Click on Series name for product info on aimtec.com Series AM30K-NZ 30 Watt | DC-DC Converter FEATURES: RoHS compliant Remote On/Off control High Efficiency up to 90% Input Under voltage protection Trim adjustment Power modules for PCB mounting Operating temperature range: -40 to +85ºC Standard package Models Single output Model Input Voltage (V) Output Voltage (V) 18 – 36 18 – 36 18 – 36 18 – 36 36 – 75 36 – 75 36 – 75 36 – 75 5 12 15 24 5 12 15 24 AM30K-2405S-NZ AM30K-2412S-NZ AM30K-2415S-NZ AM30K-2424S-NZ AM30K-4805S-NZ AM30K-4812S-NZ AM30K-4815S-NZ AM30K-4824S-NZ Output Current max (A) Maximum capacitive load (µF) Efficiency (%) 10200 3240 1100 900 10200 3240 1100 900 88 89 89 88 89 90 90 90 6 2.5 2 1.25 6 2.5 2 1.25 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal Typical 12 24 48 Filter Start up time Absolute Maximum Rating Under Voltage protection Units VDC ms 20 40 VDC 80 100 ms 3.5 to 12VDC or open circuit 0 to 1.2VDC or short circuit between pin 2 and 3 8 16 VDC 33 12 Vin 24 Vin 48 Vin Peak Input Voltage time Remote On/Off Control Maximum 9-18 18-36 36-75 (Pi) Network 25 On Off 9-18 Vin OFF 18-36 Vin OFF 36-75 Vin OFF Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance www.aimtec.com F 051e R8.J Conditions Typical 60 sec At 500Vdc 100KHz / 1V >1000 1000 Tel: +1 514 620 2722 1 of 3 Rated Units 1500 VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30K-NZ 30 Watt | DC-DC Converter Output Specifications Parameters Conditions Voltage accuracy Line voltage regulation Load voltage regulation Short Circuit protection Short Circuit restart Over current protection Temperature coefficient Ripple & Noise Transient Response Recovery Time Transient response overshoot Voltage adjustment range Typical Maximum ±1 ±0.2 ±0.5 Continuous Auto Recovery >120 0.02 100 200 LL-HL 10% to 100% Load Input Voltage Range 20MHZ Bandwidth 25% load step change Units % % of Vin % 160 % %/oC mV p-p μs ±2 ±10 ±5 % of Vout % Typical Maximum Units 95 KHz oC oC oC 95 % General Specifications Parameters Conditions Switching frequency Operating temperature Storage temperature Case temperature Cooling Humidity Case material Weight Dimensions (L X W X H) MTBF 100% load With derating above +71°C Tolerance ±0.5mm g 50.80 x 40.60 x 11.10mm Dimensions 50.80 (2.00) 4 2 5 3 2.54 (0.10) Printed Face Bottom View 10.16 (0.40) 1 6 45.72 (1.80) 5.10 10.16 (0.20) (0.40) 7.62 10.16 5.08 (0.30) (0.40) (0.20) +V Input -V Input On/Off Control +V Output -V Output Trim Black Anodized Aluminum 45 2.00 x 1.60 x 0.44 inches >1 000 000 hrs 40.60 (1.60) Single 1 2 3 4 5 6 -40 to +85 -55 to +105 Free air convection Pin Out Specifications Pin 300 2.54 (0.10) 4.10 (0.16) 11.10 (0.44) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Pitch Tolerance ±0.35 (±0.014) Ø 1.50 (0.06) www.aimtec.com F 051e R8.J Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30K-NZ 30 Watt | DC-DC Converter Trimming Derating Free Air Convection 71ºC Output Power (%) 100 80 60 Safe Operating Area 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C Recommended EMI Filtering (if required by end application) Note: should your application not require filtering, no additional circuits are required. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R8.J Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only