N D ES IG EW M M EN D RoHS lead free solder Certified to efficiency 80plus platinum Wide input voltage range 90-264 VAC Two outputs (one high current output) Low conducted and radiated EMI (EN 55022 class B) Safety approved to the latest editions of the following standards: CSA/UL60950-1, EN60950-1 and IEC60950-1 High density design 4” x 1.58” x 8.5” cassette Highly-efficient topology I2C interface Overtemperature, output overvoltage, and output overcurrent protection Supervisory signaling Included ORing FET for true redundant operation Model meet international safety standards and display the CE Mark for the low Voltage Directive. Telecommunication Equipment O T RE C O ED FO R N The FCP400-12G is highly-efficient AC-DC power supply, with one high current output and an additional standby output, which can be used in a wide range of applications. Active current share along with internal ORing FET allow the FCP400's to be also used in redundant, hot-swap applications. N North America +1-866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353 61 225 977 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00141_AC FCP400-12G Model Input Voltage VAC FCP400-12G* 90-264 Output 1 Output 2 Vo nom Io max Vo nom Io max VDC 12 ADC 33.3 VDC 12 ADC 0.7 Rated Power W 408 D ES IG N * Suffix “G” added to the part number means the product is RoHS compliant for all 6 substances Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-term reliability, and cause permanent damage to the converter. Input Voltage Operating Temperature MAX 264 300 UNITS VAC VAC 0 55 °C -40 85 °C FO R Storage Temperature MIN EW CONDITIONS / DESCRIPTION Continuous Transient, 60 ms Ambient Vi min-Vi max, Io nom, cooling by internal fan Non-operational N PARAMETER All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. CONDITIONS / DESCRIPTION Input Voltage Ramping up Turn-Off Input Voltage Ramping down EN D Turn-On Input Voltage ED PARAMETER Input Frequency 115/230 VAC Power Factor Vi nom, Io nom Efficiency Vi = 230 VAC, Io nom NOM MAX UNITS 90 115/230 264 VAC 70 - 90 VAC 70 - 90 VAC 47 50/60 63 Hz 20/27 A 0.96 90 % M M Inrush Current Limitation MIN RE C PARAMETER O All specifications apply over specified input voltage, output load, and temperature range unless otherwise noted. O T Output Voltage Setpoint Accuracy Output Current V1 Output Current V2 Static Line Regulation V1 Static Load Regulation V1 (Droop Characteristic) Hold-Up Time CONDITIONS / DESCRIPTION MIN Vi = 230 VAC, Io1 @ 16.6 ADC, TC = 25 °C Vi min-Vi max, Vi nom, 0-100% Io nom -0.01 0 0 -0.06 Vi min-Vi max, Vi nom, 0-100% Io nom -0.1 Starting at Vi = 230 VAC, Po nom 20 NOM MAX UNITS VDC 33.3 0.7 0.01 33.3 0.7 0.06 ADC 0.1 VDC VDC ms Start-Up Time Vi nom, Io nom 1.5 VDC s s Output Voltage Ripple and Noise Vi nom, Io nom, 20 MHz bandwidth 120 mVpp N Dynamic Load Regulation Load change 5A to 16A, 16A to 27A and back voltage deviation recovery time -0.24 0.24 400 +1.866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00141_AC FCP400-12G All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS / DESCRIPTION Input Fuse Not user accessible Input Transient Protection Overvoltage Protection With varistor No-load and short circuit proof short circuit proof overload (latch style) Latch type – disable output V1 Overtemperature Protection Automatic power shutdown at TA = 62 °C NOM MAX UNITS 8A T % Io nom % Vo nom N 110 115 130 130 D ES IG Output MIN All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. CONDITIONS / DESCRIPTION I2C Digital Bus Reports information and monitors alarm functions PS Seated Signal Contact closure to GND TTL compatible signal, open collector. Power supply enabled at Low or TTL "0" (e.g. by connecting of pin 22 to 0V or GND) Supervisory AC input voltage; N PS Remote Shutdown EW PARAMETER AC Fail Warning (I2C & OC)* DC fail (I2C & OC)* R Supervisory under- and overvoltage pre-ORing FET of V1 Indicates if unit is operating normally or in overtemperature, Pre-warning time >10 ms Indicates if fan speed is below 80% of the currently required level Active current share for V1 Droop load characteristic for V2 LEDs: DC OK (green), AC OK (green) FO Temperature Warning (I2C & OC)* Fan Fail (I2C & OC)* Current Share ED Status Indication EN D * Signal provided by I2C interface or by open collector (OC) All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. CONDITIONS / DESCRIPTION Operating Humidity Relative humidity, non-condensing Storage Humidity Relative humidity, non-condensing M M PARAMETER RE C Sinusoidal Vibration NOM UNITS 10 90 % 5 95 % 30 gn 15 2 4 mil gn gn kh 300 T MTBF IEC/EN 60068-2-27, 11 ms IEC/EN 60068-2-6 2-8 Hz 8-200 Hz 200-500 Hz MIL-HDBK-217F Notice 2, GB, 25 °C MAX O Shock MIN N O The electric strength test is performed in the factory as routine test in accordance with EN50514, IEC/EN 60950, and UL 1950 and should not be repeated in the field. Bel Power Solutions will not honor any warranty claims resulting from electric strength field tests. PARAMETER Insulation Safety Rating Electric Strength Test Voltage CONDITIONS / DESCRIPTION Input/Case Input/Output Output/Case Input/Case Input/Output Output/Case MIN 1.5 3.0 0.5 NOM Basic Reinforced Functional MAX UNITS kVAC kVAC kVDC +1.866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00141_AC FCP400-12G All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. DESCRIPTION Electrostatic Discharge IEC/EN 61000-4-2, level 4 (contact/air) 8/15 kV, Criterion B CRITERION Electromagnetic Field IEC/EN 61000-4-3, level 3 10 V/m, Criterion A Electr. Fast Transients / Burst IEC/EN 61000-4-4, level 3 (direct/capacitive) 2/1 kV, Criterion B Surge IEC/EN 61000-4-5, level 3 (L/L, L/C) Voltage Dips and Interruptions IEC/EN 61000-4-11 RF Conducted Immunity IEC/EN 61000-4-6 Emissions Radiated/Conducted CISPR 22/EN 55022/EN 61204 Harmonics IEC/EN 61000-3-2 Voltage Fluctuation and Flicker IEC/EN 61000-3-3 N PARAMETER D ES IG 1/2 kV, Criterion B <20 ms Criterion A >20 ms Criterion B 10 VAC, AM 80%, 1 kHz, Criterion A Class A / Class B Class B EW Pass N All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. CONDITIONS / DESCRIPTION 18 fan speed levels depending on inlet temperature, AC voltage and load. Fan speed and temperature information available on I2C digital bus. If unit is operating: 5 to 11V is provided at pin 3. If unit is NOT operating, pin 3 is input from a parallel connected unit for µC supply. R PARAMETER FO Fan speed control ED µC supply voltage in-/output (Pin 10) EN D EFFICIENCY VS. OUTPUT LOAD 96 94 M 92 M 90 88 O 86 RE C 84 82 80 N O T 0 5 10 15 20 Vi = 115Vac 25 30 35 Vi = 230Vac Figure 1 - Efficiency vs. Output Load PARAMETER CONDITIONS / DESCRIPTION Mechanical Dimensions (H x W x D) 4” (101.6 mm) x 1.58” (40.1 mm) x 8.5” (215.9 mm) Weight 2.866 lb (1.3 kg) +1.866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00141_AC FCP400-12G 71.2 2.803 17.34 .683 15.29 .602 108.28 4.263 D ES IG N 20.24 .797 13.1 .514 113.92 ±0.5 4.485 ±.020 Figure 2 – Mechanical Drawing (Front View) MOLEX CONNECTOR M EN D 101.6 ±0,5 4.000 ±.020 ED FO R 1.6 ±0.3 .063 ±.012 N 230.2 9.062 216.3 ±0,5 8.515 ±.020 EW Figure 3 – Mechanical Drawing (Rear View) M HANDLE MAIN LABEL Figure 4 – Mechanical Drawing (Top View) EMI CLIPS AIRFLOW DIRECTION (REAR TO FRONT) 13.3 40.13 ±0,5 1.580 ±.020 N O T 45° RE C O 19 ±0.5 .748 ±.020 9.1 .358 Figure 5 – Mechanical Drawing (Side View) +1.866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00141_AC D ES IG N FCP400-12G Figure 6 – Molex Connector (39-00-0046) PIN LOCATION 12 V Output 4,5,6,16,17,18 12 V Output RTN 1,2,3,13,14,15 11 12 Address Input Line A0 21 Address Input Line A1 20 5 to 11 V 10 FAN OK 12 V Standby SCL AO A1 µC supply voltage bus FAN_FAIL 22 PS_RSD_H 7 Vo2 RTN / Logic Ground / 5 to 11 V RTN 19 Vo2 8 ACS N O T RE C O M M Active Current share SDA 24 EN D PS Remote Shut Down 12 V Standby RTN N ED Serial Data Line Serial Clock Line PS_FAIL PS_PRSNT_L R 9 23 Vo1 Vo1 RTN FO AC-fail, DC-fail, Temp.-fail Power Supply Present Signal REFERENCE NAME EW OUTPUT CONNECTOR DESCRIPTION NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. +1.866.513.2839 [email protected] © 2015 Bel Power Solutions, Inc. BCD.00141_AC