Dallas DS2409P Microlan coupler Datasheet

DS2409
MicroLAN Coupler
www.dalsemi.com
PIN ASSIGNMENT
FEATURES
§ Low impedance coupler to create large
common-ground, multi-level MicroLAN
networks
§ Keeps inactive branches pulled high to 5V
§ Simplifies network topology analysis by
logically decoupling devices on active
network segments
§ Conditional search for fast event signaling
§ Auxiliary 1-WireTM line to connect a memory
chip or to be used as digital input
§ Programmable, general purpose open drain
control output
§ Communicates at 16.3k bits per second
§ Unique, factory-lasered and tested 64-bit
registration number (8-bit family code + 48bit serial number + 8-bit CRC tester) assures
absolute traceability because no two parts are
alike
§ 8-bit family code specifies device
communication requirements to bus master
§ Built-in multidrop controller ensures
compatibility with other MicroLAN products
§ Operating temperature range from -40°C to
+85°C
§ Compact, low cost 6-pin TSOC surface mount
package
6-PIN TSOC PACKAGE
1
6
2
5
3
4
TOP VIEW
3.7 X 4.0 X 1.5 mm
SIDE VIEW
PIN DESCRIPTION
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
GND
1-Wire in
Main 1-Wire out
Auxiliary 1-Wire out
Control Output
VDD
ORDERING INFORMATION
DS2409P
6-pin TSOC package
DESCRIPTION
The MicroLAN coupler is an essential component to build and control 1-Wire MicroLAN networks with
multi-level branching. In contrast to approaches that switch the ground line, the coupler maintains a
common ground level for the whole network and keeps the inactive segments powered. This simplifies
supplying central or local power for additional circuitry and prevents loss of status of parasitically
powered devices. It also avoids disrupting communication caused by the parasitic power supply of 1-Wire
devices after activating a branch. The coupler does not contain any user-programmable memory. To label
a branch one can connect any 1-Wire memory device to the auxiliary 1-Wire output of the coupler. Both
the main and the auxiliary 1-Wire output are supported by a “smart-on” command. This command
generates a reset/presence sequence on the selected output before the electronic switch closes the contact
to the 1-Wire bus. This way the bus master can apply a ROM function command (optionally followed by
a memory function) to the devices on the just activated segment with all other devices in the network
1 of 18
102199
DS2409
remaining deselected. This significantly speeds up the analysis of topology and population in a
continuously changing network. The coupler also supports the bus master in detecting arrivals on the
inactive segments of the network by responding to the conditional search command. The control output
can be used to optically signal the on/off state of a branch or, together with the auxiliary output, for
handshaking in dual-master applications. The network size can be maximized by using a DS2480 line
driver at the bus master’s serial interface. The DS2480 compensates for the rising ground level caused by
the non-zero on-resistance of couplers in multi-level networks.
OVERVIEW
The DS2409 Coupler provides a means to create large MicroLAN networks with additional control
capability provided by an open-drain N-channel MOSFET that can be remotely switched via
communication over the 1-Wire bus (Figure 1). An auxiliary output can be used to label the branch by
connecting a programmed 1-Wire memory chip or as digital input. The DS2409 contains a factory-lasered
registration number that includes a unique 48-bit serial number, an 8-bit CRC, and an 8-bit family code
(1FH). The 64-bit ROM portion of the DS2409 not only creates an absolutely unique electronic
identification for the device itself but also is a means to locate and address the device in order to exercise
its control functions.
The DS2409 uses the standard Dallas Semiconductor 1-Wire protocol for data transfers (Figure 2), with
all data being read and written least significant bit first. Communication to and from the DS2409 requires
a single bi-directional line that is typically a port pin of a microcontroller. The 1-Wire bus master
(microcontroller) must first issue one of five ROM function commands: 1) Read ROM, 2) Match ROM,
3) Search ROM, 4) Skip ROM, or 5) Conditional Search ROM. These commands operate on the 64-bit
lasered ROM portion of each device and can singulate a specific device if many are present on the 1-Wire
line as well as indicate to the bus how many and what type of each device is present. After a ROM
function command is successfully executed, the control functions of the device can be exercised via the 1Wire bus.
BLOCK DIAGRAM Figure 1
2 of 18
102199
DS2409
64-BIT LASERED ROM
Each DS2409 contains a unique ROM code that is 64 bits long. The first eight bits are a 1-Wire family
code. The next 48 bits are a unique serial number. The last eight bits are a CRC of the first 56 bits. (See
Figure 3.) The 1-Wire CRC of the lasered ROM is generated using the polynomial X8 + X5 + X4 + 1.
Additional information about the Dallas Semiconductor 1-Wire Cyclic Redundancy Check is available in
the Book of DS19xx iButton Standards. The 64-bit ROM and ROM Function Control section allow the
DS2409 to operate as a 1-Wire device and follow the 1-Wire protocol detailed in the section “1-Wire Bus
System”. The functions required to exercise the control functions of the DS2409 are not accessible until
the ROM function protocol has been satisfied. This protocol is described in the ROM functions flow
chart (Figure 7). The 1-Wire bus master must first provide one of the five ROM function commands.
After a ROM function sequence has been successfully executed, the bus master may then provide any one
of the function commands specific to the DS2409 (Figure 5).
HIERARCHICAL STRUCTURE FOR 1-WIRE PROTOCOL Figure 2
64-BIT LASERED ROM Figure 3
MSB
8-Bit CRC Code
MSB
48-Bit Serial Number
LSB MSB
3 of 18
LSB
8-Bit Family Code (1FH)
LSB MSB
LSB
102199
DS2409
1-WIRE CRC GENERATOR Figure 4
CONTROL FUNCTION COMMANDS
The “Control Function Flow Chart” (Figure 5) describes the protocols necessary for controlling the main
and auxiliary output as well as the control output of the DS2409. The 1-Wire Function Control section
and the Coupler Function Control section combine to interpret the commands issued by the bus master
and create the correct control signals within the device. Depending on the complexity of function to be
exercised, the 1-byte command code may require one or two more bytes being sent by the bus master.
Switching one branch on implies that the other branch is automatically switched off. At power-on, both
branches are switched off. Each command flow includes at least one byte of feedback information for the
bus master to check if the command was understood and executed.
STATUS READ/WRITE [5Ah]
This command should be sent to the device after powering up unless the default settings are adequate for
the application. Following the command code, the bus master has to send the status control byte. The bus
master will then read the status info byte from the device. The confirmation byte is identical to the status
info byte. Tables 1 and 2 show the bit assignments in both bytes.
At power-on the device will be in the auto-control mode and the control output will be assigned to the
main output. The control output can be assigned to the auxiliary output by setting bit 6 of the status
control byte to a 1. For manual operation of the control output one has to select manual mode (bit 5 = 1).
The value of bit 7 of the status control byte will then determine the status of the control output. A 1 for bit
7 will make the transistor conducting, a 0 will turn it off (non-conducting). To change the status of the
device, both bits 3 and 4 of the status control byte have to be 0. Otherwise the settings will remain
unchanged. In any case, the status info byte will reflect the currently valid settings including the changes
that might have been made with the status control byte.
The status info byte allows the bus master to verify the actual status of each output (STAT,
active/inactive, on/off) and the static level at the main and auxiliary output (LEVL, 1 for normal, 0 in case
of a short). If a 1-Wire output is inactive and a low-going edge is encountered during this time, the
DS2409 will set the event flag (EVNT) the status info byte. Each output has its own event flag. The event
flags are cleared with the All Lines Off command. Bit 7 of the status info byte tells if the device is autocontrol mode or manual mode. Depending on the value of this bit, the information in bit 6 (CNTR.
STAT) either reports the association of the control output to a particular output (auto-control mode) or the
status of the transistor at the control output.
4 of 18
102199
DS2409
STATUS CONTROL BYTE Table 1
7
DATA
X
X
R/ W
MODE
CNTR.
SEL.
DATA
X
0-2
3-4
5
6
7
6
CNTR.
SEL.
5
4
3
2
1
0
MODE
R/ W
R/ W
X
X
X
don’t care
Write control: both bits must be 0 to change the status.
control output mode selection: 0 = auto-control mode (default), 1 = manual mode
control output association (auto-control mode): 0 = main (default), 1 = auxiliary
Value to be written to control output (manual mode only): don’t care otherwise
STATUS INFO BYTE Table 2
7
MODE
0
1
2
3
4
5
6
7
MAIN
STAT
MAIN
LEVL
AUX.
STAT
AUX.
LEVL
EVNT
MAIN
EVNT
AUX.
CNTR.
STAT
MODE
6
CNTR.
STAT
5
EVNT
AUX.
4
EVNT
MAIN
3
AUX.
LEVL
2
AUX.
STAT
1
MAIN
LEVL
0
MAIN
STAT
status of main output: 0 = active (connected to bus master), 1 = inactive
voltage sensed at main output: 0 = low, 1 = high (see note)
status of auxiliary output: 0 = active (connected to bus master), 1 = inactive
voltage sensed at auxiliary output: 0 = low, 1 = high (see note)
event flag for main output: 0 = no event, 1 = negative edge sensed since inactive
event flag for aux. Output: 0 = no event, 1 = negative edge sensed since inactive
if auto-control mode: control output association, 0 = main, 1 = auxiliary
if manual mode: 0 = output transistor off, 1 = output transistor on
control output mode: 0 = auto-control mode, 1 = manual mode
Note: Data is valid only if the output is decoupled from the 1-Wire input.
ALL LINES OFF [66h]
This command is used to deactivate the currently active 1-Wire output and to clear both event flags or to
end a discharge cycle initiated by the Discharge Lines command. Before issuing this command, one
should read the status and check the event flags of both, the main and the auxiliary output. Otherwise one
might inadvertently clear the event flag without having taken appropriate action. If the DS2409 is in autocontrol mode, the transistor at the control output will be switched off (non-conducting). At power-on, the
device will automatically perform the All Lines Off command. In contrast to a power-on cycle, the All
Lines Off command does not clear the Mode and Control Select bits.
5 of 18
102199
DS2409
DISCHARGE LINES [99h]
There may be situations where one has to force a power-on reset for parasitically powered 1-Wire devices
connected to the main or auxiliary output of the DS2409. For this purpose the Discharge Lines command
has been implemented. This command first deactivates the output lines and then turns on the pulldown
transistors of both, the main and the auxiliary outputs. This state will be maintained until the bus master
accesses the coupler again and issues a different control function command. The duration of the
discharge time should be 100 ms minimum and is controlled solely by the bus master.
Although any of the other control function commands will end the discharge cycle, it is recommended to
use the All Lines Off or Status Read/Write command to do so. This will allow the discharged lines to
fully recharge and prevent a sudden voltage droop on the active part of the network in case of a Direct-On
Main command. This precaution is not necessary with the Smart-On command.
DIRECT-ON MAIN [A5h]
The Direct-on Main command is typically used to activate the main 1-Wire output to subsequently issue a
reset pulse and access a device residing on the segment of the MicroLAN connected to the Main output of
the DS2409. If this command is received, the DS2409 will automatically set the auxiliary output to
inactive. Depending on the currently valid device status settings, the transistor at the control output may
change state (see Status Read/Write command).
SMART-ON MAIN [CCh]
When analyzing huge MicroLAN networks for changes in population it may be useful to limit the number
of devices participating in a Search ROM command. The smaller the number of participants, the faster
the responding devices are identified. The DS2409 supports the bus master in this process with the SmartOn Main command. As a preparation for the subsequent steps, the first action of the Smart-On Main
command is deactivating the main output.
Compared to the Direct-On Main command, the Smart-On Main requires the bus master to follow the
function command with 16 more time slots. The first 8 time slots (reset stimulus) are translated by the
DS2409 as a reset low time on the Main 1-Wire output. Now the bus master reads the reset response byte.
This generates the reset high time where devices connected to the Main 1-Wire output may assert their
presence pulse. If a presence pulse was found, several of the most significant bits of the reset response
byte will be zeros. After these 16 time slots are completed the Main 1-Wire output will be activated (=
through-connected to the 1-Wire input of the DS2409). Now only the devices on the newly activated
segment of the MicroLAN are ready to receive a ROM function command optionally followed by a
memory function command. All other devices in the network will remain silent until the next reset pulse
is issued.
As with the Direct-On command, the Smart-On Main command will automatically set the auxiliary
output to inactive. Depending on the currently valid device status settings, the transistor at the control
output may change state (see Status Read/Write command). If the Smart-On Main command is terminated
by a 1-Wire reset pulse while receiving the reset stimulus, the DS2409 will immediately turn off the
pulldown transistor and let the output line go high.
SMART-ON AUXILIARY [33h]
This command works essentially the same way as the Smart-On Main command, but it affects the
auxiliary 1-Wire output. After the reset response byte is received by the bus master, the auxiliary output is
activated and the main output becomes inactive. Depending on the currently valid device status settings,
the transistor at the control output may change state (see Status Read/Write command).
6 of 18
102199
DS2409
FUNCTION COMMAND FLOW CHART Figure 5
7 of 18
102199
DS2409
FUNCTION COMMAND FLOW CHART Figure 5 cont’d
8 of 18
102199
DS2409
HARDWARE CONFIGURATION Figure 6
1-WIRE BUS SYSTEM
The 1-Wire bus is a system which has a single bus master and one or more slaves. In all instances the
DS2409 behaves as a slave. The discussion of this bus system is broken down into three topics: hardware
configuration, transaction sequence, and 1-Wire signaling (signal types and timing). A 1-Wire protocol
defines bus transactions in terms of the bus state during specified time slots that are initiated on the
falling edge of sync pulses from the bus master. For a more detailed protocol description, refer to Chapter
4 of the Book of DS19xx iButton Standards.
Hardware Configuration
The 1-Wire bus has only a single line by definition; it is important that each device on the bus be able to
drive it at the appropriate time. To facilitate this, each device attached to the 1-Wire bus must have open
drain or 3-state outputs. The 1-Wire input of the DS2409 is open drain with an internal circuit equivalent
to that shown in Figure 6. A multidrop bus consists of a 1-Wire bus with multiple slaves attached. The 1Wire bus has a maximum data rate of 16.3k bits per second and requires a pullup resistor of
approximately 1.5k? or a DS2480 driver for MicroLAN applications.
The idle state for the 1-Wire bus is high. If for any reason a transaction needs to be suspended, the bus
MUST be left in the idle state if the transaction is to resume. If this does not occur and the bus is left low
for more than 120 µs, one or more of the devices on the bus may be reset. The DS2409 may perform a
power-on reset cycle and deactivate both 1-Wire outputs if the 1-Wire input is low for minimum 8 ms. A
low time of 12 ms or more will always cause a power-on reset cycle.
Transaction Sequence
The protocol for accessing the DS2409 via the 1-Wire port is as follows:
• Initialization
• ROM Function Command
• Control Function Command
INITIALIZATION
All transactions on the 1-Wire bus begin with an initialization sequence. The initialization sequence
consists of a reset pulse transmitted by the bus master followed by presence pulse(s) transmitted by the
slave(s). The presence pulse lets the bus master know that the DS2409 is on the bus and is ready to
operate. For more details, see the “1-Wire Signaling” section.
9 of 18
102199
DS2409
ROM FUNCTION COMMANDS
Once the bus master has detected a presence, it can issue one of the five ROM function commands. All
ROM function commands are eight bits long. A list of these commands follows (refer to flowchart in
Figure 7):
Read ROM [33h]
This command allows the bus master to read the DS2409s 8-bit family code, unique 48-bit serial number,
and 8-bit CRC. This command can only be used if there is a single DS2409 on the bus. If more than one
slave is present on the bus, a data collision will occur when all slaves try to transmit at the same time
(open drain will produce a wired-AND result). The resultant family code and 48-bit serial number will
usually result in a mismatch of the CRC.
Match ROM [55h]
The match ROM command, followed by a 64-bit ROM sequence, allows the bus master to address a
specific DS2409 on a multidrop bus. Only the DS2409 that exactly matches the 64-bit ROM sequence
will respond to the following memory function command. All slaves that do not match the 64-bit ROM
sequence will wait for a reset pulse. This command can be used with a single or multiple devices on the
bus.
Skip ROM [CCh]
This command can save time in a single drop bus system by allowing the bus master to access the control
functions without providing the 64-bit ROM code. If more than one slave is present on the bus and a read
command is issued following the Skip ROM command, data collision will occur on the bus as multiple
slaves transmit simultaneously (open drain pulldowns will produce a wired-AND result).
Search ROM [F0h]
When a system is initially brought up, the bus master might not know the number of devices on the 1Wire bus or their 64-bit ROM codes. The search ROM command allows the bus master to use a process
of elimination to identify the 64-bit ROM codes of all slave devices on the bus. The search ROM process
is the repetition of a simple 3-step routine: read a bit, read the complement of the bit, then write the
desired value of that bit. The bus master performs this simple, 3-step routine on each bit of the ROM.
After one complete pass, the bus master knows the contents of the ROM in one device. The remaining
number of devices and their ROM codes may be identified by additional passes. See Chapter 5 of the
Book of DS19xx iButton Standards for a comprehensive discussion of a search ROM, including an actual
example.
Conditional Search ROM [ECh]
This ROM command works exactly as the normal ROM Search, but it will identify only devices that
encounter certain conditions. The DS2409 will respond to this command only if the event flag for the
main output is set (see Status Read/Write command). The event flag is cleared with the All Lines Off
command.
10 of 18
102199
DS2409
ROM FUNCTIONS FLOW CHART Figure 7
11 of 18
102199
DS2409
1-WIRE SIGNALING
The DS2409 requires strict protocols to ensure data integrity. The protocol consists of four types of
signaling on one line: Reset Sequence with Reset Pulse and Presence Pulse, Write 0, Write 1 and Read
Data. All these signals except presence pulse are initiated by the bus master. The initialization sequence
required to begin any communication with the DS2409 is shown in Figure 8. A reset pulse followed by a
presence pulse indicates the DS2409 is ready to send or receive data given the correct ROM command
and control function command. The bus master transmits (TX) a reset pulse (tRSTL, minimum 480 µs).
The bus master then releases the line and goes into receive mode (RX). The 1-Wire bus is pulled to a high
state via the pullup resistor. After detecting the rising edge on the data line, the DS2409 waits (tPDH, 15-60
µs) and then transmits the presence pulse (tPDL, 60-240 µs).
INITIALIZATION PROCEDURE “RESET AND PRESENCE PULSES” Figure 8
*In order not to mask interrupt signaling by other devices on the 1-Wire bus, tRSTL + tR should always be
less than 960 µs.
**The slew rate of the Presence Pulse is actively limited by the DS2409 to 1V/µs typically to minimize
ringing. The slope of all other edges is controlled by the 1-Wire bus driver at the host.
READ/WRITE TIME SLOTS
The definitions of write and read time slots are illustrated in Figure 9. All time slots are initiated by the
master driving the data line low. The falling edge of the data line synchronizes the DS2409 to the master
by triggering a delay circuit in the DS2409. During write time slots, the delay circuit determines when the
DS2409 will sample the data line. For a read data time slot, if a “0” is to be transmitted, the delay circuit
determines how long the DS2409 will hold the data line low overriding the 1 generated by the master. If
the data bit is a “1”, the device will leave the read data time slot unchanged.
12 of 18
102199
DS2409
READ/WRITE TIMING DIAGRAM Figure 9
13 of 18
102199
DS2409
USAGE EXAMPLE
Configuration: A bus master controls a MicroLAN consisting of a trunk with many DS2409s that create
branches. Each of the DS2409s has a DS2430A connected to its auxiliary output to label its physical
location in the network (see Figure 10). iButton devices are constantly arriving at or departing from the
branches.
Task: Identify one branch where an iButton has arrived and get the branch’s physical location. Determine
the population on that particular branch.
STEP
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
MASTER MODE
DATA (LSB FIRST)
COMMENTS
TX
Reset
Reset pulse (480–960 µs)
RX
Presence
Presence pulse
TX
ECh
Issue “conditional search ROM” command
RX/RX/TX
for each of the 64 ROM bits Identify and access one of the qualifying devices
TX
33h
Issue Smart-On Auxiliary command
TX
FFh
Send reset stimulus
RX
<data byte>*
Get reset response byte with presence info
RX
33h
Get confirmation byte
TX
CCh
Issue “skip ROM” command
TX
F0h
Issue “read memory” command
RX
<32 data bytes>
Get branch location information (DS2430A)
TX
Reset
Reset pulse
RX
Presence
Presence pulse
TX
55h
Issue “Match ROM” command
TX
<8 byte ROM ID>
Access the previously identified coupler
TX
CCh
Issue Smart-On Main command
TX
FFh
Send reset stimulus
RX
<data byte>*
Get reset response byte with presence info
RX
CCh
Get confirmation byte
TX
F0h
Issue “search ROM” command
RX/RX/TX
for each of the 64 ROM bits Identify one of the devices connected
TX
Reset
Reset pulse
RX
Presence
Presence pulse
TX
55h
Issue “Match ROM” command
TX
<8 byte ROM ID>
Access the previously identified coupler
TX
66h
Send all lines off command
RX
66h
Get confirmation byte
TX
Reset
Reset pulse
RX
Presence
Presence pulse
repeat steps 12 to 21 for each of the remaining devices on the branch of the identified coupler
* 00h or 01h if presence pulse, FFh if no presence pulse
Note: The sequence of steps 12 to 21 logically decouples all other devices residing on the trunk from
responding to the search ROM command. The All Lines Off command is required to clear the event flag
that made the device respond to the conditional search command.
14 of 18
102199
DS2409
APPLICATION EXAMPLES
Figures 10 and 11 show two application examples of the DS2409 MicroLAN Coupler. A single trunk
with branches is the typical topology of an access control system with the iButtons being the electronic
keys required for admittance. The host computer runs a program that scans the devices on the trunk for
events (conditional search). When somebody touches the probe with an iButton, this will set the event
flag of the main line and the coupler will respond. The ID chip represents the DS2430A that labels the
access point. The 64-bit ROM ID of the arriving iButton is the key for the entrance. In a real access
control application, the LED will be replaced by a solenoid that opens the lock under software control
(manual mode). The same network topology could be used for an inventory control system with the
branches representing individual shelves of a rack. The iButtons would be electronic tags mounted on
objects sitting on the shelves. The LED would guide the warehouse worker in placing the objects onto the
right shelf.
The dual-master system realizes a master to master communication path via the 1-Wire bus. The DS1996
Memory iButton serves as a temporary storage for the data packets to be exchanged. When idle, both
main outputs as well as the auxiliary outputs are inactive. To access the Memory iButton, the host A first
switches on the control output, thereby pulling the auxiliary line of the coupler at the B side low. This
tells host B that it is not allowed to activate the main output of coupler B. Now host A activates the main
output of coupler A and writes data to the Memory iButton. After the writing is complete, host A
deactivates the main output of coupler A and switches off the control output. Host B meanwhile has been
polling the logic level at the auxiliary line of coupler B and realizes that host A has finished the access.
Now host B follows the same procedure and accesses the memory to read the data, etc. The memory
iButton may be replaced by a MicroLAN network. The Silicon Label stores information telling the hosts
that these particular couplers access the same network and that the control and auxiliary outputs are crosscoupled for handshaking.
MicroLAN TRUNK WITH BRANCHES Figure 10
15 of 18
102199
DS2409
DUAL MASTER SYSTEM Figure 11
16 of 18
102199
DS2409
ABSOLUTE MAXIMUM RATINGS*
Voltage on Data to Ground
Operating Temperature
Storage Temperature
Soldering Temperature
-0.5V to +7.0V
-40°C to +85°C
-55°C to +125°C
260°C for 10 seconds
* This is a stress rating only and functional operation of the device at these or any other conditions above
those indicated in the operation sections of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods of time may affect reliability.
DC ELECTRICAL CHARACTERISTICS
PARAMETER
Logic 1 (1-Wire In)
Logic 0 (1-Wire In)
Output Logic Low @ 4 mA (1-Wire In)
Output Logic High (1-Wire In)
Input Load Current (1-Wire In)
Logic 1 (Main Out)
Logic 0 (Main Out)
Output Sink Current @ 0.4V (Main Out)
Logic 1 (Aux. Out)
Logic 0 (Aux. Out)
Output Sink Current @ 0.4V (Aux. Out)
Output Leakage (Control Output)
Current @ 0.4V (Control Output)
Operating Current
Quiescent Current
SYMBOL
VIH1
VIL1
VOL1
VOH1
IL1
VIHM
VILM
ISM
VIHA
VILA
ISA
ILOC
IOLC
IDD
IDDQ
(-40°C to +85°C, VDD = 5V ±10%)
MIN
2.2
-0.3
TYP
MAX
VDD
+0.8
0.4
VPUP
5
2.2
-0.3
+0.8
10
2.2
-0.3
+0.8
10
1
10
50
25
CAPACITANCE
PARAMETER
Capacitance 1-Wire In
Capacitance Main Out
Capacitance Aux. Out
NOTES
1
1
1
1, 3
4
1
1
1, 8
1
1
1
2
2
(tA = 25°C)
SYMBOL
CIN1
CINM
CINA
MIN
TYP
MAX
50
50
50
SYMBOL
ZMON
ZAON
RPU
MIN
TYP
10
15
1.5
MAX
20
30
RESISTANCES
PARAMETER
1-Wire In to Main ON Res.
1-Wire In to Aux. ON Res.
Main and Aux. Pullup Res.
UNITS
V
V
V
V
µA
V
V
mA
V
V
mA
µA
mA
µA
µA
UNITS
pF
pF
pF
NOTES
(-40°C to +85°C)
17 of 18
UNITS
?
?
k?
NOTES
102199
DS2409
AC ELECTRICAL CHARACTERISTICS
PARAMETER
Time Slot
Write 1 Low Time
Write 0 Low Time
Read Low Time
Read Data Valid
Release Time
Read Data Setup
Recovery Time
Reset Time High
Reset Time Low
Presence Detect High
Presence Detect Low
SYMBOL
tSLOT
tLOW1
tLOW0
tLOWR
tRDV
tRELEASE
tSU
tREC
tRSTH
tRSTL
tPDH
tPDL
(-40°C to +85°C, VDD = 5V ±10%)
MIN
60
1
60
1
0
1
480
480
15
60
TYP
MAX
120
15
120
15
exactly 15
15
45
1
960
60
240
UNITS
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
NOTES
6
5
7
NOTES:
1. All voltages are referenced to ground.
2. Measured with outputs open.
3. VPUP = external pullup voltage.
4. Input load is to ground.
5. An additional reset or communication sequence cannot begin until the reset high time has expired.
6. Read data setup time refers to the time the bus master must pull the I/O line low to read a bit. Data is
guaranteed to be valid within 1 µs of this falling edge.
7. The reset low time (tRSTL) should be restricted to a maximum of 960 µs, to allow interrupt signaling,
otherwise, it could mask or conceal interrupt pulses. The DS2409 may perform a power-on reset cycle
and deactivate both 1-Wire outputs if the 1-Wire input is low for minimum 8 ms. A low time of 12 ms
or more will always cause a power-on reset cycle.
8. The main output has a slew rate controlled output. The indicated current is a DC value. The sink
current typically reaches 80% of its DC value 1 µs after turning on the transistor.
18 of 18
102199
Similar pages