DC-DC Converter SIP-Package DAV-3 SERIES, 3WATT, REGULATED WITH 2:1 INPUT RANGE FEATURES: 3 years warranty 1500Vdc isolation voltage Wide (2:1) input voltage range Regulated single and dual output models Operating temperature range -40°C to +85°C Continuous short circuit protection Model Input voltage (Vdc) Output voltage (Vdc) Output current (mA) Min. Max. Efficiency Typ. DAV3-0511 5 30 600 80% DAV3-0512 9 25 333 80% DAV3-0513 12 25 250 80% DAV3-0514 DAV3-0515 DAV3-0521 DAV3-0522 DAV3-0523 DAV3-0524 DAV3-1211 DAV3-1212 DAV3-1213 DAV3-1214 DAV3-1215 DAV3-1221 15 20 200 80% 24 12.5 125 80% ±5 25 300 80% ±9 16.7 167 80% ±12 12.5 125 80% ±15 10 100 80% 5 30 600 80% 9 25 333 80% 12 25 250 80% 15 20 200 80% 24 12.5 125 80% ±5 25 300 80% DAV3-1222 ±9 16.7 167 80% DAV3-1223 ±12 12.5 125 80% DAV3-1224 ±15 10 100 80% DAV3-2411 5 30 600 80% DAV3-2412 9 25 333 80% DAV3-2413 12 25 250 80% DAV3-2414 15 20 200 80% 24 12.5 125 80% DAV3-2421 ±5 25 300 80% DAV3-2422 ±9 16.7 167 80% DAV3-2423 ±12 12.5 125 80% DAV3-2424 ±15 10 100 80% DAV3-2415 5(4.5~9) 12(9~18) 24(18~36) Notes: other input and output models may available on request. www.pairuigroup.com Page: 1/4 Date: 12/13/2013 DC-DC Converter SIP-Package DAV-3 SERIES, 3WATT, REGULATED WITH 2:1 INPUT RANGE ELECTRICAL Line regulation --- ±0.2% Load regulation 10% ~ 100% full load ±0.5% Ripple and noise --- 100mVp-p max. Isolation voltage --- 1500Vdc Short circuit protection --- Continuous short circuit protection Operating temperature range --- -40°C to +85°C 1x106Hrs MTBF Notes: All the data in this article are under test with “TA+25°C, humidity<75%, rated input and rated load” mode. MECHANICAL Single output CONNECTION PIN # SINGLE DUAL 1 GND GND 2 +Vin +Vin 3 CTRL CTRL 5 NC NC 6 +Vo +Vo 7 -Vo COM 8 CS -Vo Note: Dual output * Unit is mm(inch). www.pairuigroup.com Page: 2/4 Date: 12/13/2013 DC-DC Converter SIP-Package DAV-3 SERIES, 3WATT, REGULATED WITH 2:1 INPUT RANGE TEMPERATURE PROFILE CAPACITIVE LOADS SELECTION Single Output Cin (Vdc) (μF) 5 4.7-100 5 560 ±5 270 12 4.7-100 9 470 ±9 220 24 4.7-100 12 470 ±12 220 - - 15/24 330 ±15/±24 150/100 www.pairuigroup.com Voltage Cout Dual Output Vin (μF) (Vdc) Page: 3/4 Voltage (Vdc) Cout (μF) Date: 12/13/2013 DC-DC Converter SIP-Package DAV-3 SERIES, 3WATT, REGULATED WITH 2:1 INPUT RANGE NOTES RECOMMENDED TEST AND APPLICATION CIRCUIT In order to ensure the efficiency and dependability of the module, the minimum specified load must be less than 10% of rated load. If the output power is low, we recommend to add an external 10% loading resistor in parallel. FUSE: depends on the actual input current; TVS: depends on the actual input voltage; Recommended capacitor: C1, C2, C5, C8, about 0.1uF; for C6,C7,C9, please check the capacitive load; C3,C4: 2KV/1nF. www.pairuigroup.com Page: 4/4 Date: 12/13/2013