Mean Well ELN-60-27 60w single output class 2 switching power supply Datasheet

60W Single Output Class 2 Switching Power Supply
ELN-60
series
Features :
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Optional dimming function : 1~10VDC (D type) or PWM (P type) controlled
Fully isolated plastic case with IP64 level
Class
power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications (Note.9)
100% full load burn-in test
Low cost, high reliability
2 years warranty
LPS IP64
SPECIFICATION
MODEL
DC VOLTAGE
ELN-60-9
ELN-60-12
9V
LED OPERATION VOLTAGE Note.8 3 ~ 9V
( except for 48V )
ELN-60-15
ELN-60-24
ELN-60-27
ELN-60-48
12V
15V
24V
27V
48V
6 ~ 12V
7.5 ~ 15V
12 ~ 24V
13.5 ~ 27V
24 ~ 48V
RATED CURRENT
5A
5A
4A
2.5A
2.3A
1.3A
CURRENT RANGE
0 ~ 5A
0 ~ 5A
0 ~ 4A
0 ~ 2.5A
0 ~ 2.3A
0 ~ 1.3A
RATED POWER
45W
60W
60W
60W
62.1W
62.5W
120mVp-p
150mVp-p
150mVp-p
200mVp-p
250mVp-p
10.8 ~ 13.2V
13.5 ~ 16.5V
21.6 ~ 26.4V
24.3 ~ 29.7V
43.2 ~ 52.8V
87%
87%
88%
RIPPLE & NOISE (max.) Note.2 120mVp-p
OUTPUT
( for 48V only)
VOLTAGE ADJ. RANGE Note.7
8.7 ~ 10.5V
Can be adjusted by internal potentiometer SVR1
CURRENT ADJ. RANGE Note.7 -25% ~ 3%. Can be adjusted by internal potentiometer SVR2
VOLTAGE TOLERANCE Note.3
5.0%
LINE REGULATION
1.0%
2.0%
LOAD REGULATION
SETUP, RISE TIME
Note.6 500ms, 30ms / 230VAC
50ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
INPUT
Note.4 90 ~ 264VAC
1500ms, 30ms / 115VAC at full load
16ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
82%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
1.2A/115VAC 0.7A/230VAC
COLD START 60A/230VAC
LEAKAGE CURRENT
OVER CURRENT
PROTECTION
OVER VOLTAGE
85%
86%
0.25mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
11 ~ 13.5V
13.8 ~ 16V
17.5 ~ 21V
28 ~ 32V
31 ~ 35V
54 ~ 60V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION DIMMING CONTROL (OPTIONAL) 1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY &
EMC
-40 ~ +80 , 10 ~ 95% RH
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
ISOLATION RESISTANCE
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
EMC EMISSION
DIMENSION
PACKING
NOTE
(Refer to "Derating Curve")
SAFETY STANDARDS
EMC IMMUNITY
MTBF
OTHERS
-20 ~ +60
20 ~ 90% RH non-condensing
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
603Khrs min. MIL-HDBK-217F (25
181*61.5*35mm (L*W*H)
0.4Kg; 24pcs/11Kg/0.75CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
9. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name:ELN-60-SPEC 2012-03-20
ELN-60
60W Single Output Class 2 Switching Power Supply
Mechanical Specification
Case No.960A
series
Unit:mm
181
21.25
6.26
300 20
2-R2.5
+V(Red)
-V(Black)
61.5
300 20
SVT 18AWG 2C
T case
15
SVT 18AWG 2C
116.5
21.25
AC/L(Brown)
AC/N(Blue)
6.26
35
T case: Max. Case Temperature.
OUTPUT(with optional dimming function)
Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2
shown in the diagram.
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
UL2464 18AWG 4C
SVR1
SVR2
SVR1 Output voltage adjustment
SVR2 Output current adjustment
fosc : 60KHz
Block Diagram
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
DIM-
O.L.P.
DETECTION
CIRCUIT
PWM
CONTROL
10V PWM
or
1~10V
O.C.P.
O.V.P.
DIM+
Derating Curve
Optional
Dimming Control
Static Characteristics
100
100
90
80
80
70
50
LOAD (%)
LOAD (%)
60
40
20
-20
-15
-5
0
15
30
40 45 50
AMBIENT TEMPERATURE ( )
60 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:ELN-60-SPEC 2012-03-20
ELN-60
60W Single Output Class 2 Switching Power Supply
series
Dimming Control (Optional)
Level of output current can be adjusted through the dimming control function.
When there is no signal sending to the control wires (open circuit between the two control wires), the power supply
unit will operate as 0V (D-type) or 0% duty (P-type) of input signal and hence the output current will be zero.
(1)1~10V (D type, & : ELN-60- 12 D)
95%
DIM+
Output Current
+
Vdc
DIMVdc: 1~10V
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
45%
5%
0%
0
1
2
3
4
5
6
7
8
9
10
DC Input
(2)PWM (P type, & : ELN-60- 12 P)
V
Output Current
f: 100Hz ~ 3KHz
f
10V
t1
t2
Duty= t1 ,0 ~ 100%
t1+t2
Lo:0V
Hi:10V
f
95%
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
60%
15%
0%
0%
11%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Duty Cycle
File Name:ELN-60-SPEC 2012-03-20