A1500RU Series 4:1 Input Range, 15W Single & Dual Output DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 15W Output Power • 4:1 Input Voltage Range • Compact DIP Case • 1,600 VDC I/O Isolation • Meets EN 55022 “A” • Single & Dual Outputs • 37.5 W/IN3 Power Density • Industry Standard Pin-Out MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Input Parameter Conditions Input Voltage Range Input Filter Input Reflected Ripple Current Output Parameter Output Voltage Accuracy Line Regulation, VIN = Min to Max Load Regulation, IOUT = 0% to 100% Cross Regulation, Dual Output Ripple & Noise (20 MHz) Output Power Protection Transient Recovery Time, See Note 3 Transient Response Deviation Temperature Coefficient Output Short Circuit Protection General Parameter Isolation Voltage (Input/Output) Isolation Voltage (Case/Input, Output) Isolation Resistance Isolation Capacitance Switching Frequency EMI Characteristics Parameter Radiated Emissions Conducted Emissions ESD RS EFT, See Note 4 Surge, See Note 4 CS PFMF Environmental Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Reliability Specifications Parameter MTBF Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Min. Typ. Max. 24 VDC Input 9.0 24.0 36.0 48 VDC Input 18.0 48.0 75.0 (Pi) Filter (Meets EN 55022 Class “A”) 20.0 Conditions Min. Typ. ±1.0 Single Output Dual Output Single Output Dual Output See Note 1 See Note 2 Max. ±0.2 ±0.5 ±0.5 ±1.0 ±5.0 60 150 250 25% Load Step Change ±3.0 ±0.02 Continuous (Autorecovery) Conditions 3 Seconds 3 Seconds 500 VDC 100 kHz/1V Min. 1,600 1,600 1,000 Typ. 2,000 330 Standard mA P - P Units % % % % mV P - P % IOUT µSec % %/ºC Units M⍀ pF kHz Level Class A Class A Criteria B Criteria A Criteria B Criteria B Criteria A Criteria A EN 55022 EN 55022 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 Ambient Case VDC VDC 250 Conditions Max. Units Min. -40 Typ. -40 Free Air Convection RH, Non-condensing 95 Max. +85 +105 +125 Units ºC ºC ºC % 1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm) Metal with Non-Conductive Base (UL94V-0) 0.705 Oz (20g) Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. 410 Typ. Max. Units kHours Conditions 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec Min. -0.7 -0.7 Typ. Max. 50.0 100.0 260 Units Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC ºC www.micropowerdirect.com Model Selection Guide Input Model Number Output Voltage (VDC) Current (mA) Nominal Range 24 24 24 24 24 24 24 48 48 48 48 48 48 48 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 A1501RU A1502RU A1503RU A1504RU A1505RU A1506RU A1507RU A1511RU A1512RU A1513RU A1514RU A1515RU A1516RU A1517RU Full-Load No-Load 647 732 710 710 744 718 710 327 370 355 359 372 359 355 10 10 10 10 10 10 10 5 5 5 5 5 5 5 Voltage Current Current (VDC) (mA, Max) (mA, Min) 3.3 5.1 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.1 12.0 15.0 ±5.0 ±12.0 ±15.0 4,000 3,000 1,250 1,000 ±1,500 ±625 ±500 4,000 3,000 1,250 1,000 ±1,500 ±625 ±500 Notes: 1. When measuring cross regulation, the load on one output is varied from 25% to 100% while the other output is held at 100%. 2. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor be placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. 3. Transient recovery is measured to within a 1% error band for a load step change of 75% to 50% to 25%. 4. To meet the requirements of EN 61000-4-4 and EN 61000-4-5, an external filter capacitor is required. It is recommended that a 680 µF/100V (or two 330 µF/100V capacitors connected in parallel) be used. 5. Operation at no-load will not damage these units. However, they may not meet all specifications. 6. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+VOUT) and negative (-VOUT) outputs and float the output common. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Min Supply On Supply Off Standby Input Current Control Common 3.0 0.0 0.0 0.0 0.0 0.0 ±0.0 ±0.0 ±0.0 0.0 0.0 0.0 0.0 ±0.0 ±0.0 ±0.0 (VDC) 3.9 6.2 15.0 18.0 ±6.2 ±15.0 ±18.0 3.9 6.2 15.0 18.0 ±6.2 ±15.0 ±18.0 (µF Max) 4,700 3,300 600 400 ±1,500 ±288 ±200 4,700 3,300 600 400 ±1,500 ±288 ±200 87 89 90 90 86 89 90 86 88 90 89 86 89 90 3,000 3,000 3,000 3,000 3,000 3,000 3,000 1,500 1,500 1,500 1,500 1,500 1,500 1,500 Derating Curve Mechanical Dimensions Remote ON/OFF Parameter Over Max Rating Voltage Capacitive Efficiency Fuse Slow-Blow Protection Load (%, Typ) (mA) Max Units VDC VDC 12 or Open 1.2 5 mA Typical Referenced to Neg. Input (pin 2,3) Pin Connections Pin Single 1 Remote On/Off 2 -VIN 3 -VIN 9 No Pin 11 NC 14 +VOUT 16 -VOUT 22 +VIN 23 +VIN NC: No Connection Dual Remote On/Off -VIN -VIN Common -VOUT +VOUT Common +VIN +VIN Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]