Series AM6CW-NZ 6 Watt | DC-DC Converter Picture coming soon FEATURES: Wide 4:1 Input Voltage Range High efficiency up to 85% 1500 VDC Isolation Low ripple & noise Operating Temperature -40ºC to +85ºC Output Over Voltage protection Continuous Short Circuit Protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) AM6CW-11005S-NZ AM6CW-11012S-NZ AM6CW-11015S-NZ AM6CW-11024S-NZ 40-160 40-160 40-160 40-160 5 12 15 24 1200 500 400 250 1500 1500 1500 1500 1000 100 100 47 81 83 85 85 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Voltage range Filter Absolute Maximum Rating (100ms) No Load Input Current Input reflected current 110 40-160 Pi Maximum Units VDC 110 180 VDC mA mA Maximum Units >1000 VDC MOhm pF 2 20 Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions Typical 60 sec, <1mA 500VDC 1500 1000 Output Specifications Parameters Voltage accuracy Over voltage protection Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple Noise Transient recovery time Transient recovery deviation Conditions Typical Maximum ±2 110-140 Continuous Auto-Recovery ±0.5 ±1 Full load, LL to HL 5% to 100% load 100% load % % of Vo ±0.03 25 100 25% load step change 25% load step change Units 1 ±5 % of Vin % %/oC mV p-p mV p-p mS % General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling www.aimtec.com F 051e R13 Conditions Typical 100% load Derating above 71°C 300 Maximum Units 100 KHz oC oC oC -40 to +85 -55 to +125 Free air convection Tel: +1 514 620 2722 1 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM6CW-NZ 6 Watt | DC-DC Converter General Specifications (continued) Parameters Conditions Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Vibrations Typical Maximum Units 95 % RH Aluminum Alloy 14 1 x 1 x 0.46 inches 25.40 x 25.40 x 11.70 mm o >1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C) 1.5mm from case for 10 sec 300 5-150Hz, Displacement: 7.5mm, Acceleration: 2g g oC Safety Specifications Parameters Meets EN60950-1 EN 55022, class B (with the recommended EMC circuit) Standards Pin Out Specifications Pin 1 2 3 4 Single -Vin +Vin +Vout -Vout Dimensions Bottom View 20.32 (0.80) 2.54 (0.10) Top View 25.40 (1.00) 4 3 20.32 (0.80) 25.40 (1.00) +V Output -V Output +V -V Input Input 2.54 (0.10) 1 Side View 10.16 (0.40) 2 5.08 (0.20) Printed Face 9.90 (0.39) Notes: All dimensions are typical in millimeters (inches). Case Tolerance ±0.25 (±0.01) Pin diameter tolerance ±0.1 (±0.004) Pin height tolerance ±0.5 (±0.02) 2.54 (0.10) www.aimtec.com F 051e R13 1.00 (0.39) Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM6CW-NZ 6 Watt | DC-DC Converter Derating Free Air Convection 71º C Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C Recommended EMC Circuit Y1 L1 10mH 1nF/2KV L1 10mH +Vo +Vin CX 0.68uF CX 0.68uF CX 0.68uF AM6CW‐NZ ‐Vin ‐Vo Y2 1nF/2KV NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R13 Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only