Click on Series name for product info on aimtec.com Series AM2LS-NZ 2 Watt | DC-DC Converter FEATURES: • • • • • • • • SMD Package Efficiency up to 86% Unregulated Industry Standard Pinout Single Output Models o o Operating temperature -40 C to +105 C Input / Output Isolation 1500 VDC Continuous Short Circuit Protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current Max (mA) Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 13.5-16.5 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 3.3 5 9 12 15 5 9 12 15 24 15 5 9 12 15 24 400 400 222 167 133 400 222 167 133 83 133 400 222 167 133 83 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 78 79 82 82 83 79 82 82 83 84 83 79 82 82 83 86 AM2LS-0503S-NZ AM2LS-0505S-NZ AM2LS-0509S-NZ AM2LS-0512S-NZ AM2LS-0515S-NZ AM2LS-1205S-NZ AM2LS-1209S-NZ AM2LS-1212S-NZ AM2LS-1215S-NZ AM2LS-1224S-NZ AM2LS-1515S-NZ AM2LS-2405S-NZ AM2LS-2409S-NZ AM2LS-2412S-NZ AM2LS-2415S-NZ AM2LS-2424S-NZ NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal 5 12 15 24 Reflected Input Ripple Current Absolute Max Input 5 Vin 12 Vin 15 Vin 24 Vin Filter Typical Maximum 4.5-5.5 10.8-13.2 13.5-16.5 21.6-26.4 15 9 18 21 30 Capacitor Units VDC mA VDC Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance www.aimtec.com F 051e R12.E Conditions Typical 60 sec 500VDC 1500 models >1000 20 Tel: +1 514 620 2722 1 of 3 Maximum Units VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2LS-NZ 2 Watt | DC-DC Converter Output Specifications Parameters Voltage accuracy Short Circuit protection Line voltage regulation Load voltage regulation (10% - 100% load) Temperature coefficient Ripple & Noise Conditions Typical 100% load (see tolerance chart) Maximum Units ±2.5 Continuous Auto Recovery 12 & 15 VDC input models 5 & 24 VDC Input models For ±1% of Vin 3.3V models only 3.3V 5V 9V 12 V 15 V 24 V 100% load At 20 MHz Bandwidth % 1 Sec % of Vin ±1.5 ±1.2 18 12 9 8 7 6 ±0.03 100 % o %/ C mV p-p * Products with 5Vdc and 24Vdc input voltage; the supply voltage must be discontinued at the end of short circuit duration. General Specifications Parameters Switching frequency Operating temperature Storage temperature Cooling Storage Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Maximum case temperature Conditions Typical Maximum Units 100% load With derating 3.3V & 5V above +71C Others +85C 100 300 KHz o C -40 to +105 o -55 to +125 Free air convection C Non Condensing 95 Epoxy resin (UL94-V0) 1.5 0.50 x 0.44 x 0.28 inches 12.70 x 11.20 x 7.25 mm o >3500K hrs (MIL-HDBK -217F, Ground Benign, t=+25 C)hours 1.5mm from case for 10 sec 300 130 Pin Out Specifications and Dimensions % RH g o C C o Single Output Models Front View Pin 1 2 3 4 5 6 7 8 - V Input + V Input No Pin .-V Output +V Output No Pin No Pin N.C. 8.3 (0.32) Side View Single Output 5.00 (0.19) 0º~10º angle 2.0 (0.08) 0.25 (0.01) 1.45 (0.06) Top View 0.88 (0.04) 12.70 (0.50) 7.62 (0.30) 11.20 8.30 (0.44) (0.32) 1 2.54 (0.10) www.aimtec.com F 051e R12.E Tel: +1 514 620 2722 2 of 3 0.60 (0.02) Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2LS-NZ 2 Watt | DC-DC Converter Single Recommended Circuits (EMI Class B) Vin+ Capacitor selection Table Vout C2 3.3 V 10 µF 5V 10 µF 9V 4.7 µF 12 V 2.2 µF 15 V 1 µF 24V 0.47 µF Vo+ LDM 6.8µH C1 4.7µF 50V C2 Vin- Vo- Load Accuracy Tolerance Graph Derating Free Air Convection 10 % Rated Output Voltage 71 ºC Typic al loa 100 d line Output Voltage Accuracy% -2.5 % -7.5 % 70 % 10 % 85 ºC +2.5 % 50 % Output Current % (Nominal Input) 100 % Output Power % 5% 3.3V & 5V 80 Others Safe Operating Area 60 50% 40 20 71C 0 -50 -30 0 40 105C 85C 80 100 120 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4 . All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.E Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only