Panasonic ADE223 Compliant with european standards european standards power relay Datasheet

DE (ADE)
VDE
Compliant with
European standards
1a1b 10A/8A polarized
power relays
RoHS compliant
DE RELAYS (ADE)
FEATURES
TYPICAL APPLICATIONS
1. Conforms to European safety
standard (VDE0700 and VDE0631).
Insulating distance between coil and
contacts:
Clearance Min. 8mm .315 inch
Creepage Min. 8mm .315 inch
2. Low operating power
Nominal operating power at 200 mW
(Single side stable, 2 coil latching)
3. Compact body saves space
Size: 12.5(W) × 25(L) × 12.5(H) mm
.492(W) × .984(L) × .492(H) inch
4. Conforms to the various safety
standards
UL, CSA and VDE approved
1. Temperature controller
2. Automatic meter reading
3. OA equipment
4. FA equipment
ORDERING INFORMATION
ADE
DE relay
Contact arrangement
1: 1 Form A
2: 2 Form A
3: 1 Form A 1 Form B
Operating function
0: Single side stable
2: 2 coil latching
Nominal coil voltage (V DC)
3: 12V, 4: 24V, 9: 5V
Notes: 1. Certified by UL, CSA and VDE
2. This product is manufactured by lot after an order is received.
TYPES
Contact arrangement
1 Form A
1 Form A 1 Form B
2 Form A
Nominal coil voltage
5V DC
12V DC
24V DC
5V DC
12V DC
24V DC
5V DC
12V DC
24V DC
Single side stable type
Part No.
ADE109
ADE103
ADE104
ADE309
ADE303
ADE304
ADE209
ADE203
ADE204
2 coil latching type
Part No.
ADE129
ADE123
ADE124
ADE329
ADE323
ADE324
ADE229
ADE223
ADE224
Standard packing: Tube package: 20 pcs.; Case: 500 pcs.
Note: This product is manufactured by lot after an order is received.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB175E 201202-T
DE (ADE)
RATING
1. Coil data
1) Single side stable type
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
5V DC
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
12V DC
24V DC
Nominal operating
current
[±10%] (at 20°C 68°F)
40 mA
16.6mA
8.3mA
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
720Ω
2,880Ω
200mW
130%V of
nominal voltage
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
125Ω
2) 2 coil latching type
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
5V DC
70%V or less of
nominal voltage
(Initial)
70%V or less of
nominal voltage
(Initial)
12V DC
24V DC
Nominal operating
current
[±10%] (at 20°C 68°F)
Set coil
Reset coil
40 mA
40 mA
16.6mA
8.3mA
16.6mA
8.3mA
Set coil
125Ω
Reset coil
125Ω
Set coil
Reset coil
720Ω
2,880Ω
720Ω
2,880Ω
200mW
200mW
Max. applied voltage
(at 20°C 68°F)
130%V of
nominal voltage
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity*1
Insulation resistance (Initial)
Between open contacts
Between contact sets
Between contact and coil
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Temperature rise (coil) (at 70°C 158°F)
Breakdown voltage
(Initial)
Electrical
characteristics
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Shock resistance
Mechanical
characteristics
Expected life
Conditions
Electrical
Conditions for operation, transport and storage*3
Max. operating speed
Unit weight
Specifications
1 Form A 1 Form B
2 Form A
Max. 30 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
10A 250V AC, 10A 30V DC
8A 250V AC, 8A 30V DC
2,500VA, 300W
2,000VA, 240W
250V AC, 30V DC
250V AC, 30V DC
10A
8A
200mW
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1 Form A
—
1,000 Vrms for 1 min. (Detection current: 10 mA)
4,000 Vrms for 1 min. (Detection current: 10 mA)
5,000 Vrms for 1 min. (Detection current: 10 mA)
12,000 V
Max. 50°C 122°F (By resistive method)
Max. 10 ms [Max. 10 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 5 ms [Max. 10 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 2 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 3 mm
Min. 107 (at 300 times/min.)
Min. 105 (resistive load,
at 20 times/min., at AC nominal
Min. 105
switching capacity)
(resistive load, at 20 times/min., at nominal switching capacity)
Min. 5×104 (resistive load,
at 20 times/min., at DC nominal
switching capacity)
Ambient temperature: –40°C to +70°C –40°F to +158°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)
Approx. 7 g .25 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
ASCTB175E 201202-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
DE (ADE)
REFERENCE DATA
1.-(1) Maximum switching power (1 Form A)
1.-(2) Maximum switching power
(1 Form A 1 Form B, 2 Form A)
100
AC resistive load
10
DC resistive load
1
0.1
100
50
250 V AC resistive load
30 V DC resistive load
AC resistive load
Life, ×104
Contact current, A
Contact current, A
100
2.-(1) Life curve (1 Form A)
10
10
DC resistive load
1
1
10
0.1
100
1000
Contact voltage, V
2.-(2) Life curve (1 Form A 1 Form B)
1
10
1000
100
Contact voltage, V
2.-(3) Life curve (2 Form A)
0
1
2
3
4 5 6 7 8
Contact current, A
9
10
3.-(1) Coil temperature rise (1 Form A)
Tested sample: ADE109
Quantity: n=6
Ambient temperature: 25°C to 70°C 77°F to 158°F
50
50
250 V AC resistive load
30 V DC resistive load
50
Life, ×104
250 V AC resistive load
10
10
Temperature rise, °C
100
Life, ×104
100
25°C 77°F
70°C 158°F
40
10A
0A
10A
0A
30
20
30 V DC resistive load
10
0
1
2
3
4 5 6 7 8
Contact current, A
9
0
10
1
2
3
4 5 6 7 8
Contact current, A
9
0
10
70
80
90
100
110 120
Coil applied voltage, %V
130
3.-(2) Coil temperature rise (1 Form A 1 Form B)
3.-(3) Coil temperature rise (2 Form A)
4.-(1) Operate/release time (1 Form A)
Tested sample: ADE309
Quantity: n=6
Ambient temperature: 25°C to 70°C 77°F to 158°F
Tested sample: ADE209
Quantity: n=6
Ambient temperature: 25°C to 70°C 77°F to 158°F
Tested sample: ADE109
Quantity: n=5
40
8A
0A
8A
30
0A
20
10
9
25°C 77°F
70°C 158°F
8A
40
8A
0A
0A
30
20
Operate/release time, ms
50
25°C 77°F
70°C 158°F
Temperature rise, °C
Temperature rise, °C
50
8
Operate time
7
6
Max.
x
Min.
Max.
x
Min.
5
4
3
2
10
Release time
(With diode)
Max.
x
Min.
1
0
70
80
0
90
100
110 120 130
Coil applied voltage, %V
70
80
90
100
110 120 130
Coil applied voltage, %V
4.-(2) Operate/release time (1 Form A 1 Form B)
4.-(3) Operate/release time (2 Form A)
Tested sample: ADE309, Quantity: n=5
Tested sample: ADE209, Quantity: n=5
Release time
0
70
80
90
100
110
120
130
Coil applied voltage, %V
5.-(1) Ambient temperature characteristics
(1 Form A)
Tested sample: ADE109, Ambient temperature:
–40°C to 80°C –40°F to 176°F, Quantity: n=6
6
Max.
x
Min.
5
4
3
Max.
x
Min.
Max.
x
Min.
Operate time
2
7
Operate time
6
Max.
x Max.
Min.
x
Min.
5
4
3
Release time
70
80
90
100
110
120
130
Coil applied voltage, %V
Panasonic Corporation
0
–20
–4
Max.
x
Min.
1
0
–40
–40
Release time
(With diode)
2
1
Rate of change, V%
8
Release time
(With diode)
Operate/release time, ms
Operate/release time, ms
7
30
20
10
0
Drop-out
voltage
Pick-up
voltage
0
20 40
60
80
32
68 104 140 176
–10
Ambient
–20 temperature,°C °F
–30
Release time
70
80
90
100 110
120 130
Coil applied voltage, %V
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB175E 201202-T
DE (ADE)
Tested sample: ADE309, Ambient temperature:
–40°C to 80°C –40°F to 176°F, Quantity: n=6
Tested sample: ADE209, Ambient temperature:
–40°C to 80°C –40°F to 176°F, Quantity: n=6
–40
–40
–20
–4
Rate of change, V%
5.-(3) Ambient temperature characteristics
(2 Form A)
Rate of change, V%
5.-(2) Ambient temperature characteristics
(1 Form A 1 Form B)
30
Drop-out
20 voltage
10
0
Pick-up
voltage
0
20 40
60
80
32
68 104 140 176
–10
Ambient
temperature,°C °F
–20
–40
–40
–20
–4
0
32
–10
–20
–30
30
Drop-out
20 voltage
Pick-up
voltage
10
0
20 40
60
80
68 104 140 176
Ambient
temperature,°C °F
–30
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
CAD Data
PC board pattern (Bottom view)
Single side stable
Single side stable
25.0
.984
12.5
.492
15.24
.600
12.0
.472
7.62
.300
0.8
.032
1.0
.039
2.44
.096
12.70
.500
8-1.2 dia.
8-.047 dia.
7.62
.300
7.62
.300
0.4
.016
7.62
.300
Tolerance : ±0.1 ±.004
Schematic (Bottom view)
2 coil latching type
12.5
.492
12.0
.472
0.5
.020
1
3
4
8
6
5
7.62
.300
0.8
.032
1.0
.039
2.44
.096
0.4
.016
7.62
.300
Tolerance: ±0.3 ±.012
3
4
1
3
4
8
6
5
8
6
5
(Deenergized condition)
(1 Form A)
2coil latching type
(1 Form A 1 Form B)
1
2
3
4
1
8
7
6
5
8
(5,6: dummy terminal)
(2 Form A)
1
(5,6: dummy terminal)
3.5
.138
0.8
.032
0.5 dia.
.020 dia.
12.70
.500
Single side stable
(1 Form A 1 Form B)
(1 Form A)
25.0
.984
2.54
.100
2.54
.100
3.5
.138
0.8
.032
15.24
.600
0.5 dia.
.020 dia.
6-1.2 dia.
6-.047 dia.
7.62
.300
0.5
.020
0.5 dia.
.020 dia.
7.62
.300
2 coil latching type
(2 Form A)
2
3
4
1
2
3
4
7
6
5
8
7
6
5
(Reset condition)
SAFETY STANDARDS
Item
1 Form A
1 Form A
1 Form B
2 Form A
File No.
E120782
E120782
E120782
UL/C-UL (Recognized)
Contact rating
PILOT DUTY B300
R300
PILOT DUTY B300
R300
PILOT DUTY B300
R300
File No.
LR85932
LR85932
LR85932
CSA (Certified)
Contact rating
PILOT DUTY B300
R300
PILOT DUTY B300
R300
PILOT DUTY B300
R300
File No.
115944
VDE (Certified)
Contact rating
8A 250V AC (cosφ =1.0)
115944
8A 250V AC (cosφ =1.0)
115944
8A 250V AC (cosφ =1.0)
For Cautions for Use.
ASCTB175E 201202-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
Similar pages