EMD-BL-PTC(-PT) Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 © PHOENIX CONTACT - 2016-05-10 Description Features Safety and system availability requirements are constantly on – the increase – across all industries. Processes are becoming more and more complex, not only in machine building and the chemical industry but also in building technology. The demands placed on energy technology are also constantly on the rise. It is only by continuously monitoring key network and system parameters that error-free and therefore cost-effective operation can be achieved. Electronic monitoring relays from the EMD series are available for a wide range of monitoring tasks so that the consequences of errors can be avoided or kept within limits. The operating states are signaled via color LEDs and any errors that occur can be sent to a controller via a floating contact or can shut down a section of the system. All device versions are equipped with response delays so that measured values outside the set monitoring range can be briefly tolerated. Winding temperature monitoring WARNING: Risk of electric shock Never carry out work when voltage is present. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. EMD-BL-PTC(-PT) 2 Ordering data Description Type Order No. Electronic monitoring relay for temperature monitoring EMD-BL-PTC-PT 2906253 1 Electronic monitoring relay for temperature monitoring EMD-BL-PTC 2906252 1 3 Pcs./Pkt. Technical data Input data Input name Measuring input Maximum input voltage ≤ 4 V DC (connection terminal blocks: T1 and T2) Maximum temperature coefficient < 0.05 %/K Function Winding temperature monitoring Basic accuracy ± 10 % (of scale end value) Total cold resistance ≤ 1.5 kΩ Response value ≥ 3.6 kΩ (Relay drops out) Release value ≤ 1.6 kΩ (Relay picks up) Short-circuit detection < 20 Ω Recovery time > 300 ms Output data Contact type 1 floating PDT Maximum switching voltage 250 V AC (in acc. with IEC 60947-5-1) Interrupting rating (ohmic load) max. 1250 VA (5 A/250 V AC) Output fuse 5 A (fast-blow) Supply Supply voltage 230 V AC (-15 % ... +10 %) Frequency range 50 Hz ... 60 Hz Nominal power consumption 3.5 VA (0.5 W) General data Mechanical service life 15 x 106 cycles Service life, electrical 1 x 105 cycles Switching frequency ≤6 Voltage drop > 30 % (Relative to the supply voltage) Operating mode 100% operating factor Degree of protection IP40 (housing) / IP20 (connection terminal blocks) Degree of pollution 2 (IEC 60947-5-1) Overvoltage category III (IEC 60947-5-1) Mounting on standard DIN rail NS 35 in accordance with EN 60715 Mounting position any Width 17.5 mm Height 88 mm Depth 65.5 mm Type of housing Polyamide PA66, self-extinguishing Color gray 107385_en_00 PHOENIX CONTACT 2 EMD-BL-PTC(-PT) Connection data Push-in-/Spring-cage connection Screw connection Conductor cross section, solid 0.14 mm² ... 2.5 mm² 0.5 mm² ... 2.5 mm² Conductor cross section, flexible 0.14 mm² ... 2.5 mm² 0.5 mm² ... 2.5 mm² AWG 26 ... 14 20 ... 14 Stripping length 8 mm 8 mm Tightening torque 1 Nm Ambient conditions Ambient temperature (operation) -25 °C ... 55 °C Ambient temperature (storage/transport) -25 °C ... 70 °C Permissible humidity (operation) 15 % ... 85 % Climatic class Conformance / approvals Conformance CE-compliant UL, USA / Canada Conformance with EMC Directive 2004/108/EC (valid until April 19, 2016) / 2014/30/EU (valid from April 20, 2016) Noise immunity according to EN 61000-6-2 Noise emission according to EN 61000-6-3 Conformance with Low Voltage Directive 2006/95/EC (valid until April 19, 2016) / 2014/35/EU (valid from April 20, 2016) Low voltage switchgear according to 107385_en_00 EN 60947-5-1 PHOENIX CONTACT 3 EMD-BL-PTC(-PT) 4 Block diagram U = 230 V AC 12 14 T1 T2 11 A1 5 A2 Safety notes WARNING: Risk of electric shock Never carry out work when voltage is present. 6 Structure 1 2 3 A1 LED: failure LED: supply U Snap-on foot for DIN rail mounting A2 T1 3 T2 2 EMD-BL-PTC-PT 1 Failure U 7 Installation WARNING: Risk of electric shock Never carry out work when voltage is present. The module can be snapped onto all 35 mm DIN rails according to EN 60715. 107385_en_00 PHOENIX CONTACT 4 EMD-BL-PTC(-PT) 8 Diagnostics The LEDs indicate the following error states: "U" LED (Green) – LED ON: Supply voltage present "Failure" LED (red): – LED ON: indicates error 9 Connection examples U A1 A2 T1 T2 A1 11 R A2 12 14 11 12 10 14 Function Temperature Monitoring of the Motor Winding LED FAILURE 3,6 k 1,6 k PTC R 107385_en_00 If the PTC total resistance is less than 3.6 kΩ (normal temperature of the motor) when the supply voltage is applied, the output relay R activates. If the total resistance rises over 3.6 kΩ, the output relay R deactivates. The output relay R reactivates when the PTC total resistance has fallen below 1.6 kΩ. PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com 5