AIMTEC AMEC15-5SMAZ 15 watt | ac-dc / dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AMEC15-MAZ
15 Watt | AC-DC / DC-DC Converter
FEATURES:





Connector on Input & Output
Operating temperature: -40 to +80°C
Over load, Over Voltage, Short Circuit Protection
Optional DIN Rail mounting bracket
Universal input: 90-264VAC, 47-440Hz





RoHS compliant
Soft start
Energy Star compliant
CE, cULus, CB approvals
4000VAC I/O Isolation
CB
Models
Single output
Model
AMEC15-3.3SMAZ
AMEC15-5SMAZ
AMEC15-12SMAZ
AMEC15-15SMAZ
AMEC15-24SMAZ
Input Voltage
(VAC/Hz)
Output
Voltage
(V)
Input voltage
(VDC)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
130-370
130-370
130-370
130-370
130-370
Input Voltage
(VAC/Hz)
Input voltage
(VDC)
Output
Current
max (A)
Maximum
Capacitive Load
(µF)
3
3
1.25
1
0.63
4700
2200
1000
680
470
Output
Voltage
(V)
Output
Current
max (A)
Maximum
Capacitive Load
(µF)
±5
±12
±15
±1.5
±0.63
±0.5
3.3
5
12
15
24
Efficiency
(%)
115
230
VAC
VAC
74
75
81
81
83
74
76
82
83
83
Models
Dual output
Model
AMEC15-5DMAZ
AMEC15-12DMAZ
AMEC15-15DMAZ
90-264/47-440
90-264/47-440
90-264/47-440
130-370
130-370
130-370
±1000
±470
±330
Efficiency
(%)
115
230
VAC
VAC
78
81
82
79
82
83
Input Specifications
Parameters
Current (Full Load)
Inrush current <2ms
Leakage current
External Fuse
Input Dissipation
Under Voltage Protection
Conditions
Typical
115VAC
230VAC
115 VAC
230 VAC
115 VAC
264 VAC
recommend slow blow type
115 / 230 VAC
Maximum
Units
350
180
20
30
0.1
0.2
mA
mA
A
A
mA
mA
A
W
VAC
Maximum
Units
2
൑0.2
85
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Cross regulation (dual output)
Transient Recovery Time
Transient Recovery Deviation
Ripple & Noise*
Hold-up time
Conditions
Typical
LL-HL
0-100%
25% load - 1st out, 100% load – 2nd out
25% load step
3.3/5V models
12/15V models
24V models
min
±2
±1
±1
±5
200
±2
75
100
150
20
%
%
%
%
µs
% of Vout
mVp-p
ms
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) and 47μF (E/C) parallel capacitor.
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEC15-MAZ
15 Watt | AC-DC / DC-DC Converter
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation resistance
Typical
60 sec
Rated
Units
4000
VAC
MΩ
Maximum
Units
>1000
General Specifications
Parameters
Conditions
Switching frequency
Protection Class
Start up time
Over load protection
Over voltage protection
Short Circuit protection
Case Material
Operating temperature
Storage temperature
Max Case temperature
Temperature coefficient
Cooling
Humidity
Weight
Dimensions (L x W x H)
MTBF
Typical
Foldback
With derating over 55 oC (10CFM)
132
Class II
350
130
Zener diode clamp
Auto recovery
Metal
-40 to +80
-50 to +100
KHz
mS
%
oC
oC
100
oC
% / oC
±0.02
Free air convection
95
100
3.62 x 2.56 x 0.94 inches
92.0 x 65.0 x 24.0 mm
> 400 000hrs (MIL-HDBK -217F, t=+25oC)
% RH
g
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Parameters
Shock
Vibrations
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety & EMC Specifications
Parameters
Agency approvals
cULus, CE, CB
Standards
Medical Electrical Equipment
Information technology Equipment
Harmonic Current Emissions
EMI - Conducted and radiated emission
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
www.aimtec.com
F 052e R8.U
IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-M90
EN 60950-1:2006+A11:2009
IEC/EN 61000-3-2, Class A
EN55011, class B
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 3
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 2
IEC 61000-4-8 Level 2
IEC 61000-4-11
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEC15-MAZ
15 Watt | AC-DC / DC-DC Converter
Derating
A
Output Power (%)
A
B
100
Free Air
Convection
40 º C
80
B
60
40
10 CFM
55 º C
Safe Operating Area
20
0
- 40 - 20
0
20
40
60
80
85
100
Ambient Temperature º C
Pin Out Specifications
Pin
Single
Dual
1
2
3
4
5
AC Input (N)
AC Input (L)
-V Output
No Connection
+V Output
AC Input (N)
AC Input (L)
-V Output
Common
+V Output
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEC15-MAZ
15 Watt | AC-DC / DC-DC Converter
24
(0.94)
Dimensions
PCB Mounting
Screw
PCB Mounting
Screw
Side View
PCB
Mylar Film
Bracket
Mountin
g Screw
PCB
Mylar Film
2.6 mm Max
Customer Chassis
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEC15-MAZ
15 Watt | AC-DC / DC-DC Converter
Mating Connectors with Wire (included)
DC Output Mating
Connector
200 ± 0.5
Top
View
3 ± 0.5
Side
View
AC Input Mating
Connector
Alternative
Connector Side
View
200 ± 0.5
Top
View
Side
View
3 ± 0.5
Alternative
Connector Side
View
Optional DIN Rail Bracket
NOTE: 1.Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.U
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages