TEMPERATURE BY MODEL
ADuM3190A/ADuM3190B
ADuM3190S/ADuM3190T
SUPPLY VOLTAGES1
INPUT SIGNAL RISE AND FALL TIMES
1
Symbol
TA
VDD1, VDD2
tR , tF
All voltages are relative to their respective grounds.
Rev. A | Page 5 of 18
Min
Max
Unit
−40
−40
3.0
+85
+125
20
1.0
°C
°C
V
ms
ADuM3190
Data Sheet
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced isolation only within the safety limit data. Maintenance of the safety data is ensured by protective
circuits. The asterisk (*) marking branded on the package denotes DIN V VDE V 0884-10 approval for a 565 V peak working voltage.
Table 6.
Description
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Test Conditions/Comments
VIORM × 1.875 = Vpd(m), 100% production test,
tini = tm = 1 sec, partial discharge < 5 pC
Input-to-Output Test Voltage, Method A
After Environmental Tests Subgroup 1
VIORM × 1.5 = Vpd(m), tini = 60 sec,
tm = 10 sec, partial discharge < 5 pC
VIORM × 1.2 = Vpd(m), tini = 60 sec,
tm = 10 sec, partial discharge < 5 pC
After Input and/or Safety Test Subgroup 2
and Subgroup 3
Highest Allowable Overvoltage
Surge Isolation Voltage
Safety Limiting Values
VPEAK = 10 kV; 1.2 µs rise time; 50 µs, 50% fall time
Maximum value allowed in the event of a failure
(see Figure 2)
Case Temperature
Safety Total Dissipated Power
Insulation Resistance at TS
VIO = 500 V
Symbol
Characteristic
Unit
VIORM
Vpd(m)
I to IV
I to III
I to II
40/105/21
2
565
1059
V peak
V peak
Vpd(m)
848
V peak
Vpd(m)
678
V peak
VIOTM
VIOSM
4000
6250
V peak
V peak
TS
PS
RS
150
1.64
>109
°C
W
Ω
1.8
SAFE LIMITING POWER (W)
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0
0
50
100
150
AMBIENT TEMPERATURE (°C)
200
11335-004
0.2
Figure 2. Thermal Derating Curve, Dependence of Safety Limiting Values on Case
Temperature, per DIN V VDE V 0884-10
Rev. A | Page 6 of 18
Data Sheet
ADuM3190
ABSOLUTE MAXIMUM RATINGS
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
TA = 25°C, unless otherwise noted.
Table 7.
Parameter
Storage Temperature (TST) Range
Ambient Operating Temperature
(TA) Range
Junction Temperature
Supply Voltages
VDD1, VDD21
VREG1, VREG21
Input Voltages (+IN, −IN)
Output Voltages
REFOUT, COMP, REFOUT1, EAOUT
EAOUT2
Output Current per Output Pin
Common-Mode Transients2
1
2
Rating
−65°C to +150°C
−40°C to +125°C
−40°C to +150°C
Table 8. Maximum Continuous Working Voltage1
−0.5 V to +24 V
−0.5 V to +3.6 V
−0.5 V to +3.6 V
−0.5 V to +3.6 V
−0.5 V to +5.5 V
−11 mA to +11 mA
−100 kV/µs to +100 kV/µs
All voltages are relative to their respective grounds.
Refers to common-mode transients across the insulation barrier. Commonmode transients exceeding the absolute maximum ratings may cause
latch-up or permanent damage.
Parameter
WAVEFORM
AC Voltage
Bipolar
Unipolar
DC Voltage
1
Max
Unit
Constraint
565
1131
1131
V peak
V peak
V peak
50-year minimum lifetime
50-year minimum lifetime
50-year minimum lifetime
Refers to continuous voltage magnitude imposed across the isolation
barrier. See the Insulation Lifetime section for more details.
ESD CAUTION
Rev. A | Page 7 of 18
ADuM3190
Data Sheet
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
1
16 VDD2
2
15 GND2
14 VREG2
VREG1
3
REFOUT1
4
ADuM3190
13 REFOUT
NC
5
TOP VIEW
(Not to Scale)
12 +IN
EAOUT2
6
11 –IN
EAOUT
7
10 COMP
GND1
8
9
GND2
NC = NO CONNECTION. CONNECT PIN 5 TO GND1;
DO NOT LEAVE THIS PIN FLOATING.
11335-005
VDD1
Figure 3. Pin Configuration
Table 9. Pin Function Descriptions
Pin No.
1
2
3
4
5
6
Mnemonic
VDD1
GND1
VREG1
REFOUT1
NC
EAOUT2
7
8
9
10
11
12
13
14
15
16
EAOUT
GND1
GND2
COMP
−IN
+IN
REFOUT
VREG2
GND2
VDD2
Description
Supply Voltage for Side 1 (3.0 V to 20 V). Connect a 1 μF capacitor between VDD1 and GND1.
Ground Reference for Side 1.
Internal Supply Voltage for Side 1. Connect a 1 μF capacitor between VREG1 and GND1.
Reference Output Voltage for Side 1. The maximum capacitance for this pin (CREFOUT1) must not exceed 15 pF.
No Connection. Connect Pin 5 to GND1; do not leave this pin floating.
Isolated Output Voltage 2, Open-Drain Output. Connect a pull-up resistor between EAOUT2 and VDD1 for current up to
1 mA.
Isolated Output Voltage.
Ground Reference for Side 1.
Ground Reference for Side 2.
Output of the Op Amp. A loop compensation network can be connected between the COMP pin and the −IN pin.
Inverting Op Amp Input. Pin 11 is the connection for the power supply setpoint and compensation network.
Noninverting Op Amp Input. Pin 12 can be used as a reference input.
Reference Output Voltage for Side 2. The maximum capacitance for this pin (CREFOUT) must not exceed 15 pF.
Internal Supply Voltage for Side 2. Connect a 1 μF capacitor between VREG2 and GND2.
Ground Reference for Side 2.
Supply Voltage for Side 2 (3.0 V to 20 V). Connect a 1 μF capacitor between VDD2 and GND2.
Rev. A | Page 8 of 18
Data Sheet
ADuM3190
TYPICAL PERFORMANCE CHARACTERISTICS
3
1.228
VDDx = 20V
VDDx = 5V
REFOUT ACCURACY (V)
1.227
IDD1 (mA)
2
1
1.226
1.225
1.224
–20
0
20
40
60
80
100
120
140
TEMPERATURE (°C)
1.222
–40
11335-017
0
–40
0
20
40
60
80
100
120
140
TEMPERATURE (°C)
Figure 4. Typical IDD1 Supply Current vs. Temperature
5
–20
11335-020
1.223
Figure 7. REFOUT Accuracy vs. Temperature
1.0
VDDx = 20V
VDDx = 5V
EAOUT ACCURACY (%)
IDD2 (mA)
4
3
2
0.5
0
–0.5
0
20
40
60
80
100
120
140
TEMPERATURE (°C)
–1.0
–40
2
OP AMP OFFSET VOLTAGE (mV)
10
8
6
4
2
20
40
60
80
100
120
TEMPERATURE (°C)
140
40
60
80
100
120
140
120
140
1
0
–1
–2
–3
–40
11335-019
INPUT BIAS CURRENT (nA)
3
0
20
Figure 8. EAOUT Accuracy vs. Temperature
12
–20
0
TEMPERATURE (°C)
Figure 5. Typical IDD2 Supply Current vs. Temperature
0
–40
–20
–20
0
20
40
60
80
100
TEMPERATURE (°C)
Figure 6. +IN, −IN Input Bias Current vs. Temperature
Figure 9. Op Amp Offset Voltage vs. Temperature
Rev. A | Page 9 of 18
11335-022
–20
11335-018
0
–40
11335-021
1
Data Sheet
0
90
–20
EAOUT OFFSET (mV)
100
80
70
60
–40
–60
–20
0
20
40
60
80
100
120
140
TEMPERATURE (°C)
–100
–40
20
40
60
80
100
120
140
Figure 13. EAOUT Offset Voltage vs. Temperature
1.05
100
EAOUT2 OFFSET VOLTAGE (mV)
1.04
EAOUT GAIN (V/V)
0
TEMPERATURE (°C)
Figure 10. Op Amp Open-Loop Gain vs. Temperature
1.03
1.02
–20
0
20
40
60
80
100
120
140
TEMPERATURE (°C)
11335-024
1.01
1.00
–40
–20
50
0
–50
–100
–40
–20
0
20
40
60
80
100
120
140
TEMPERATURE (°C)
Figure 11. EAOUT Gain vs. Temperature
Figure 14. EAOUT2 Offset Voltage vs. Temperature
2.66
2.64
2.62
2.60
2
2.56
–40
–20
0
20
40
60
80
100
TEMPERATURE (°C)
120
140
CH1 10mV Ω
CH2 10mV Ω
M4.0µs
A CH1
T
102.4ns
1.18V
Figure 15. Output Noise with Test Circuit 1 (10 mV/DIV),
Channel 1 = EAOUT, Channel 2 = EAOUT2
Figure 12. EAOUT2 Gain vs. Temperature
Rev. A | Page 10 of 18
11335-028
2.58
11335-025
EAOUT2 GAIN (V/V)
1
11335-027
50
–40
11335-026
–80
11335-023
OP AMP OPEN-LOOP GAIN (dB)
ADuM3190
ADuM3190
30
30
25
25
NUMBER OF AMPLIFIERS
20
15
10
5
15
10
0.95
1.00
1.05
1.10
COMP TO EAOUT GAIN (V/V)
0
–0.4
30
30
25
25
20
15
10
5
0.4
20
15
10
1.05
1.10
0
–0.4
–0.2
0
0.2
0.4
COMP TO EAOUT OFFSET VOLTAGE (V)
11335-120
1.00
11335-117
0.95
Figure 17. EAOUT Gain Distribution at 125°C
Figure 20. EAOUT Offset Voltage Distribution at 125°C
30
25
25
NUMBER OF AMPLIFIERS
30
20
15
10
5
20
15
10
5
0.95
1.00
1.05
COMP TO EAOUT GAIN (V/V)
1.10
11335-118
NUMBER OF AMPLIFIERS
0.2
5
COMP TO EAOUT GAIN (V/V)
0
0.90
0
Figure 19. EAOUT Offset Voltage Distribution at 25°C
NUMBER OF AMPLIFIERS
NUMBER OF AMPLIFIERS
Figure 16. EAOUT Gain Distribution at 25°C
0
0.90
–0.2
COMP TO EAOUT OFFSET VOLTAGE (V)
11335-119
5
11335-116
0
0.90
20
Figure 18. EAOUT Gain Distribution at −40°C
0
–0.4
–0.2
0
0.2
COMP TO EAOUT OFFSET VOLTAGE (V)
Figure 21. EAOUT Offset Voltage Distribution at −40°C
Rev. A | Page 11 of 18
0.4
11335-121
NUMBER OF AMPLIFIERS
Data Sheet
ADuM3190
Data Sheet
30
NUMBER OF AMPLIFIERS
25
20
15
1
10
5
1.225
1.230
1.235
EAOUT ACCURACY (V)
11335-122
3
1.220
Figure 22. EAOUT Accuracy Voltage Distribution at 25°C
CH1 100mV Ω CH2 100mV Ω
CH3 200mV Ω
M2µs
T
0s
A CH1
434mV
11335-029
2
0
1.215
Figure 25. Output 100 kHz Signal with Test Circuit 3, Channel 1 = +IN,
Channel 2 = EAOUT, Channel 3 = EAOUT2
30
NUMBER OF AMPLIFIERS
25
20
2
1
15
3
10
1.220
1.225
1.230
1.235
EAOUT ACCURACY (V)
30
20
15
10
5
1.225
1.230
1.235
EAOUT ACCURACY (V)
11335-124
NUMBER OF AMPLIFIERS
25
1.220
CH2 50mV Ω
M2µs
A CH1
T
5.92µs
399mV
Figure 26. Output Square Wave Response with Test Circuit 3,
Channel 1 = +IN, Channel 2 = EAOUT, Channel 3 = EAOUT2
Figure 23. EAOUT Accuracy Voltage Distribution at 125°C
0
1.215
CH1 20mV Ω
CH3 20mV Ω
Figure 24. EAOUT Accuracy Voltage Distribution at −40°C
Rev. A | Page 12 of 18
11335-030
0
1.215
11335-123
5
Data Sheet
ADuM3190
TEST CIRCUITS
VDD1
1µF
GND1
1µF
VREG1
1
16
2
15
REG
3
REFOUT1 4
UVLO
UVLO
REF
REF
NC 5
GND2
1µF
VREG2
1µF
REFOUT
13
12
Tx
EAOUT2 6
EAOUT
11
Rx
7
10
8
9
+IN
–IN
680Ω
COMP
2.2nF
GND2
11335-002
GND1
14
REG
VDD2
Figure 27. Test Circuit 1: Accuracy Circuit Using EAOUT
VDD1
1µF
GND1
1µF
VREG1
1
16
2
15
REG
3
REFOUT1 4
ROD
UVLO
REF
12
11
Rx
GND2
1µF
VREG2
1µF
REFOUT
13
Tx
6
7
10
8
9
+IN
–IN
680Ω
COMP
2.2nF
GND2
11335-003
GND1
14
REG
REF
NC 5
EAOUT2
EAOUT
UVLO
VDD2
Figure 28. Test Circuit 2: Accuracy Circuit Using EAOUT2
GND1
1µF
VREG1
ROD
1
16
2
15
REG
3
REFOUT1 4
UVLO
EAOUT
GND1
6
14
REG
REF
REF
NC 5
EAOUT2
UVLO
12
11
7
10
8
9
Figure 29. Test Circuit 3: Isolated Amplifier Circuit
Rev. A | Page 13 of 18
GND2
1µF
VREG2
1µF
13 REFOUT
Tx
Rx
VDD2
+IN
–IN
COMP
GND2
11335-031
VDD1
1µF
ADuM3190
Data Sheet
APPLICATIONS INFORMATION
THEORY OF OPERATION
In the test circuits of the ADuM3190 (see Figure 27 through
Figure 29), external supply voltages from 3 V to 20 V are
provided to the VDD1 and VDD2 pins, and internal regulators
provide 3.0 V to operate the internal circuits of each side of the
ADuM3190. An internal precision 1.225 V reference provides
the reference for the ±1% accuracy of the isolated error amplifier.
UVLO circuits monitor the VDDx supplies to turn on the internal
circuits when the 2.8 V rising threshold is met and to turn off
the error amplifier outputs to a high impedance state when VDDx
falls below 2.6 V.
approximately 100 kHz, but the circuit is more stable with a
phase shift of approximately −120°, which yields a stable 60°
phase margin.
This circuit is used for accuracy tests only, not for real-world
applications, because it has a 680 Ω resistor across the isolation
barrier to close the loop for the error amplifier; this resistor
causes leakage current to flow across the isolation barrier. For
this test circuit only, GND1 must be connected to GND2 to create a
return for the leakage current created by the 680 Ω resistor
connection.
AMPLITUDE (dB)
The op amp on the right side of the device has a noninverting
+IN pin and an inverting −IN pin available for connecting a
feedback voltage in an isolated dc-to-dc converter output, usually
through a voltage divider. The COMP pin is the op amp output,
which can be used to attach resistor and capacitor components in
a compensation network. The COMP pin internally drives the Tx
transmitter block, which converts the op amp output voltage
into an encoded output that is used to drive the digital isolator
transformer.
100
OP AMP AND
LINEAR ISOLATOR
OP AMP
ALONE
LINEAR ISOLATOR
POLE AT 400kHz
100
1k
10k
100k
1M
10M
FREQUENCY
(Hz)
LINEAR
ISOLATOR
PHASE (°)
100
1k
10k
100k
1M
10M
FREQUENCY
(Hz)
–90
On the left side of the ADuM3190, the transformer output
PWM signal is decoded by the Rx block, which converts the
signal into a voltage that drives an amplifier block; the amplifier
block produces the error amplifier output available at the EAOUT
pin. The EAOUT pin can deliver ±3 mA and has a voltage level
between 0.4 V and 2.4 V, which is typically used to drive the
input of a PWM controller in a dc-to-dc circuit.
11335-006
–180
Figure 30. Bode Plot 1
AMPLITUDE (dB)
OP AMP AND
LINEAR ISOLATOR
100
LINEAR ISOLATOR
POLE AT 400kHz
For applications that need more output voltage to drive their
controllers, Figure 28 illustrates the use of the EAOUT2 pin output,
which delivers up to ±1 mA with an output voltage of 0.6 V to 4.8 V
for an output that has a pull-up resistor to a 5 V supply. If the
EAOUT2 pull-up resistor connects to a 10 V to 20 V supply, the
output is specified to a minimum of 5.0 V to allow use with a
PWM controller requiring a minimum input operation of 5 V.
1k
10k
100k
1M
OP AMP
ALONE
FREQUENCY
(Hz)
10M
1k
10k
100k
1M
10M
INTEGRATOR
CONFIGURATION
100
PHASE (°)
100
FREQUENCY
(Hz)
–90
ACCURACY CIRCUIT OPERATION
See Figure 27 and Figure 28 for stability of the accuracy circuits.
The op amp on the right side of the ADuM3190, from the −IN
pin to the COMP pin, has a unity-gain bandwidth (UGBW) of
10 MHz. Figure 30, Bode Plot 1, shows a dashed line for the op
amp alone and its 10 MHz pole.
Figure 30 also shows the linear isolator alone (the blocks from
the op amp output to the ADuM3190 output, labeled as the
linear isolator), which introduces a pole at approximately
400 kHz. This total Bode plot of the op amp and linear isolator
shows that the phase shift is approximately −180° from the −IN
pin to the EAOUT pin before the crossover frequency. Because a
−180° phase shift can make the system unstable, adding an integrator configuration, as shown in the test circuits in Figure 27 and
Figure 28, consisting of a 2.2 nF capacitor and a 680 Ω resistor,
helps to make the system stable. In Figure 31, Bode Plot 2 with an
integrator configuration added, the system crosses over 0 dB at
11335-007
–180
Figure 31. Bode Plot 2
ISOLATED AMPLIFIER CIRCUIT OPERATION
Figure 29 shows an isolated amplifier circuit. In this circuit, the
input side amplifier is set as a unity-gain buffer so that the EAOUT
output follows the +IN input. The EAOUT2 output follows the
EAOUT output, but with a voltage gain of 2.6.
This circuit has an open-drain output, which must be pulled up
to a supply voltage from 3 V to 20 V using a resistor value set
for an output current of up to 1 mA. The EAOUT2 output can be
used to drive up to 1 mA to the input of a device that requires
a minimum input operation of 5 V. The EAOUT2 circuit has an
internal diode clamp to protect the internal circuits from
voltages greater than 5 V.
Rev. A | Page 14 of 18
Data Sheet
ADuM3190
The gain, offset, and linearity of EAOUT and EAOUT2 are specified
in Table 1 using this test circuit. When designing applications
for voltage monitoring using an isolated amplifier, review these
specifications, noting that the 1% accuracy specifications for the
isolated error amplifier do not apply. In addition, the EAOUT circuit
in Figure 29 is shown with an optional external RC low-pass filter
with a corner frequency of 500 kHz, which can reduce the 3 MHz
output noise from the internal voltage to the PWM converter.
APPLICATION BLOCK DIAGRAM
Figure 32 shows a typical application for the ADuM3190: an
isolated error amplifier in primary side control.
PWM CONTROLLER
FB COMP
LO
LATCHING
PWM
VOUT
DCR
POWER
STAGE
CO
CURRENT
SENSE
+
ESR
C1 COMPENSATION
NETWORK
COMP
R2
OP AMP
ADuM3190
1.225V
–IN
+IN
REFOUT
The 400 kHz bandwidth of the ADuM3190 error amplifier output
offers faster loop response for better transient response than the
typical shunt regulator and optocoupler solutions, which typically
have bandwidths of only 25 kHz to 50 kHz maximum.
11335-008
EAOUT2
C2
Figure 32. Application Block Diagram
The op amp of the ADuM3190 is used as the error amplifier for
the feedback of the output voltage, VOUT, using a resistor divider
to the −IN pin of the op amp. This configuration inverts the
output signal at the COMP pin when compared to the +IN pin,
which is connected to the internal 1.225 V reference.
SETTING THE OUTPUT VOLTAGE
The output voltage in the application circuit can be set with two
resistors in a voltage divider, as shown in Figure 33.
The output voltage is determined by the following equation
where VREF = 1.225 V.
For example, when the output voltage, VOUT, falls due to a load
step, the divider voltage at the −IN pin falls below the +IN reference voltage, causing the COMP pin output signal to go high.
The COMP output of the op amp is encoded and then decoded
by the digital isolator transformer block to a signal that drives the
output of the ADuM3190 high. The output of the ADuM3190
drives the COMP pin of the PWM controller, which is designed
to reset the PWM latch output to low only when its COMP pin is
low. A high at the COMP pin of the PWM controller causes the
latching PWM comparator to produce a PWM duty cycle output.
This PWM duty cycle output drives the power stage to increase
the VOUT voltage until it returns to regulation.
The power stage output is filtered by output capacitance and, in
some applications, by an inductor. Various elements contribute to
the gain and phase of the control loop and the resulting stability.
The output filter components (LO and CO) create a double pole;
the op amp has a pole at 10 MHz (see Figure 30), and the linear
isolator has a pole at 400 kHz (see Figure 30 and Figure 31).
The output capacitor and its ESR can add a zero at a frequency
that is dependent on the component type and values. With the
ADuM3190 providing the error amplifier, a compensation network
is provided from the −IN pin to the COMP pin to compensate
VOUT = VREF × (R1 + R2)/R2
(1)
VOUT
ISOLATED DC-TO-DC SUPPLY
R1
–IN
VIN = 0.35V TO 1.5V +IN
ERROR
AMP
VREF
1.225V
R2
REFOUT
ADuM3190
11335-010
ERROR
AMP
The ADuM3190 has two different error amplifier outputs:
EAOUT and EAOUT2. The EAOUT output, which can drive ±3 mA,
has a guaranteed maximum high output voltage of at least 2.4 V,
which may not be sufficient to drive the COMP pin of some
PWM controllers. The EAOUT2 pin can drive ±1 mA and has an
output range that guarantees 5.0 V for a VDD1 voltage range of
10 V to 20 V, which works well with the COMP pin of many
PWM controllers.
Figure 32 shows how to use the ADuM3190 to provide isolated
feedback in the control loop of an isolated dc-to-dc converter. In
this application block diagram, the loop is closed at approximately the 1.225 V reference voltage, providing ±1% accuracy
over temperature. The ADuM3190 op amp has a high gain bandwidth of 10 MHz to allow the dc-to-dc converter to operate at
high switching speeds, enabling smaller values for the output
filter components (LO and CO).
VIN
OSC
VREF
the control loop for stability. The compensation network values
depend on both the application and the components that are
selected; information about the component network values is
provided in the data sheet of the selected PWM controller.
Figure 33. Setting the Output Voltage
DOSA MODULE APPLICATION
Figure 34 is a block diagram of a Distributed-power Open
Standards Alliance (DOSA) circuit using the ADuM3190.
The block diagram shows how to use the ADuM3190 1.225 V
reference and the error amp in a DOSA standard power supply
module circuit to produce output voltage settings using a
combination of resistors.
The ADuM3190 1.225 V reference is specified for ±1% over the
−40°C to +125°C temperature range. See Table 10 to select the
resistor values to set the output voltage of the module. Two
different ranges of VOUT can be implemented, VOUT > 1.5 V or
VOUT < 1.5 V, depending on the required module.
Rev. A | Page 15 of 18
ADuM3190
Data Sheet
VOUT
OPTIONAL TRIM UP
OR TRIM DOWN
RESISTOR OR ±10%
OF NOMINAL VALUE
ACCORDING TO DOSA
R3
VREF
1.225V
R5
R4
100
RTRIM-DOWN
11335-011
R6
Figure 34. DOSA Module
Table 10. Resistor Values for DOSA Module
Module
Nominal Output
VOUT > 1.5 V
VOUT < 1.5 V
VOUT > 1.5 V
VOUT < 1.5 V
R3
1 kΩ
1 kΩ
5.11 kΩ
5.11 kΩ
R4
1 kΩ
0Ω
5.11 kΩ
0Ω
R5
0Ω
2.05 kΩ
0Ω
10.5 kΩ
R6
Open
1.96 kΩ
Open
10.0 kΩ
DC CORRECTNESS AND MAGNETIC FIELD IMMUNITY
Positive and negative logic transitions at the isolator input cause
narrow (~1 ns) pulses to be sent to the decoder via the transformer.
The decoder is bistable and is, therefore, either set or reset by
the pulses, indicating input logic transitions. In the absence of
logic transitions of more than 1 μs at the input, a periodic set of
refresh pulses indicative of the correct input state are sent to
ensure dc correctness at the output.
If the decoder receives no internal pulses for more than approximately 3 μs, the input side is assumed to be unpowered or
nonfunctional, in which case the isolator output is forced to
a default high impedance state by the watchdog timer circuit. In
addition, the outputs are in a default high impedance state while
the power is increasing before the UVLO threshold is crossed.
The ADuM3190 is immune to external magnetic fields. The limitation on the ADuM3190 magnetic field immunity is set by the
condition whereby induced voltage in the transformer receiving
coil is sufficiently large to either falsely set or reset the decoder.
The following analysis defines the conditions under which this
can occur. The 3 V operating condition of the ADuM3190 is
examined because it represents the most susceptible mode of
operation. The pulses at the transformer output have an amplitude
that is greater than 1.0 V. The decoder has a sensing threshold at
approximately 0.5 V, therefore establishing a 0.5 V margin within
which induced voltages are tolerated. The voltage induced across
the receiving coil is given by
2
V = (−dβ/dt) ∑π rn , n = 1, 2, … , N
10
1
0.1
0.01
0.001
1k
10k
100k
1M
10M
100M
MAGNETIC FIELD FREQUENCY (Hz)
11335-012
R2
ERROR
AMP
ADuM3190
RTRIM-UP
Figure 35. Maximum Allowable External Magnetic Flux Density
For example, at a magnetic field frequency of 1 MHz, the maximum allowable magnetic field of 0.02 kgauss induces a voltage
of 0.25 V at the receiving coil. This is approximately 50% of the
sensing threshold and does not cause a faulty output transition.
Similarly, if such an event were to occur during a transmitted
pulse (and had the worst-case polarity), the received pulse is
reduced from >1.0 V to 0.75 V, still well above the 0.5 V sensing
threshold of the decoder.
The preceding magnetic flux density values correspond to specific
current magnitudes at given distances away from the ADuM3190
transformers. Figure 36 shows these allowable current magnitudes
as a function of frequency for selected distances. As shown in
Figure 36, the ADuM3190 is immune and can be affected only by
extremely large currents operating at a high frequency very close
to the component. For the 1 MHz example, a 0.7 kA current
must be placed 5 mm away from the ADuM3190 to affect the
operation of the device.
1000
where:
β is the magnetic flux density (gauss).
rn is the radius of the nth turn in the receiving coil (cm).
N is the number of turns in the receiving coil.
DISTANCE = 1m
100
10
DISTANCE = 100mm
1
DISTANCE = 5mm
0.1
0.01
1k
10k
100k
1M
10M
MAGNETIC FIELD FREQUENCY (Hz)
Figure 36. Maximum Allowable Current for Various
Current-to-ADuM3190 Spacings
Rev. A | Page 16 of 18
100M
11335-013
VIN = 0.35V TO 1.5V
MAXIMUM ALLOWABLE MAGNETIC FLUX
DENSITY (kgauss)
R1
Given the geometry of the receiving coil in the ADuM3190 and
an imposed requirement that the induced voltage be, at most,
50% of the 0.5 V margin at the decoder, a maximum allowable
magnetic field is calculated, as shown in Figure 35.
MAXIMUM ALLOWABLE CURRENT (kA)
DOSA MODULE
Data Sheet
ADuM3190
The values shown in Table 8 summarize the peak voltage for
50 years of service life for a bipolar ac operating condition. In
many cases, the approved working voltage is higher than the
50-year service life voltage. Operation at these high working
voltages can lead to shortened insulation life in some cases.
The ADuM3190 insulation lifetime depends on the voltage waveform type imposed across the isolation barrier. The iCoupler
insulation structure degrades at different rates depending on
whether the waveform is bipolar ac, unipolar ac, or dc. Figure 37,
Figure 38, and Figure 39 illustrate these different isolation
voltage waveforms.
A bipolar ac voltage environment is the worst case for the iCoupler
products yet meets the 50-year operating lifetime recommended
by Analog Devices for maximum working voltage. In the case
of unipolar ac or dc voltage, the stress on the insulation is sig-
Rev. A | Page 17 of 18
RATED PEAK VOLTAGE
11335-014
Analog Devices performs accelerated life testing using voltage
levels higher than the rated continuous working voltage. Acceleration factors for several operating conditions are determined.
These factors allow calculation of the time to failure at the actual
working voltage.
Note that the voltage presented in Figure 38 is shown as sinusoidal for illustration purposes only. It is meant to represent any
voltage waveform varying between 0 V and some limiting value.
The limiting value can be positive or negative, but the voltage
cannot cross 0 V.
0V
Figure 37. Bipolar AC Waveform
RATED PEAK VOLTAGE
11335-015
All insulation structures eventually break down when subjected
to voltage stress over a sufficiently long period. The rate of insulation degradation is dependent on the characteristics of the
voltage waveform applied across the insulation. In addition
to the testing performed by the regulatory agencies, Analog
Devices carries out an extensive set of evaluations to determine
the lifetime of the insulation structure within the ADuM3190.
nificantly lower. This allows operation at higher working voltages
while still achieving a 50-year service life. Treat any cross-insulation
voltage waveform that does not conform to Figure 38 or Figure 39
as a bipolar ac waveform, and limit its peak voltage to the 50-year
lifetime voltage value listed in Table 8.
0V
Figure 38. Unipolar AC Waveform
RATED PEAK VOLTAGE
11335-016
INSULATION LIFETIME
0V
Figure 39. DC Waveform
ADuM3190
Data Sheet
PACKAGING AND ORDERING INFORMATION
OUTLINE DIMENSIONS
0.197 (5.00)
0.193 (4.90)
0.189 (4.80)
16
9
0.158 (4.01)
0.154 (3.91)
0.150 (3.81)
1
8
0.010 (0.25)
0.006 (0.15)
0.069 (1.75)
0.053 (1.35)
0.065 (1.65)
0.049 (1.25)
0.010 (0.25)
0.004 (0.10)
COPLANARITY
0.004 (0.10)
0.244 (6.20)
0.236 (5.99)
0.228 (5.79)
0.025 (0.64)
BSC
SEATING
PLANE
0.012 (0.30)
0.008 (0.20)
8°
0°
0.050 (1.27)
0.016 (0.41)
0.020 (0.51)
0.010 (0.25)
0.041 (1.04)
REF
09-12-2014-A
COMPLIANT TO JEDEC STANDARDS MO-137-AB
CONTROLLING DIMENSIONS ARE IN INCHES; MILLIMETER DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF INCH EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.
Figure 40. 16-Lead Shrink Small Outline Package [QSOP]
(RQ-16)
Dimensions shown in inches and (millimeters)
ORDERING GUIDE
Model1, 2
ADuM3190ARQZ
ADuM3190ARQZ-RL7
ADuM3190BRQZ
ADuM3190BRQZ-RL7
ADuM3190SRQZ
ADuM3190SRQZ-RL7
ADuM3190TRQZ
ADuM3190TRQZ-RL7
ADuM3190WSRQZ
ADuM3190WSRQZ-RL7
ADuM3190WTRQZ
ADuM3190WTRQZ-RL7
EVAL-ADuM3190EBZ
1
2
Temperature Range
−40°C to +85°C
−40°C to +85°C
−40°C to +85°C
−40°C to +85°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
Bandwidth (Typical)
200 kHz
200 kHz
400 kHz
400 kHz
200 kHz
200 kHz
400 kHz
400 kHz
200 kHz
200 kHz
400 kHz
400 kHz
Package Description
16-Lead QSOP
16-Lead QSOP
16-Lead QSOP
16-Lead QSOP
16-Lead QSOP
16-Lead QSOP
16-Lead QSOP
16-Lead QSOP
16-Lead QSOP
16-Lead QSOP
16-Lead QSOP
16-Lead QSOP
Evaluation Board
Package Option
RQ-16
RQ-16
RQ-16
RQ-16
RQ-16
RQ-16
RQ-16
RQ-16
RQ-16
RQ-16
RQ-16
RQ-16
Z = RoHS Compliant Part.
W = Qualified for Automotive Applications.
AUTOMOTIVE PRODUCTS
The ADuM3190W models are available with controlled manufacturing to support the quality and reliability requirements of automotive
applications. Note that these automotive models may have specifications that differ from the commercial models; therefore, designers
should review the Specifications section of this data sheet carefully. Only the automotive grade products shown are available for use in
automotive applications. Contact your local Analog Devices account representative for specific product ordering information and to
obtain the specific Automotive Reliability reports for these models.
©2013–2015 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D11335-0-7/15(A)
www.analog.com/ADuM3190
Rev. A | Page 18 of 18
Similar pages