Embedded Power for Business-Critical Continuity Rev. 06.15.09_11 AED/ALD13B50 of 3 AED/ALD13B50 1/16th Brick IBC Series Total Power: 150 Watts Input Voltage: 38 - 60 Vdc Output Voltage: 12 Vdc Electrical Specifications Input Special Features • Intermediate Bus Converter for Front End (DPA) Distributed Power Architecture application • High efficiency (95% Typical) • Industry standard package 16th Brick 0.90” x 1.30” • High capacitive load limit on start-up • Output Enable Pin • Undervoltage lockout • Over Temperature Protection • Meets Basic Insulation • EU directive 2002/95/EC compliant for RoHS Input range: Efficiency: 8 V to 60 V 3 95%@ 12 V (typical) Over Voltage Protection: 67 V typical Input UVLO: 33 V to 38 V Output Output current: Output Voltage over line, load and temperature: Noise/ripple1: Over current limit: 13 A max 8.7 V to 15 V 180 mV (typical) Auto-restart Over temperature protection: 110 °C minimum (autorecovery) Switching frequency: 165 kHz Control Enable: TTL compatible (positive or negative enable logic) Isolation Voltage: Input to Output: 2000 Vdc max Environmental Specifications Safety • UL, cUL: 60950 • TUV: EN60950 Operating ambient temperature range: Storage temperature: MTBF: -40 °C to +85 °C ambient -55 °C to +125 °C > 1 million hours Embedded Power for Business-Critical Continuity Rev. 06.15.09_11 AED/ALD13B50 of 3 Ordering Information Input Voltage Output Voltage Output Current Efficiency2 Model Number 38 - 60V 12 V 13 A 95% Typ A(X)D13B50(N)-(6)(L) Options: (X) : (N) : (6) : (L) : “L” “E” “N” “-6” “L” = = = = = Open Frame / Low Profile Heatplate Construction Designates Negative Logic Enable (default is Positive Enable with no suffix “N” required) 3.7 mm nominal pin length (default is 5 mm nominal pin length with no suffix “-6” required) RoHS Compliant (RoHS 6) Pin Connections Single Output 1. +Vin 2. Enable 3. -Vin 4. -Vout 5. Blank 6. Blank 7. Blank 8. +Vout Notes: 1. 20 MHz bandwidth. External 10 uF tant. capacitor in parallel with 1 uF ceramic capacitor placed across the output and secondary return ground. 2. Efficiency measurements are typical values taken at 48 V input, nominal output, full load and TA = 25 °C. 3. All specifications are typical at nominal line, full load and TA = 25 °C unless otherwise noted. 4. All specifications subject to change without notice. 5. Mechanical drawings are for reference only. Dimensions are in inches [millimeters]. Pin placement tolerance ± 0.005 [0.127]. Mechanical Tolerance ± 0.02 [0.5]. Pin diameter, Ø = 0.06” for Pin 4 (-Vout) and Pin 8 (+Vout), the rest of the pins are Ø = 0.04”. 6. Technical Reference Notes should be consulted for detailed information when available. 7. Warranty 1yr. Mechanical Drawings AED13B50-L AED13B50-SL Embedded Power for Business-Critical Continuity ALD13B50-L Americas Rev. 06.15.09_11 AED/ALD13B50 of 3 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.PowerConversion.com techsupport.embeddedpower @emerson.com ALD13B50-SL While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co.