Vishay BAT54A-V Small signal schottky diodes, single & dual Datasheet

BAT54-V, BAT54A-V, BAT54C-V, BAT54S-V
Vishay Semiconductors
Small Signal Schottky Diodes, Single and Dual
Features
• These diodes feature very low turn-on
voltage and fast switching
• These devices are protected by a PN
junction guard ring against excessive
voltage,
such
as
electrostatic
discharges
• AEC-Q101 qualified
• Compliant to RoHS directive 2002/95/EC and in
accordance to WEEE 2002/96/EC
BAT54-V
BAT54A-V
3
3
Top View
Mechanical Data
Case: SOT-23
Weight: approx. 8.8 mg
Packaging codes/options:
GS18/10K per 13" reel (8 mm tape), 10K/box
GS08/3K per 7" reel (8 mm tape), 15K/box
1
2
1
2
BAT54C-V
BAT54S-V
3
3
Top View
1
2
1
2
18034
Parts Table
Part
Ordering code
BAT54-V
Type marking
Remarks
BAT54-V-GS18 or BAT54-V-GS08
L4
Tape and reel
BAT54A-V
BAT54A-V-GS18 or BAT54A-V-GS08
L42
Tape and reel
BAT54C-V
BAT54C-V-GS18 or BAT54C-V-GS08
L43
Tape and reel
BAT54S-V
BAT54S-V-GS18 or BAT54S-V-GS08
L44
Tape and reel
Absolute Maximum Ratings
Tamb = 25 °C, unless otherwise specified
Parameter
Test condition
Repetitive peak reverse voltage
Forward continuous current
Repetitive peak forward current
Surge forward current current
tp < 1 s
Power dissipation
Symbol
Value
Unit
VRRM
30
V
IF
200 1)
mA
IFRM
300 1)
mA
IFSM
600 1)
mA
Ptot
230
mW
Symbol
Value
Unit
1)
K/W
Note
1)
Device on fiberglass substrate, see layout on next page.
Thermal Characteristics
Tamb = 25 °C, unless otherwise specified
Parameter
Test condition
Thermal resistance junction to ambient air
Junction temperature
Storage temperature range
RthJA
430
Tj
125
°C
Tstg
- 65 to + 150
°C
Note
1)
Device on fiberglass substrate, see layout on next page.
Document Number 85508
Rev. 1.7, 16-Jul-10
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
1
BAT54-V, BAT54A-V, BAT54C-V, BAT54S-V
Vishay Semiconductors
Electrical Characteristics
Tamb = 25 °C, unless otherwise specified
Parameter
Test condition
Symbol
Min.
IR = 100 µA (pulsed)
V(BR)
30
Pulse test tp < 300 µs, δ < 2 % at
VR = 25 V
IR
2
µA
IF = 0.1 mA, tp < 300 µs, δ < 2 %
VF
240
mV
IF = 1 mA, tp < 300 µs, δ < 2 %
VF
320
mV
IF = 10 mA, tp < 300 µs, δ < 2 %
VF
400
mV
IF = 30 mA, tp < 300 µs, δ < 2 %
VF
500
mV
IF = 100 mA, tp < 300 µs, δ < 2 %
VF
800
mV
VR = 1 V, f = 1 MHz
CD
10
pF
IF = 10 mA to IR = 10 mA,
iR = 1 mA, RL = 100 Ω
trr
5
ns
Reverse Breakdown voltage
Leakage current
Forward voltage
Diode capacitance
Reverse recovery time
Typ.
Max.
Unit
V
Layout for RthJA test
Thickness:
Fiberglass 1.5 mm (0.059 in.)
Copper leads 0.3 mm (0.012 in.)
7.5 (0.3)
3 (0.12)
1 (0.4)
2 (0.8)
1 (0.4)
12 (0.47)
15 (0.59)
2 (0.8)
0.8 (0.03)
5 (0.2)
1.5 (0.06)
5.1 (0.2)
17451
Typical Characteristics
Tamb = 25 °C, unless otherwise specified
14
100
C D - Typical Capacitance (pF)
I F - Forward Current (mA)
1000
T j = 125 °C
- 40 °C
10
1
25 °C
0.1
0.01
0
18867
2
10
8
6
4
2
0
0.2
1.2
0.4 0.6 0.8
1
VF - Forward Voltage (V)
0
1.4
Figure 1. Typical Forward Voltage Forward Current vs.
Various Temperatures
www.vishay.com
12
18868
4
12
16
20
24
8
VR - Reverse Voltage (V)
28
Figure 2. Diode Capacitance vs. Reverse Voltage VR
For technical questions within your region, please contact one of the following: Document Number 85508
[email protected], [email protected], [email protected]
Rev. 1.7, 16-Jul-10
BAT54-V, BAT54A-V, BAT54C-V, BAT54S-V
Vishay Semiconductors
1000
I R - Reverse Current (µA)
T j = 125 °C
100
100 °C
75 °C
10
50 °C
1
25 °C
0.1
0.01
0
5
18869
10
15
20
25
VR - Reverse Voltage (V)
30
Figure 3. Typical Variation of Reverse Current
vs. Various Temperatures
Package Dimensions in millimeters (inches): SOT-23
0.9 (0.035)
1.15 (0.045)
o8
°
0.2 (0.008)
0.098 (0.004)
0.175 (0.007)
0.550 ref. (0.022 ref.)
0.1 (0.004) max.
3.1 (0.122)
2.8 (0.110)
0.45 (0.018)
0.35 (0.014)
0.35 (0.014)
0° t
0.5 (0.020)
0.45 (0.018)
0.3 (0.012)
2.6 (0.102)
2.35 (0.093)
0.7 (0.028)
0.95 (0.037)
0.9 (0.035)
1.43 (0.056)
1 (0.039)
0.9 (0.035)
Foot print recommendation:
2 (0.079)
1 (0.039)
0.9 (0.035)
1.20 (0.047)
0.45 (0.018)
0.35 (0.014)
0.95 (0.037)
Document no.: 6.541-5014.01-4
Rev. 8 - Date: 23.Sept.2009
17418
Document Number 85508
Rev. 1.7, 16-Jul-10
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
3
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Revision: 12-Mar-12
1