Issue: 1 Issue Date: 7/29/2016 Effective Date: 7/29/2016
Technical Data
Cordage Construction
Cordage Part Number
Component 1
a) Conductor
b) Insulation
Insulation Colors
Jacket
a) Color(s)
Cord Configuration
End 1
End 2
Insert
Mold Color
Contact
Coupling Nut
O-Ring
Available Lengths
Applicable SpecificationsCable
UL
Diameters (In)
102
5 COND
22 (26/36) AWG Bare Copper
0.010” Wall, Nom. mPPE
Black, White, Brown, Blue & Green/Yellow
0.040” Wall, Nom. PUR, Zero Halogen
SLATE
0.027
0.047
0.213
M12-A Female, 90 Degree
Cut End
Black TPU
Black TPU
Copper Alloy, Gold plated
Copper Alloy, Nickel plated
FKM
0.6, 1, 3, 5, 10, 15, 20 Meters
AWM/STYLE 20549
AWM/STYLE 21959
•••••••••••••••••••••••••••••••••••••••
Alpha Wire | 711 Lidgerwood Ave, Elizabeth, NJ 07207
www.alphawire.com | 1-800-52 ALPHA
80°C / 300 V RMS
90°C / 600 V RMS
1
Customer Specification
PART NO: AW0500102
M12-A Female 90 Degree
CSA International
Applicable SpecificationsCord Set
UL
CSA
Nominal Voltage
Rated Voltage
Ingress Protection
Environmental Compliance
CE
REACH Regulation (EC
1907/2006)
Physical & Mechanical
Properties
Temperature Range, Cord
Temperature Range,
Connector
Bend Radius
Pull Tension
Current Rating
Ordering Information
AW0500102 SL355
AW0500102 SL356
AW0500102 SL357
AW0500102 SL358
AW0500102 SL359
AW0500102 SL400
AW0500102 SL401
Standard Package
C(RU) AWM I/II A/B FT1
90°C / 600 V RMS
ANSI/UL 2238, Cable Assembly Extension
RU, UL File Number E485156
CSA-C22.2 No. 182.3, Special Use
Attachment Plugs, Receptacles and
Connectors
cRU, UL File Number E485156
60 V
63 V
IP67/NEMA 6P
All materials used in the manufacture of
this part meet the requirements of
European Directive 2011/65/EU regarding
the restriction of use of certain hazardous
substances in electrical and electronic
equipment. Exemption used; 6a.
This product does not contain Substances
of Very High Concern (SVHC) listed on the
European Union’s REACH candidate list in
excess of 0.1% mass of the item.
-50 to 90°C(static), -40 to 80°C (dynamic)
-25°C to +80°C
4X Cable Diameter (static), 6X Cable
Diameter (dynamic)
20.4 Lbs, Maximum
2.2 Amps @ 50°C
0.6 Meters
1.0 Meters
3.0 Meters
5.0 Meters
10.0 Meters
15.0 Meters
20.0 Meters
Each
Although Alpha Wire (“Alpha”) makes every reasonable effort to ensure their accuracy at the time of this publication, information and
specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
• •product
• • • • •availability.
• • • • • • Alpha
• • • •provides
• • • • • the
• • •information
• • • • • • •and
• • specification
•••••
specifications does not ensure
herein on an “AS IS” basis, with no
Alpha
Wire
| 711
Lidgerwood
Ave,
NJ 07207
representations or warranties,
whether
express,
statutory
or implied.
In noElizabeth,
event will Alpha
be liable any damages (including consequential,
2
www.alphawire.com
| 1-800-52
indirect, incidental, special, punitive, or exemplary
damages) whatsoever,
even if ALPHA
Alpha has been advised of the possibility of such damages,
whether in an action under contact, negligence or any other theory, arising out of or in connection with the use, or inability to use, the
information or specification described herein.
Similar pages