CHD250 Series
AC-DC Power Supplies
250 Watts
• 250 W Convection-cooled
• Industry Standard 3”x 5”Package
• 80 VAC to 300 VAC Input
• 5V Standby (optional)
• <0.5W Standby Power
• IT & Medical (BF) Safety Approvals
• Power Fail & Inhibit Signals
• 3 Year Warranty
Dimensions:
The universal AC input CHD250 provides 250W of convection cooled output power in a 3” x 5”
industry standard package, over the temperature range -20°C to +50°C with derating to +70°C.
Approved for IT and Medical and with a feature set including a 5V standby output, <0.5W input
power when in standby mode, power fail and inhibit signals the CHD250 is ideal for a wide range of
applications where fan cooling is not desirable.
CHD250:
5.00 x 3.00 x 1.43” (115 x 76 x 36 mm)
CHD250-C:
5.50 x 3.48 x 1.75” (139.7 x 88.5 x 44.4 mm)
Models & Ratings
Output Voltage 1
Output Current V1
Standby Supply V2
(optional)
Output Power
Model Number
12 V
20.8 A
5.0 V / 0.5 A
250 W
CHD250PS12
15 V
16.7 A
5.0 V / 0.5 A
250 W
CHD250PS15
24 V
10.4 A
5.0 V / 0.5 A
250 W
CHD250PS24
28 V
8.9 A
5.0 V / 0.5 A
250 W
CHD250PS28
48 V
5.2 A
5.0 V / 0.5 A
250 W
CHD250PS48
Notes
1. Add suffix ‘-C’ for cover version e.g. CHD250PS24-C (derating will be applicable, see derating curve fig. 8).
2. Add suffix -A for 5 V standby option or -AC for standby and cover options combined, (derating will be applicable, see derating curve fig. 8).
Mechanical Details
5.00 ±0.02 (127.0 ±0.51)
ø0.14 (3.5)
thru in 4 positions
L3
Input Connector
CON1
2.55
(64.7)
A
Output
Voltage
Control
C64
3.00 ±0.02
(76.2 ±0.51)
1
-VE
C53
2
+VE
T1
E
0.22 0.92 0.22
(5.71) (23.4) (5.71)
Output
Terminals
M4 Screws in
2 positions.
4.55 (115.5)
Torque to
8lbs-in
(90 cNm) max.
1.43 ±0.04
(36.3 ±1.0)
Pin 2
Pin 1
Pin 10
Pin 9
Detail A
Signals Connector CON4
10 Way JST B10B-PHDSS
Scale 3:1
1
www.xppower.com
5
(1,2)
CHD250 Series
AC-DC Power Supplies
Input
Characteristic
Input Voltage - Operating
Minimum
Typical
Maximum
Units
Notes & Conditions
80
115/230
264
VAC
Derate output power < 90 VAC. See fig. 1
300
VAC
5 seconds max
47
50/60
63
Hz
Input Voltage - Fault Condition
Input Frequency
Power Factor
>0.93
Input Current - Full Load
2.4/1.3
EN61000-3-2 class C for loads ≥10%
0.5
No Load Input Power
Inrush Current
Earth Leakage Current
Input Protection
Agency approval, 47-63 Hz
EN61000-3-2 class A compliant
A
115/230 VAC
W
All models, when inhibit activated
3.2
W
CHD250PS12 - 115V AC
3.1
W
CHD250PS12 - 230V AC
3.8
W
CHD250PS24 - 115V AC
3.1
W
CHD250PS24 - 230V AC
3.5
W
CHD250PS48 - 115V AC
2.8
W
CHD250PS48 - 230V AC
20
40
A
264 VAC cold start
85/170
250
µA
Typ. 115/230 VAC 50 Hz, Max 264 VAC 60 Hz
5 A/250 V internal fuse in both AC lines
Input Voltage Derating
Figure 1
300
Output Power (W)
250
200
150
100
50
85
80
90
Input Voltage (VAC)
264
275
Output
Characteristic
Minimum
Output Voltage
12
Typical
Initial Set Accuracy
Output Voltage Adjustment
Minimum Load
Maximum
Units
Notes & Conditions
48
VDC
See Models and Ratings table
±1
%
+5/-4
%
0
50% load, 115/230 VAC
A
Start Up Delay
1.3
Hold Up Time
15
2.0
s
115/230 VAC full load from input AC turn on
ms
90 VAC, full load
After 20 min warm up
Drift
±0.2
%
Line Regulation
±0.5
%
90-264 VAC at 50% load
Load Regulation
±0.5
%
On V1, from 0-100% load
<4
%
Recovery within 1% in less than 500 µs
for a 50-75%-50% load change
Transient Response
Ripple & Noise
1
% pk-pk
Overvoltage Protection
115
140
%
Overload Protection
110
150
%
Short Circuit Protection
Vnom DC. Output 1, recycle input to reset
Trip & Restart characteristic V1
Shutdown and auto recovery
Temperature Coefficient
0.05
%/˚C
100
µA
Overtemperature Protection
Patient Leakage Current
20 MHz bandwidth
Not fitted
83
www.xppower.com
264 VAC/60 Hz
2
CHD250 Series
AC-DC Power Supplies
General
Characteristic
Minimum
Typical
Isolation: Input to Output
Input to Ground
Output to Ground
Maximum
Notes & Conditions
Units
93-94
Efficiency
%
230 VAC full load
VAC
2 x MOPP
1500
VAC
1 X MOPP
1500
VAC
1 X MOPP
4000
Switching Frequency
45-280
kHz
PFC
31
kHz
Boost
63
kHz
Main converter
56-91
kHz
Standby (optional)
Power Density
11.7
Mean Time Between Failure
W/in3
213
kHrs
MIL-HDBK-217F, Notice 2 +25 °C GB
0.94 (425)
CHD250PSxx
0.97 (441)
Weight
CHD250PSxx-A
lb (g)
1.36 (619)
CHD250PSxx-C
1.40 (636)
CHD250PSxx-AC
Efficiency Vs Load
100.00%
Figure 2
90.00%
12 V Models
Efficiency (%)
80.00%
70.00%
60.00%
PS12 115V
50.00%
PS12 230V
40.00%
30.00%
20.00%
10.00%
0
20%
30%
40%
50%
60%
70%
80%
90%
100%
load %
Figure 3
24 V Models
100.00%
90.00%
Efficiency (%)
80.00%
70.00%
60.00%
PS24 115V
50.00%
PS24 230V
40.00%
30.00%
20.00%
10.00%
0
20%
30%
40%
50%
60%
70%
80%
90%
100%
load %
Figure 4
48 V Models
100.00%
90.00%
Efficiency (%)
80.00%
70.00%
60.00%
PS48 115V
50.00%
PS48 230V
40.00%
30.00%
20.00%
10.00%
0
20%
30%
40%
50%
60%
70%
80%
load %
3
www.xppower.com
90%
100%
CHD250 Series
AC-DC Power Supplies
Signals & Controls
Characteristic
Notes & Conditions
Power Fail (AC-OK)
Uncommitted isolated optocoupler transistor, normally off when AC is good (see fig.5)
Provides 5 ms warning of loss of output from AC failure off when AC is healthy.
Inhibit
Uncommitted isolated optocoupler diode, powered diode inhibits the supply (see fig.6 & 7)
Standby Supply (optional)
5V/0.5A Isolated supply present when AC applied.
Remote Sense
Compensates for 0.25V per lead, 0.5V total drop.
Power Fail
Inhibit (High)
Inhibit (Low)
Figure 5
Figure 6
Figure 7
5V
5V
POWER SUPPLY
POWER SUPPLY
POWER SUPPLY
8V Max 3 mA
Pin 2 CON 4
Power Fail
Collector
Power Fail
Emitter
Pin 1 CON 4
5 mA
8 V Max
1K
Inhibit Hi
Pin 4 CON 4
Transistor On: Input & Output Not OK
Transistor Off: Input & Output OK
8 V Max
Inhibit Hi
Pin 4
CON 4
Inhibit Lo
Pin 3 CON 4
VI RTN
Pin 7 CON 4
Signal Connector
5 mA
Inhibit Lo
Pin 3 CON 4
VI RTN
Pin 7 CON 4
Signal Connector
Signal Connector
Environmental
Characteristic
Minimum
Typical
Maximum
Units
Operating Temperature
-20
+70
°C
Storage Temperature
-40
+85
°C
95
%RH
Notes & Conditions
See derating curve, fig.8. and Thermal
Considerations on page 8.
Cooling
Convection cooled
Humidity
5000
Operating Altitude
Non-condensing
Information Technology
m
4000
Medical
Shock
±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (±0.5msec), half sine. Conforms to EN60068-2-27 & EN60068-2-47
Vibration
Single axis 10 - 500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
Temperature Derating Curve
Figure 8
Standard & Covered (-C) versions
5 V Standby (-A & -AC) versions
300
Output Power (W)
Output Power (W)
Open Frame Convection
250
217
Covered Convection
200
125
108.5
Open Frame Convection
220
Covered Convection
165
126.5
110
82.5
0
0
-20
50
70
-20
Ambient Temperature (°C)
50
70
Ambient Temperature (°C)
www.xppower.com
4
CHD250 Series
AC-DC Power Supplies
EMC: Emissions
Phenomenon
Test Level
Standard
Conducted
EN55022/11
Radiated
EN55022/11
Harmonic Current
EN61000-3-2
Notes & Conditions
Class B
Class A
Class B
With 2 turn Wurth 742-700-56 core or similar
on AC cable
Class A
All models
Class C
>225 W
Test Level
Criteria
Notes & Conditions
High severity level
as below
EMC: Immunity
Phenomenon
Low Voltage PSU EMC
Standard
EN61204-3
Radiated
EN61000-4-3
3
A
EFT
EN61000-4-4
3
A
Surges
EN61000-4-5
Installation class 3
A
Conducted
EN61000-4-6
EN55024 (100 VAC)
EN55024 (240 VAC)
Dips and Interruptions
EN60601-1-2 (100 VAC)
EN60601-1-2 (240 VAC)
3
Int >95% (0 VAC), 8.3ms
Dip 30% (70 VAC), 416ms
A
A
B
Int >95% (0 VAC), 4160ms
B
Int >95% (0 VAC), 10.0ms
A
Dip 30% (168 VAC), 500ms
B
Int >95% (0 VAC), 5000ms
B
Int >95% (0 VAC), 10.0ms
A
Dip 60% (40 VAC), 100ms
A
Dip 30% (70 VAC), 500ms
A
Int >95% (0 VAC), 5000ms
B
Int >95% (0 VAC), 10.0ms
A
Dip 60% (96 VAC), 100ms
A
Dip 30% (168 VAC), 500ms
A
Int >95% (0 VAC), 5000ms
B
Derate output power to 120 W
Safety Approvals
Safety Agency
CB Report
UL
TUV
5
Safety Standard
Notes & Conditions
IEC60950-1 Ed 2
Information Technology
IEC60601-1 Ed 3 Including Risk Management
Medical
UL60950-1 (2007), CSA 22.2 No.60950-1-1:08
Information Technology
ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:08
Medical
EN60950-1
Information Technology
EN60601-1
Medical
CE
LVD & RoHS
Equipment Protection Class
Class I & BF
See safety agency conditions of acceptibility for details
Means of Protection
Category
Primary to Secondary
2 x MOPP (Means of Patient Protection)
Primary to Earth
1 x MOPP (Means of Patient Protection)
Secondary to Earth
1 x MOPP (Means of Patient Protection)
IEC60601-1 Ed 3
www.xppower.com
CHD250 Series
AC-DC Power Supplies
Mechanical Details
CHD250
5.00 ±0.02 (127.0 ±0.51)
ø0.14 (3.5)
thru in 4 positions
L3
Input Connector
CON1
2.55
(64.7)
A
Output
Voltage
Control
C64
3.00 ±0.02
(76.2 ±0.51)
1
-VE
C53
2
+VE
T1
E
0.22 0.92 0.22
(5.71) (23.4) (5.71)
Output
Terminals
M4 Screws in
2 positions.
4.55 (115.5)
Torque to
8lbs-in
(90 cNm) max.
1.43 ±0.04
(36.3 ±1.0)
Pin 2
Pin 1
Pin 10
Pin 9
Detail A
Signals Connector CON4
10 Way JST B10B-PHDSS
Scale 3:1
CHD250 Standby Option (-A)
ø0.14 (3.5)
thru in 4 positions
5.00 ±0.02 (127.0 ±0.51)
0.30 (7.5)
A
L3
C64
2.55
(64.7)
0.22
(5.71)
Output
Voltage
Control
C53 under
standby board
B
Standby
Board
(Option -A)
T1
0.92
(23.4) 0.22
(5.71)
A
3.00 ±0.02
(76.2 ±0.51)
1.49
37.8)
Output
Terminals
M4 Screws in
2 positions.
Torque to
8lbs-in
Pin 3 (90 cNm) max.
Pin 4
Pin 2
1.43 ±0.04
(36.3 ±1.0)
Mates with Molex housing
09-50-1031 and Molex
series 5194 crimp terminals.
Output Connector CON 3
1
+VE
2
-VE
Signals Connector CON 4
1 Power Fail (Emitter)
2 Power Fail (Collector)
3
Inhibit (Cathode)
4
Inhibit (Anode)
5
N/C
6
N/C
7
- VE Sense
8
- VE Sense
9
+VE Sense
10
+VE Sense
Mates with JST PHDR10VS housing and JST
SPHD-001T-P0.5 crimp
terminals
+VE
0.80
(20.2)
4.55 (115.5)
-VE
Input Connector CON 1
1
Line
2
Neutral
Pin 1
Detail B
Standby Board O/P
Connector Cons
JST S48-PH-K-S
Standby Output
(Option -A)
1
2
3
4
+5 V
+5 V
0V
0V
Mates with JST PHDR-4
housing and JST
SPH-002T-P0.5L crimp
terminals
Notes
1. Dimensions shown in inches (mm).
www.xppower.com
6
CHD250 Series
AC-DC Power Supplies
Mechanical Details
CHD250 Covered (-C)
0.39
(9.85)
M3 Mounting Holes
in 2 positions
4.72 (120.0)
0.93
(23.7)
Pin 2
Pin 1
Pin 10
Pin 9
Detail A
Signals Connector CON4
10 way JST B10B-PHDSS
5.50 ±0.02 (139.7 ±0.5)
1.75 (44.4)
0.59 (15.0)
Con 4
Output Voltage Control
A
Con 3
3.48 ±0.02
(88.5 ±0.5)
1
Con 1
-VE
1.73
(43.9)
2
Output Terminals
M4 Screws in
2 positions
torque to 8 lbs
(90 cNm) max.
+VE
1.03
(26.1)
Mates with Molex housing
09-50-1031 and Molex
series 5194 crimp terminals.
Con 2
4.72 (120.0)
0.39
(9.85)
M3 mounting holes in 4 positions
maximum penetration by screw to be
3.0 mm from bottom face of cover
Output Connector CON 3
1
+VE
2
-VE
1.97
(50.0)
Signals Connector CON 4
1 Power Fail (Emitter)
2 Power Fail (Collector)
3
Inhibit (Cathode)
4
Inhibit (Anode)
5
N/C
6
N/C
7
- VE Sense
8
- VE Sense
9
+VE Sense
10
+VE Sense
0.7
(19.3)
CHD250 Covered Standby Option (-AC)
0.39
(9.85)
M3 Mounting Holes
in 2 positions
4.72 (120.0)
0.93
(23.7)
Pin 2
Pin 1
Pin 10
Pin 9
Mates with JST PHDR10VS housing and JST
SPHD-001T-P0.5 crimp
terminals
Detail A
Signals Connector CON4
10 way JST B10B-PHDSS
5.50 ±0.02 (139.7 ±0.5)
1.75 (44.4)
Input Connector CON 1
1
Line
2
Neutral
0.59 (15.0)
Con 4
Standby Output
(Option -A)
Output Voltage Control
A
Con 3
3.48 ±0.02
(88.5 ±0.5)
1
Con 1
B
1.73
(43.9)
2
-VE
Output Terminals
M4 Screws in
2 positions
torque to 8 lbs
(90 cNm) max.
+VE
1.03
(26.1)
Con 2
0.39
(9.85)
4.72 (120.0)
M3 mounting holes in 4 positions
maximum penetration by screw to be
3.0 mm from bottom face of cover
1.97
(50.0)
0.7
(19.3)
Notes
1. Dimensions shown in inches (mm).
7
www.xppower.com
1
2
3
4
+5 V
+5 V
0V
0V
Mates with JST PHDR-4
housing and JST
SPH-002T-P0.5L crimp
terminals
CHD250 Series
AC-DC Power Supplies
Thermal Considerations
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must
not be exceeded. Temperature should be monitored using thermocouples placed on the hottest part of the component
(out of direct air flow). See below for component locations.
Temperature Measurements (At Ambient 50 °C)
Component
Max Temperature °C
T1 Coil
120 ° C
L3 Coil
120 ° C
C64
105 ° C
C53
105 ° C
Service Life
The estimated service life of the CHD250 Series is determined by the cooling arrangements and load conditions experienced in the end
application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a
key capacitors with in the product when installed by the end application. The worst case of the two figures should be taken as the indicative
service life in 24/7 operation.
The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this temperature.
Estimated Service Life vs Component Temperature
350000
Lifetime (Hrs)
300000
250000
200000
150000
100000
50000
0
105
95
85
75
65
L3
55
C64
C53 Temperature (°C)
180000
C53
160000
T1
Lifetime (Hrs)
140000
120000
100000
80000
60000
40000
20000
0
105
95
85
75
65
55
C64 Temperature (°C)
www.xppower.com
22 Dec 15