Click on Series name for product info on aimtec.com Series AMES15-MAZ 15 Watt | AC-DC / DC-DC Converter FEATURES: Screw Terminals on Input & Output Operating temperature: -40 to +80°C Over load, Over Voltage, Short Circuit Protection Optional DIN Rail mounting bracket Universal input: 90-264VAC, 47-440Hz RoHS compliant Soft start Energy Star compliant CE, cULus, CB approvals 4000VAC I/O Isolation CB Models Single output Model Input Voltage (VAC/Hz) AMES15-3.3SMAZ AMES15-5SMAZ AMES15-12SMAZ AMES15-15SMAZ AMES15-24SMAZ Input voltage (VDC) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 130-370 130-370 130-370 130-370 130-370 Input Voltage (VAC/Hz) Input voltage (VDC) Max Output wattage Output Voltage (V) (W) 9.9 15 15 15 15 3.3 5 12 15 24 Output Current max (A) 3 3 1.25 1 0.63 Maximum Capacitive Load (µF) 4700 2200 1000 680 470 Efficiency (%) 115 230 VAC VAC 74 75 81 81 83 74 76 82 83 83 Models Dual output Model AMES15-5DMAZ AMES15-12DMAZ AMES15-15DMAZ 90-264/47-440 90-264/47-440 90-264/47-440 130-370 130-370 130-370 Max Output wattage Output Voltage (V) (W) 15 15 15 ±5 ±12 ±15 Output Current max (A) ±1.5 ±0.63 ±0.5 Maximum Capacitive Load (µF) ±1000 ±470 ±330 Efficiency (%) 115 230 VAC VAC 78 81 82 79 82 83 Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External Fuse Input Dissipation Under Voltage Protection Conditions Typical 115VAC 230VAC 115 VAC 230 VAC 115 VAC 264 VAC (recommend)slow blow type (110/230Vac) Maximum Units 350 180 10 20 0.1 0.2 mA mA A A mA mA A W VAC Maximum Units 2 0.2 85 Output Specifications Parameters Voltage accuracy Line regulation Load regulation (single output) Cross regulation (dual output) Transient Recovery Time Transient Recovery Deviation Ripple & Noise* Hold-up time Conditions Typical LL-HL 0-100% 25% load - 1st out, 100% load – 2nd out 25% load step 3.3/5V models 12/15V models 24V models min ±2 ±1 ±1 ±5 300 ±2 75 100 150 20 % % % % µs % of Vout mVp-p ms * Ripple and Noise are measured at 20MHz bandwidth by using 0.1μF (M/C) and 47μF (E/C) parallel capacitor. www.aimtec.com F 052e R7.R Tel: +1 514 620 2722 1 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMES15-MAZ 15 Watt | AC-DC / DC-DC Converter Isolation Specifications Parameters Conditions Tested I/O voltage Isolation resistance Typical 60 sec Rated Units 4000 VAC MΩ Maximum Units >1000 General Specifications Parameters Conditions Switching frequency Protection class Start up time Over load protection Over voltage protection Short circuit protection Case material Operating temperature Storage temperature Max Case temperature Temperature coefficient Cooling Humidity Weight Dimensions (L x W x H) Foldback With derating over 55 oC (10CFM) MTBF Typical 132 Class II 350 >130 Zener diode clamp Auto recovery Metal -40 to +80 -50 to +100 KHz mS % oC oC 100 oC ±0.02 Free air convection % / oC 95 100 3.62 x 2.56 x 0.94 inches 92.0 x 65.0 x 24.0 mm > 400,000hrs (MIL-HDBK -217F, t=+25oC) > 100,000hrs (MIL-HDBK -217F, t=at highest operating temperature) % RH g NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Shock Vibrations Conditions Wave form: Half sine wave Acceleration amplitude: 5gn Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety & EMC Specifications Parameters Agency approvals cULus, CE, CB IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-M90 Information technology Equipment EN 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55011, class B Harmonic Current Emissions IEC/EN 61000-3-2, Class A Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 3 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 2 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) 2 of 5 North America only Medical Electrical Equipment Standards www.aimtec.com F 052e R7.R Series AMES15-MAZ 15 Watt | AC-DC / DC-DC Converter Derating A A B 100 Free Air Convection 40 º C 80 B 60 40 10 CFM 55 º C Safe Operating Area 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C Pin Out Specifications Pin Single Dual 1 2 3 4 5 AC Input (N) AC Input (L) -V Output No Connection +V Output AC Input (N) AC Input (L) -V Output Common +V Output www.aimtec.com F 052e R7.R Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMES15-MAZ 15 Watt | AC-DC / DC-DC Converter 24 (0.94) Dimensions PCB Mounting Screw PCB Mounting Screw Side View PCB Mylar Film Bracket Mountin g Screw PCB Mylar Film 2.6 mm Max Customer Chassis www.aimtec.com F 052e R7.R Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMES15-MAZ 15 Watt | AC-DC / DC-DC Converter Optional DIN Rail Bracket NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R7.R Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only