Aeroflex ACT4464 Act 4458 / 4464 single supply transceivers for mil-std-1553/1760 Datasheet

ACT 4458 / 4464
SINGLE SUPPLY TRANSCEIVERS
FOR MIL-STD-1553/1760
Features
• Single 5 Volt Supply Operation
• Low Power Dissipation
• Small Size & Light Weight
• Dual Transceivers Save Space & Cost
• Outstanding MIL-STD-1553 performance
• Processed and Screened to Mil-STD-883 Specs
• Radiation Hard Dielectric Isolation Monolithic construction
for Severe Environments
• Superior High Frequency Line Transient and Input Ripple
Rejection
• Input and Output TTL Compatible Design
• DESC SMD# 5962-92061
CIRCUIT TECHNOLOGY
www.aeroflex.com/act1.htm
General Description:
The Aeroflex Circuit Technology
ACT4458 / 4464 series are next
generation monolithic transceiver
designs
which
provides
full
compliance with MIL-STD-1553A/B
and 1760 requirements in the
smallest packages with low power
consumption and single power supply
operation.
The ACT4458 / 4464 series
performs the front-end analog
function of inputting and outputting
data through a transformer to the
MIL-STD-1553 data bus.
Design of these transceivers
reflects particular attention to active
filter performance. This results in low
bit and word error rate with superior
waveform purity and minimal zero
crossover
distortion.
Efficient
transmitter electrical and thermal
design provides low internal power
dissipation and heat rise at high as
well as low duty cycles.
Case Style
ACT 4458FP
Actual Size
TX DATA OUT
TX DATA IN
DRIVER
TX DATA IN
ACTIVE
FILTER
OUTPUT
STAGE
REFERENCE
COMP.
TX DATA OUT
TX INHIBIT
+5 V
RX DATA OUT
+5V RTN
RX DATA IN
RX DATA IN
Each channel of the dual
transceiver is completely separate
from the other and fully independent.
This includes power leads as well as
signal lines. Hence, each channel
may be connected to a different data
bus with no interaction.
Transmitter:
INPUT
AMPLIFIER
ACTIVE
FILTER
RX DATA OUT
COMP.
STROBE
Block Diagram (without Transformer)
The Transmitter section accepts
bi-phase TTL data at the input and
when coupled to the data bus with a
1:2.5 ratio transformer, isolated on
the data bus side with two 52.5 Ohm
fault isolation resistors, and loaded by
eroflex Circuit Technology – Data Bus Modules For The Future © SCD4458 REV A 1/29/98
two 70 Ohm terminations, the data
bus signal is typically 7.5 volts P-P
at A-A' (See Figure 5). When both
DATA and DATA inputs are held low
or high, the transmitter output
becomes a high impedance and is
“removed” from the line. In addition,
an
overriding
“INHIBIT
input
provides for the removal of the
transmitter output from the line. A
logic “1” applied to the “INHIBIT”
takes priority over the condition of
the data inputs and disables the
transmitter. (See Transmitter Logic
Waveform,
Figure
1.)
The
Transmitter may be safely operated
for an indefinite period with the bus
(point A-A') short circuited at 100%
duty cycle.
Receiver:
The Receiver section accepts
bi-phase differential data at the input
and produces two TTL signals at the
output. The outputs are DATA and
DATA, and represent positive and
negative excursions of the input
beyond
a
pre-determined
threshold.(See
Receiver
Logic
Waveform. Figure 2.)
detect data bus signals exceeding
1.20 Volts P-P and reject signals
less than 0.6 volts P-P when used
with a transformer. (See Figure 5
for transformer data and typical
connection.)
A low level at the Strobe input
inhibits the DATA
and DATA
outputs. If unused, a 2K pull-up to
+5 Volts is recommended
The pre-set internal thresholds will
Figure 1 — Transmitter Logic Waveforms Idealized*
DATA IN
DATA IN
INHIBIT
LINE TO LINE
OUTPUT
Note: DATA and DATA inputs must be complementary waveforms or 50% duty cycle average, with no delays between them,
and must be in the same state during off times (both high or low).
Figure 2 — Receiver Logic Waveforms Idealized*
LINE TO LINE
INPUT
STROBE
DATA OUT
DATA OUT
Note overlap
* See Figure 8 For Actual Waveforms
Aeroflex Circuit Technology
2
SCD4458 REV A 1/29/98 Plainview NY (516) 694-6700
Absolute Maximum Ratings
Operating case temperature
-55°C to +125°C
Storage case temperature
-65°C to +150°C
Power supply voltage
-0.3 V to +7.0 V
Logic input voltage
-0.3 V to +5.5 V
Receiver differential input
±10 V
Receiver input voltage (common mode)
±5 V
Driver peak output current
600 mA
Total package power dissipation over the full operating
case temperature rise
2 Watts
(Note: Normal operation conditions require one transceiver on and the
other off.)
Maximum junction to case temperature
10°C
Thermal resistance – junction to case
5°C/W
Electrical Characteristics — Driver Section
Input Characteristics, TX DATA in or TX DATA in (Notes 2 & 3 apply)
Parameter
Condition
Symbol
"0" Input Current
VIN = 0.4 V
"1" Input Current
VIN = 2.7 V
Typ
Max
Unit
IILD
-0.2
-0.4
mA
IIHD
1
40
µA
0.7
V
"0" Input Voltage
VILD
"1" Input Voltage
VIHD
Min
2.0
V
Inhibit Characteristics
"0" Input Current
VIN=0.4V
"1" Input Current
VIN=2.7V
IILI
IIHI
"0" Input Voltage
VILI
"1" Input Voltage
VIHI
mA
-0.2
-0.4
1.0
40
µA
0.7
V
V
2.0
Delay from TX inhibit, (0→1) to inhibited output
tDXOFF
250
350
nS
Delay from TX inhibit, (1→0) to active output
tDXON
150
250
nS
Differential output noise, inhibit mode
VNOI
2
10
mVP-P
Differential output impedance (inhibited)
Note 1
ZOI
Ω
2K
Output Characteristics
Differential output level
RL=35 Ω
Rise and fall times(10% to 90% of P-P output)
Output offset at point A-A' on Figure 5, 2.5µS
after midpoint crossing of the parity bit of the
last word of a 660µS message
VO
tr
RL=35 Ω
Delay from 50% point of TX DATA or TX DATA
input to zero crossing of differential signal
6
7.5
9
VP-P
100
200
300
nS
± 90
mV peak
250
nS
VOS
tDTX
120
Note 1. Power on or off, measured from 75KHz to 1MHz at point A-A' and transformer self impedance of 3KΩ
minimum
Aeroflex Circuit Technology
3
SCD4458 REV A 1/29/98 Plainview NY (516) 694-6700
Electrical Characteristics — Receiver Section
Parameter
Condition
Symbol
TXFMR
2.12:1
VIDR
Differential Receiver Input Voltage Range
(See Figure 5, point P–P')
Common Mode Rejection Ratio (Note 3)
CMRR
Min
Typ
Max
Unit
14
20
VP-P
45
dB
Strobe Characteristics (Logic "O" Inhibits Output)
"0" Input Current
VS=0.4 V
IIL
-0.2
-0.4
mA
"1" Input Current
VS=2.7V
IIH
1
+40
µA
0.7
V
"0" Input Voltage
VIL
"1" Input Voltage
VIH
Strobe Delay (Turn-on or Turn-off)
tSD
V
2.0
50
100
nS
1.10
V P-P
Threshold Characteristics (Sinewave Input)
Input Threshold Voltage (referred to the bus)
100KHz–1MHz
VTH
0.60
0.82
2.5
3.7
Output Characteristics – RX DATA and RX DATA
"1" State
IOH = -0.4 mA
VOH
"0" State
IOL = -4.0 mA
VOL
0.35
0.5
V
tDRX
340
500
nS
18
30
150
175
50% duty cycle
300
350
100% duty cycle
600
700
+5.00
+5.50
Delay, (average) from Differential Input Zero
Crossings to RX DATA and RX DATA Output
50% points
V
Power Data
Power Supply Currents – Per Channel
Transmitter Standby
25% duty cycle
Note 4
mA
ICC
Power Supply Voltage
VCC
Operating Power Supply Voltage Range
+4.75
V
Note 2: Vcc = 5 Volts ±0.1 V, bypassed by 2.2 µF (Tantalum recommended) Capacitor minimum. All measurements &
specifications apply over the temperature range of -55°C to +125°C (case temperature) unless otherwise
specified.
Note 3: When measured at point A-A’ with ± 10 Volt peak, line to ground, DC to 2MHz
Note 4: Typical power is measured with Vbus at point A-A’ = 7.5 VP-P
Aeroflex Circuit Technology
4
SCD4458 REV A 1/29/98 Plainview NY (516) 694-6700
Figure 3 – Transmitter (TX) Output Wave form
Figure 4 – Transmitter (TX) Output offset
LAST BIT
tf*
90%
Magnified View
6V P-P MIN
9V P-P MAX
0 Volts
OUTPUT OFFSET
*
OUTPUT OFFSET
*
0 volts
10%
2.5 µsec
tr*
*Offset measured at point A-A' in Figure 5
* Rise and fall times measured at point A-A' in Figure 5
Figure 5 – Typical direct transformer connection
70Ω
Figure 6 – Power Dissipation vs. Duty Cycle
(Total hybrid with one channel transmitting
and the other not powered)
70Ω
2000
N1:N2
TX DATA OUT
P
B
A
Center
Tap
TX DATA OUT
P'
POWER DISSIPATION
MILLIWATTS
1800
52.5Ω
N1:N3 for
Stub
Coupling
A'
B'
52.5Ω
1600
1400
1200
Maximum
1000
Typical
800
RX DATA IN
600
RX DATA IN
400
200
Transformer turns ratios:
N1:N2 = 1:2.5
N1:N3 = 1:1.77
Use Technitrol 1553-45 or equivalent
Aeroflex Circuit Technology
0
0
10
20
30
40
50
60
70
80
90 100
DUTY CYCLE – PERCENT
Note:Vcc=5 Volts,Transformer ratio 1:2.5, Vbus (pt A-A') at 7.5 Volts P-P
5
SCD4458 REV A 1/29/98 Plainview NY (516) 694-6700
Figure 8 ACTUAL HYBRID WAVEFORMS* — 25°C TYPICAL
START OF WORD – 33 WORD TRANSMISSION
TX DATA IN
CH 2
BUS OUT
Point A–A'
See Figure 5
CH 1
RX DATA OUT
CH 3
RX DATA OUT
CH 4
END OF WORD – 33 WORD TRANSMISSION
TX DATA IN
CH 2
BUS OUT
Point A–A'
See Figure 5
CH 1
RX DATA OUT
CH 3
RX DATA OUT
CH 4
* Oscilloscope used is a TEK TDS540 with Probe 6139A.
Aeroflex Circuit Technology
6
SCD4458 REV A 1/29/98 Plainview NY (516) 694-6700
Figure 7 – Pin Numbers & Functions
ACT4458/4464
Pin #
Aeroflex Circuit Technology
Function
Channel
1
TX DATA OUT/RX DATA IN
A
2
TX DATA OUT/RX DATA IN
A
3
GROUND 1
A
4
RX DATA OUT
A
5
STROBE
A
6
RX DATA OUT
A
7
TX DATA OUT/RX DATA IN
B
8
TX DATA OUT/RX DATA IN
B
9
GROUND 1
B
10
RX DATA OUT
B
11
STROBE
B
12
RX DATA OUT
B
13
GROUND 2
B
14
+5V
B
15
GROUND 3
B
16
INHIBIT
B
17
TX DATA IN
B
18
TX DATA IN
B
19
GROUND 2
A
20
+5V
A
21
GROUND 3
A
22
INHIBIT
A
23
TX DATA IN
A
24
TX DATA IN
A
7
SCD4458 REV A 1/29/98 Plainview NY (516) 694-6700
CIRCUIT TECHNOLOGY
Configurations and Ordering Information
Model No.
DESC No.
Receiver Data level
Case
Configuration
ACT 4458
5962-92061-07
Normally Low Rx
Flat Package
Dual
ACT 4464
5962-92061-08
Normally High Rx
Flat Package
Dual
Model ACT4458/4464 Flat Package
PIN 1
0.596
MAX
0.808
MAX
0.410
MIN
0.050
± 0.005
0.550
11 Equal Spaces
at 0.050
Noncumulative
0.018
MAX
0.010
± 0.003
0.095
MAX
0.056
MAX
Notes
1. Dimensions shown are in inches
2. Pins are equally spaced at 0.100±0.002 tolerance,
non-cumulative, each row
Telephone: (516) 694-6700
FAX:
(516) 694-6715
Toll Free Inquiries: 1-(800)THE-1553
Aeroflex Circuit Technology
35 South Service Road
Plainview New York 11830
Specifications subject to change without notice.
Aeroflex Circuit Technology
8
SCD4458 REV A 1/29/98 Plainview NY (516) 694-6700
Similar pages