AC-DC Converter DIP-Package ASD-5 Series, 5Watt FEATURES: Universal AC input/ Full range Typical Efficiency 75% Short circuit, over current protections Board in-line type installation High voltage isolation 4000Vac 100% burn-in test 3 year warranty Output voltage (Vdc) Output current (mA) Efficiency Typ. ASD5-3 3.3 1000 64% ASD5-5 5 1000 69% 9 550 73% 12 420 75% 15 330 76% 24 210 78% Model ASD5-9 ASD5-12 Input voltage (Vac) 85-264 ASD5-15 ASD5-24 Note: other input and output models may available on request. ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin --- 85 -- 264 Vac Input frequency Fline --- 47 -- 63 Hz Full load, Vin =115Vac -- 90 -- mA Full load, Vin =230Vac -- 40 -- mA Iinrush Cold start, Vin =230Vac -- 30 -- A η Full voltage, full load -- 75 -- % Ileakage Vin =230Vac -- -- 1 mA Input current Inrush current Efficiency Leakage current www.pairuigroup.com Iin Page: 1 / 4 Date: 11/09/2015 *Subject to change without notice AC-DC Converter DIP-Package ASD-5 Series, 5Watt ELECTRICAL Output Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Vout Vin=100-240Vac -- 2 -- % Line regulation Vout-line Vin from 100Vac to 240Vac -- 1 -- % Load regulation Vout-load 20%-100% load -- 1 -- % 50 -- ms -- Full load, Vin =115Vac -- Set-up rise time Full load, Vin =230Vac -- 20 -- ms Full load, Vin =115Vac -- 15 -- ms Full load, Vin =230Vac -- 40 -- ms --- -- 50 -- mV Output voltage accuracy Hold-up time Ripple -- Vripple Protection Over current Hiccup mode, it will auto-recovery after fault condition is removed Short circuit Hiccup mode, it will auto-recovery after fault condition is removed Environment Storage Ambient operating temperature Operating relative humidity MTBF Tstorage Humidity: 5% RH to 95% RH Startup at rated voltage Ta (Please refer to derating curve) Ha Non condensing TMTBF Full load, 230Vac input, ℃ 25 ambient temperature Dimension(LxWxH) -40 -- +85 ℃ -40 -- +70 ℃ 10 -- 90 % -- -- 200 kHrs 50.8 x 25.4 x 15.3mm Safety Safety standards UL1012, EN60950, UL60950 Withstand voltage I/P-O/P:4KVac 2mA/1min Insulation Resistance I/P-O/P: EMI / RFI conducted EN55011, EN55022 (CISPR22) >100M Ohms/500VDC/25℃/70%RH ℃ Notes: 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and input nominal voltage; 2. Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. www.pairuigroup.com Page: 2 / 4 Date: 11/09/2015 *Subject to change without notice AC-DC Converter DIP-Package ASD-5 Series, 5Watt MECHANICAL CONNECTION PIN # SINGLE 1 AC(N) 2 AC(L) 3 +Vo 4 -Vo Note: Unit is mm(inch). ELECTRICAL CURVE DERATING CURVE www.pairuigroup.com STATIC CHARACTERISTIC CURVE Page: 3 / 4 Date: 11/09/2015 *Subject to change without notice AC-DC Converter DIP-Package ASD-5 Series, 5Watt NOTE BLOCK DIAGRAM RECOMMENDED TEST AND APPLICATION CIRCUIT EMC RECOMMENDED APPLICATION CIRCUIT 3.3VDC 5VDC 9VDC 12VDC F1 T1A/250V RT1 7D471K R1, R2 2Ω/3W R3 1MΩ/2W L1 L=3-10mH,I=0.2-0.5A CX1, CX2 0.15-1μF/300Vac CY1, CY2 102K/400Vac C3 1μF/50V 15VDC 24VDC C4 470uF/16V 470uF/16V 150uF/25V 120uF/25V 120uF/25V 100uF/35V Z1 P6KE6.8A P6KE6.8A P6KE16A P6KE16A P6KE20A P6KE33A www.pairuigroup.com Page: 4 / 4 Date: 11/09/2015 *Subject to change without notice