AD1048FS Series Very Low Cost, 36 - 48W DIN Rail Mount Single Output AC/DC Power Supplies New Industrial Supplies!! Key Features: Electrical Specifications • 36W - 48W Output Power • DIN Rail Mountable • Universal AC Input • UL 508 Compliant • EN60950 Compliant • 12, 15, 24 & 48 VDC Outputs • Cond./Rad. EMI Class B • >170 kH MTBF • LOW COST! Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Frequency Leakage Current Max. 240 370 63 22 44 1.8 Units VAC VDC Hz A A mA Conditions Min. Typ. Max. ±0.5 ±10.0 Vin = Min to Max ±1.0 Iout = 20% to 100% ±1.0 110 VAC, Full Load 10 220 VAC, Full Load 20 See Model Selection Guide Power Limit 130 160 2 50% Load Change 5 ±0.04 ±0.05 Continuous With Autorecovery Units % % % % mSec % mS % %/ºC General Parameter Isolation Voltage T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Typ. Output Ripple & Noise (20 MHz) (Note 2) Output Power Protection Transient Recovery Time (Note 3) Transient Response Deviation Temperature Coefficient Output Short Circuit 292 Page Street Suite D Stoughton, MA 02072 USA Min. 100 127 47 110 VAC 220 VAC 264 VAC Inrush Current, Cold Start Hold Time MicroPower Direct Universal Input Voltage Range Parameter Output Voltage Accuracy Output Voltage Adjustment Range Line Regulation Load Regulation (Note 1) RoHS Compliant Conditions Isolation Resistance (Note 4) Switching Frequency Conditions Input - Output Input - FG (Frame Ground) Output - FG (Frame Ground) 500 VDC Fixed Min. 3,000 2,000 500 100 Typ. Max. Units VAC 66 MΩ kHz Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Vibration Conditions Min. Typ. Max. Units -20 +25 +50 ºC -20 +85 ºC Free Air Convection RH, Non-condensing 95 % 10 Hz ~ 2 kHz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour Ambient Physical Case Size Case Material Connection 3.54 x 2.54 x 1.77 Inches (90.0 x 64.5 x 44.0 mm) Plastic Screw Terminal Reliability Specifications Parameter MTBF Safety Standards EMI Compliance EMS Immunity Compliance Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. Typ. Max. Units 170 kHours UL 1950, EN 60950, IEC 60950 Compliance to EN55011, EN55022 (CISPR22) Class B EN6100-4-2,3,4,5,6,8,11 Level 3 Model Selection Guide Model Number Rated Power (W) AD1036-12FS AD1045-15FS AD1048-24FS AD1048-48FS 36 45 48 48 Input Voltage (VAC) Output Current (A) Universal Range 115 VAC 230 VAC 100 - 240 1.0 0.5 100 - 240 1.0 0.5 100 - 240 1.0 0.5 100 - 240 1.0 0.5 Notes: 1. Load regulation is specified for a load change of 20% to 100%. 2. Ripple & noise is measured using equipment with 20 Mhz of bandwidth with the unit under test operating at rated load and a 110 VAC input. Connection to the unit is made with a 0.1 μF / 630V metalized capacitor & a 47 μF electrolytic capacitor connected in parallel. 3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 4. Isolation resistance is given for Input/Output and Input/FG. For Output/FG., it is 50 MΩ 5. Overload protection is power limiting. The unit recovers automatically when the fault is removed. 6. Over voltage protection is a shut down type. The unit recovers automatically when the fault is removed. 7. To mount the unit to the DIN rail, tilt the unit rearwards from the top, fitting the mount over the top of the rail. Press back on the bottom front of the unit until it locks in place on the rail. To remove the unit from the rail, pull the removal clip at the bottom rear of the unit downward with a screw driver. With the clip down, lift up on the unit from the bottom front until it clears the rail. Before installation or removal all wiring should be disconnected and the main power to the system shut off. 8. When wiring the supply, all lines should be as thick and short as possible. AWG 14 wire is recommended for the AD1048FS series. 9. The units should be mounted so they are vertically orientated. Air flow (if it is provided) would optimally flow from the bottom to the top of the unit. 10. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Voltage (VDC) Current (A) Max) 12 15 24 48 3.0 3.0 2.0 1.0 Current (A) Range Overvoltage Protection (VDC) 0 ~ 3.0 0 ~ 3.0 0 ~ 2.0 0 ~ 1.0 20.0 20.0 40.0 60.0 Efficiency (%, Typ) Fuse Rating Slow-Blow (A) 80 81 83 83 2.0 2.0 2.0 2.0 Derating Curve Mechanical Dimensions Terminal Connections Pin Function 1 DC Output (+V) 2 DC Output (-V) 3 Frame Ground (FG) 4 AC/Neutral 5 AC/Live Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]