EPCOS B59502A0120A020 Motor starting Datasheet

Motor Starting
B59***
Metallized Disks
A 19*, A 314, A 5**
Applications
■ Time delay in turning off the auxiliary winding of single-phase AC motors
(e.g. refrigerator compressors)
■ Type A 314 suitable for airconditioning systems applications
Features
■
■
■
■
■
■
Metallization: CrNi (sputtered) + Ag (screen-printed), except A 314 (screen-printed Ag)
Excellent long-term reliability
Suitable for clamp contacting
UL approval to UL 1434 (file number E69802), except A 502 and A 196
VDE approval (license number 87406 E), except A 524 and A 314
CSA approval for A 506 (certificate No. 1109600)
Options
■ Other dimensions and ratings on request
Delivery mode
■ Bulk
Dimensional drawing
A 19*, A 5**
A 314
Cr/Ni
Ag
r
0,9±0,6
b
b
s
Kontaktierung
Termination
Termination
TPT0657-3
s
TPT0449-Z
Dimensions (mm)
V N = 230 Vrms
Type
b
A 502
19,5 + 0,5
A 501
19,5 + 0,5
A 550
16,0 ± 0,5
A 524
19,5 ± 0,5
A 549
16,0 ± 0,5
A 544
17,5 ± 0,5
A 192
19,5 ± 0,5
s
2,5 ± 0,2
2,5 ± 0,2
2,5 ± 0,2
2,5 ± 0,2
2,5 ± 0,2
2,5 ± 0,2
2,5 ± 0,2
V N = 230 Vrms
Type
b
A 196
19,5 ± 0,5
A 197
19,5 ± 0,5
A 314
20,0 + 0,2/– 0,8
V N = 120 Vrms
Type
b
A 508
17,5 ± 0,5
A 506
17,5 ± 0,5
154 10/02
s
3,2 ± 0,2
3,2 ± 0,2
5,0 ± 0,25
s
2,5 ± 0,2
2,5 ± 0,2
Motor Starting
B59***
Metallized Disks
A 19*, A 314, A 5**
General technical data
Switching cycles
Operating temperature range (V = 0)
(V = Vmax)
> 100000
+ 5/+ 80
+ 5/+ 80
N
Top
Top
°C
°C
Electrical specifications and ordering codes
Type
Imax
A
V N = 230 Vrms
A 502
4
A 501
6
A 550
6
A 524
7
A 549
7
A 544
8
A 192
8
A 196
8
A 197
9
A 314
9
V N = 120 Vrms
A 508
10
A 506
12
Ordering code
V
R N ± ∆R N
Ir2)
(VPTC ≤ 2,5 V)
Ω
mA
0,55
0,45
0,30
0,55
0,35
0,35
0,35
0,50
0,30
0,35
> 750
> 700
> 700
> 600
> 650
> 650
> 650
> 700
> 700
> 800
47 ± 30 %
33 ± 20 %
33 ± 20 %
22 ± 20 %
22 ± 20 %
20 ± 20 %
25 + 15/– 20 %
15 ± 30 %
33 ± 30 %
38 ± 30 %
8
8
7
10
8
12
10
10
8
10
B59502A0120A020
B59501A0135A020
B59550A0135A020
B59524A0135A020
B59549A0135A020
B59544A0120A020
B59192A0120A020
B59196A0120A020
B59197A0120B020
B59314A0120B0103)
0,55
0,45
> 360
> 360
4,7 ± 20 %
4,7 ± 20 %
17
16
B59508A0135A020
B59506A0120A020
V max
TRef
Tsurf
tS1)
VBD
V
°C
°C
s
400
355
355
300
300
320
325
350
350
400
120
135
135
135
135
120
120
120
120
120
180
190
190
190
190
180
180
180
180
190
180
180
135
120
190
180
1) Measured at V = Vmax and I = 0,8 · Imax
2) Measured with PTC thermistor mounted in standard EPCOS motor start housing
3) Type A 314 suitable for airconditioning systems applications
155 10/02
Motor Starting
B59***
Metallized Disks
A 19*, A 314, A 5**
Reliability data
Test 1)
Standard
Test conditions
| ∆R25 /R25 |
Switching test
at room temperature
IEC 60738-1
V max; R S
Room temperature
Number of cycles: 10000
< 25%
Life test at V max /Top
IEC 60738-1
Storage at V max /Top for
t : 1000 h
< 25%
Damp heat
IEC 60068-2-3
Storage at 40 °C
Relative humidity: 93%
Duration: 56 days
< 20%
Rapid change
of temperature in air
IEC 60068-2-14,
Test N a
– 25 °C, 125 °C
Number of cycles: 5
t : 30 min
< 20%
Vibration
IEC 60068-2-6,
Test FC
f = 10–55–10 Hz
h = 0,75 mm (respectively 10 g)
t: 3 · 2 h
< 20%
Bump
IEC 60068-2-27
Pulse shape: half-sine
a : = 40 g
Pulse duration: 6 ms; 6 · 4000 pulses
< 20%
Climatic sequence
IEC 60068-2-30
Dry heat: T = 125 °C, t : 16 h
Damp heat first cycle
Cold: T = – 25 °C, t : 2 h
Damp heat 5 cycles
< 25%
1) All tests with PTC disk mounted in EPCOS housing
156 10/02
Herausgegeben von EPCOS AG
Unternehmenskommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
++49 89 636 09, FAX (0 89) 636-2 26 89
(
 EPCOS AG 2002. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet.
Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG
oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen.
Published by EPCOS AG
Corporate Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
++49 89 636 09, FAX (0 89) 636-2 26 89
(
 EPCOS AG 2002. Reproduction, publication and dissemination of this brochure and the information contained therein without
EPCOS’ prior express consent is prohibited.
Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics
Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on the type in question please
also contact one of our Sales Offices.
Similar pages