Emerson Network Power EXB100-48S3V3-RJ 100 w dc-dc isolated converter Datasheet

EXB100 Series
Single output
DC-DC CONVERTERS
•
•
•
•
•
•
•
•
100 W DC-DC Isolated Converters
1
NEW Product
Ultra wide trim range, 60% to 110% (1.08 Vdc to 5.5 Vdc)
High efficiency, 91.5% @ 5 Vdc, 90.5% @ 3.3 Vdc
Basic insulation (input to output)
Industry standard half-brick pin-out
No minimum load
Overvoltage and overtemperature protection
Remote ON/OFF
Available RoHS compliant
The EXB100 series of 100 W single output isolated dc-dc converters are specially
designed to meet the power needs of low voltage silicon. Housed in an open-frame
package with standard footprint, these latest generation converters offer efficiencies as
high as 91.5% (typical on 5 V at 20 A). The series comprises two 48 V input models
with 5 V and 3.3 V outputs. The 3.3 V model features a wide input range, trimmable
output voltage and 30 A output (the 5 V model is limited to 20 A). Remote sense and
remote ON/OFF facilities are included as standard, and the converters are
comprehensively protected against overcurrent, overvoltage and overtemperature
conditions.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage adjustability
60% to 110%
Output setpoint accuracy
1.5%
Line regulation
Low line to high line
±0.2% max.
Load regulation
Full load to min. load
±0.4% max.
Total error band
Overshoot
None
None
GENERAL SPECIFICATIONS
0%
At turn-on and turn-off
Undershoot
Ripple and noise
5 Hz to 20 MHz
(See Note 1)
Transient response
(See Note 2)
Deviation
100 mV pk-pk
50 mV rms
150 mV
300 µs recovery to
within total error band
36-75 Vdc
Input voltage range
No load
Remote OFF
150 mA
20 mA
Efficiency
See table
Basic insulation
Input/output
Switching frequency
(Fixed)
5V
3.3 V
Input current (max.)
(See Note 3)
3.15 A max. @ Io max.
and Vin = 36-75 Vdc
Input reflected ripple
(See Note 4)
60 mA (pk-pk)
Remote ON/OFF
Logic compatibility
ON
OFF
(See Note 5)
Open collector ref to -input
>2 Vdc
<1.2 Vdc
Undervoltage lockout
Power up
Power down
Start-up time
(See Note 6)
Power up
Remote ON/OFF
36 V
30 V
1500 Vdc
300 kHz typ.
220 kHz typ.
TÜV Product Service
UL/cUL60950
UL94V-0
Material flammability
Weight
MTBF
Representative model:
Level A
Level B
Level A
EN61000-4-2 8 kV, 15 kV
EN61000-4-2 6 kV, 8 kV
EN61000-4-3 10 V/m
EN61000-4-6 10 V
EN61000-4-6 10 V
(See Note 5)
ETS 300 132-2, ETR 283
Approvals and
standards (See Note 8)
INPUT SPECIFICATIONS
Input current
Radiated emissions
EN55022 (See Note 7)
EN55022 (See Note 7)
EN55022
(See Longform Datasheet)
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (DC power)
Conducted (signal)
Input transients
3.0%
Minimum load
Conducted emissions
45 g (1.59 oz)
1,034,000 hours
MIL-HDBK-217F
100% load, ground benign
591,000 hours
BELLCORE 332
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Altitude derating
(above sea level)
Operating ambient
temperature
Non-operating
3,000 m
10,000 m
-40 °C to +90 °C
-40 °C to +125 °C
20%
50%
40 ms
35 ms
File Name: exb100s.pdf Rev: 18 Apr 2006
EXB100 Series
Single output
DC-DC CONVERTERS
100 W DC-DC Isolated Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
POWER
(MAX.)
INPUT
VOLTAGE
OVP
100 W
36-75 Vdc
100 W
36-75 Vdc
NEW Product
OUTPUT
VOLTAGE
OUTPUT
CURRENT
(MIN.)
OUTPUT
CURRENT
(MAX.)
EFFICIENCY
(TYP.)
LINE
LOAD
MODEL
NUMBER (10)
6.0 Vdc
5V
0A
20 A
91.5%
±0.2%
±0.4%
EXB100-48S05J (9)
3.9 Vdc
3.3 V
0A
30 A
90.5%
±0.2%
±0.4%
EXB100-48S3V3-RJ
Notes
REGULATION
PROTECTION
Measured as per recommended set-up. See Application Note 129 for details.
di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
3 Recommended input fusing is a 5 A HRC 200 V rated fuse.
4 Measured with external filter. See Application Note 129 for details.
5 Signal line assumed <3 m in length.
6 Start-up into resistive load.
7 The EXB100 meets levels A and B conducted emissions with external
components. See Application Note 129 for details.
8 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
9 Negative remote ON/OFF option also available. Add suffix ‘-R’ to part
number, for example EXB100-48S05-RJ.
10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
1
2
Short circuit
Continuous
Overvoltage
Non-latching clamp
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2 input voltage
and current requirements
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
Remote ON/OFF
4
+Vin
5
+Vout
6
+Sense
7
Trim
8
-Sense
9
-Vout
Vin-
VoSenseTrim
Sense+
Remote
ON/OFF
0.400
(10.16)
0.700
0.500
(17.78)
(12.70)
1.000
(25.40)
1.400
(35.56)
3
0.161
(4.09)
No Pin
0.138
(3.50)
2
Ø0.040 ±0.002
(Ø1.02 ±0.05)
6 Places
Ø0.080 ±0.002
(Ø2.03 ±0.05)
Minimum clearance from
2 Places
seating plane to
underside components
All dimensions in inches (mm)
General tolerance ±0.01in (±0.25mm)
except where specified otherwise
2.280±0.02
(57.91±0.5)
1.000
(25.40)
-Vin
0.012
(0.3)
Min
1
0.500
(12.70)
FUNCTION
1.400
(35.56)
PIN NUMBER
seating plane
2.400±0.02
(60.96±0.5)
PIN CONNECTIONS
0.394
(10.00)
Max
Max open-frame
converter height
Vo+
Vin+
International Safety Standard Approvals
1.900
(48.26)
Bottom View
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E174104
TÜV Product Service. Certificate No. B 02 02 38572 031
Datasheet © Artesyn Technologies® 2006
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: 4 Application Note 4 Longform Datasheet
www.artesyn.com
File Name: exb100s.pdf Rev: 18 Apr 2006