Click on Series name for product info on aimtec.com Series AMEPR30C-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter FEATURES: Models Single output • AC-DC Constant Current or Constant Voltage LED Driver • Input range 90-305VAC/47-440Hz • High efficiency up to 83% • Operating temperature -40 to 85°C • Dimmable via resistive / 0-10Vdc / PWM • 5 Years Limited Warranty • • • • • Max Output Power (W)① Output Voltage Range (V)③ Output Current (A)③ Input Voltage (VAC/Hz) Input Voltage (VDC) AMEPR30C-5070AZ 35 36-50 0.7 90-305/47-440 130-430 AMEPR30C-4864AZ 30.7 36-48 0.64 90-305/47-440 130-430 AMEPR30C-36100AZ 36 24-36 1 90-305/47-440 130-430 AMEPR30C-24140AZ 33.6 12-24 1.4 90-305/47-440 130-430 AMEPR30C-12250AZ 30 5-12 2.5 90-305/47-440 130-430 Model ① Over temperature protection Over current protection Waterproof case rated IP68 Power Factor Correction Short circuit protection Mode of Operation Efficiency (%) 115 230 277 83 83 83 83 83 83 82 82 80 80 83 83 83 83 83 83 82 82 80 80 83 83 83 83 83 83 82 82 80 80 VAC Constant Current ② Constant Voltage Constant Current ② Constant Voltage Constant Current ② Constant Voltage Constant Current ② Constant Voltage Constant Current ② Constant Voltage VAC VAC Exceeding the maximum output power will permanently damage the converter. The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming option in the case. ③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when ordering. ② NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-sale AMEPR30C-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current Power factor External fuse Start-up time www.aimtec.com F 052.1e R3.C Conditions Typical 115 VAC 230 VAC 277 VAC 115 VAC 230 VAC 277 VAC I/O I/FG, O/FG 115 VAC 230 VAC 277 VAC Recommended slow blow type 0.96 0.90 0.85 1 450 Tel: +1 514 620 2722 1 of 9 Maximum 430 250 210 25 40 55 0.25 3.5 Units mA mA mA A A A mA mA A ms Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30C-AZ Output Specifications Parameters Current accuracy Line regulation Load regulation Ripple & Noise* Hold-up time Current adjustment range up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Conditions Typical Maximum ±3 ±2 ±3 100 50 100-10 (LL-HL) 0-100% load Units % % % mV p-p ms % *Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor. Isolation Specifications Parameters Tested voltage Isolation Resistance I/O I/FG O/FG General Specifications Parameters Switching frequency Over current protection Over voltage protection Short circuit protection Over temperature protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting Wires Weight Dimensions MTBF Conditions Typical 500VDC >1000 3sec Conditions Rated Units 3750 2000 500 VAC VAC VAC MΩ Typical 130 ≧105 ≧105 Auto recovery 125°C Refer to model application Detect case temperature With derating over °C Maximum Units 100 C C o C o C % / oC KHz % % o o -40 to +95 ±0.02 Free air convection Non condensing 20~95 Plastic Epoxy (IP68 rated) UL1015 18AWG * 20CM 540 137.33 x 60 x 40.50 mm (5.41 x 2.36 x 1.59 inches) >400,000 hrs (MIL-HDBK-217F at t=+25°C) % RH g Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052.1e R3.C cULus, CE UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13 Information Technology Equipment EN55022 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 1 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Tel: +1 514 620 2722 2 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30C-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Dimensions £X 1.00 (£ X 0.04) ¡ Ó ¡ Ó Analog (Resistive) Dimming Application Circuit AC BROWN L GREEN +Vout AMEPR30-AZ BLUE N F 052.1e R3.C 1 1st LED BLUE Model Number AMEPR30C-5070AZ -Vout AMEPR30C-4864AZ 1 WHITE www.aimtec.com RED BLACK AMEPR30C-36100AZ AMEPR30C-24140AZ Pot AMEPR30C-12250AZ Tel: +1 514 620 2722 3 of 9 Maximum Pot Value (kΩ) See graphs below See graphs below See graphs below See graphs below See graphs below Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30C-AZ Dimming Performance Graphs AMEPR30C-4864AZ www.aimtec.com F 052.1e R3.C up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Tel: +1 514 620 2722 4 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30C-AZ AMEPR30C-5070AZ www.aimtec.com F 052.1e R3.C up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Tel: +1 514 620 2722 5 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30C-AZ AMEPR30C-12250AZ www.aimtec.com F 052.1e R3.C up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Tel: +1 514 620 2722 6 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30C-AZ AMEPR30C-24140AZ www.aimtec.com F 052.1e R3.C up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Tel: +1 514 620 2722 7 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30C-AZ AMEPR30C-36100AZ www.aimtec.com F 052.1e R3.C up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Tel: +1 514 620 2722 8 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR30C-AZ up to 2.5A | AC-DC / DC-DC | LED Driver / Converter Derating Free Air Convection 55 º C 100 80 Safe Operating Area 60 40 20 0 -40 -20 0 20 40 60 80 85 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.C Tel: +1 514 620 2722 9 of 9 Toll free: + 1 888 9 AIMTEC (924 6832) North America only