Astec AEE00CC12-4 Total power: 10 watts input, voltages: 12v, no. of outputs: single and dual Datasheet

10 Watts
Total Power:
Input Voltages:
No. of Outputs:
10 Watts
12V
Single and Dual
AEE00-12Vin
Electrical Specs
Input
Input range
9 to 18 VDC
Efficiency
78% typical (3.3V)
Output
Special Features
•
•
•
•
•
•
10 W, Dual output
2:1 Input range
1.0" x 2.0" x 0.33 case
Industry standard package
Low Profile
Low Cost
Voltage tolerance
Overall regulation
Noise/ripple
Transient response
±1.0%
±1% max
1% Typ, 2% Max
300 usec typical (50% step load
change to within 3%Vo)
Temperature Regulation
±0.02 %Vo/°C
Switching frequency
330kHz
Isolation
I/O isolation
1500 VDC Input to Output
1000 VDC Input to Case
1000 VDC Output to Case
Isolation Resistance
300 Mohms
Environmental
Operating base temperature range:
-25°C to +100°C
Storage temperature: -40°C to +125°C
MTBF: 3 Million Hours (Belcore TR332)
Safety
2
UL
UL1950 Recognition
CSA
CSA22.2-950 Recognition
TUV
EN60950 Recognition
North America (USA): 1-888-41-ASTEC
Europe (UK): 44 (1384) 842-211Asia (HK): 852-2437-9662
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Ordering Information
Input
Voltage
Output
Voltage
Efficiency
Model Number
9-18 V
9-18 V
9-18 V
9-18 V
3.3V @ 2.55 A
5.0V @ 2 A
12V @ 0.84 A
15V @ 0.68 A
78%
81%
83%
84%
AEE02F12-49
AEE02A12-49
AEE00B12-49
AEE00C12-49
9-18 V
9-18 V
9-18 V
±5V @ ± 1.0 A
±12V @ ±0.42 A
±15V @ ±0.33 A
81%
83%
84%
AEE01AA12-4
AEE00BB12-4
AEE00CC12-4
NOTES:
Enable Function
"4" = positive logic enable
Trim Feature
"9" = Trim feature
Mechanical Dimensions and Pin Assignments
Notes:
1. 20 MHz bandwidth. An external 0.1 uf ceramic capacitor
is recommended to be placed from +V out to comm.
2. All specifications are typical at nominal line, full load,
and 25°C unless otherwise noted.
3. All specifications subject to change without notice.
4. Mechanical drawings are for reference only.
www.astec.com
3
Similar pages