AHM85 Series GREEN POWER • Medical & IT Safety Approvals • Energy Star Level V • CEC 2008 & EISA 2007 Compliant • IP22 Environmental Rating • Compact Format 5.90”x 2.52”x 1.45” • <0.5 W Standby Power • 85 W - Convection Cooled Ratings • Class I & Class II Models • 0 ºC to +60 ºC Operation • Very Low Earth Leakage Current • 3 Year Warranty The AHM85 series of medical external power supplies is fully approved to international medical safety standards. It has been designed with very high efficiency and low standby power, enabling it to meet the latest envirnomental legislation. The unit has a fully sealed enclosure complying with IP22 and a smooth surface finish making it easier to wipe down in a clinical setting. With approvals for class I and II the product is suitable for hospital, home healthcare and portable medial device applications. xppower.com Models and Ratings - Convection-cooled Output Power 85 W 85 W 85 W 85 W 85 W 85 W 85 W 85 W Output Voltage V1 12.0 VDC 15.0 VDC 19.0 VDC 24.0 VDC 12.0 VDC 15.0 VDC 19.0 VDC 24.0 VDC Max Output Current 7.08 A 5.67 A 4.47 A 3.54 A 7.08 A 5.67 A 4.47 A 3.54 A Notes: 1. Models with suffix ‘C2’ have a Class II equipment protection classification. Peak(2) Model Number(1) AHM85PS12 AHM85PS15 AHM85PS19 AHM85PS24 AHM85PS12C2 AHM85PS15C2 AHM85PS19C2 AHM85PS24C2 2. For optional input connector retention clip, add suffix ‘-A’ to the model number e.g. AHM85PS24C2-A. Input Characteristics Characteristic Minimum Input Voltage - Operating 80 Input Frequency Power Factor Input Current - No Load Input Current - Full Load Inrush Current No Load Input Power 47 Earth Leakage Current Input Protection Typical 115/230 Maximum 264 50/60 63 >0.9 0.05/0.09 0.8/0.4 60-80 120 0.3/0.4 0.5 50/85 180 0.3/0.6 T2.5A/250 V internal fuse in both lines Units Notes & Conditions VAC Full power 90 VAC to 264 VAC. Derate output power linearly by 20% from 90 VAC to 80 VAC. Hz A A A W µA mA EN61000-3-2 class A & D compliant & Energy Star Compliant 115/230 VAC 115/230 VAC 230 VAC cold start, 25 ºC 115/230 VAC 115 V 60 Hz/230 V 50 Hz (Typ.), 264 VAC/60 Hz (Max.) 115/230 VAC/400 Hz Output Characteristics Characteristic Output Voltage - V1 Minimum Typical 12 Maximum Units 48 VDC Output Voltage Adjustment Minimum Load % 0 See Models and Ratings table No user adjustment A Start Up Delay 200/100 ms Hold Up Time 15 ms 115/230 VAC full load (see fig.1) 115/230 VAC full load (see fig.2) Drift ±0.2 % After 20 min warm up Line Regulation ±0.5 % 90-264 VAC (50% load) Load Regulation ±3 % 0f50g100% load. % Recovery within 1% in less than 500 µs for a 50-75% and 7550% load step Transient Response - V1 5 Over/Undershoot - V1 3 Ripple & Noise <1 % 1.5 125 Overvoltage Protection Overload Protection % pk-pk % Temperature Coefficient Overtemperature Protection 20 MHz bandwidth with external circuit (see fig.3-6) Vnom, Recycle AC to reset 13.2 18 AHM85PS12 & C2 16.5 22 AHM85PS15 & C2 21.0 28 26.4 33 115.0 175 8.5 12.0 AHM85PS12 & C2 6.8 9.6 AHM85PS15 & C2 4.9 7.6 4.2 6.0 VDC AHM85PS19 & C2 AHM85PS24 & C2 % A I nom, Auto reset AHM85PS19 & C2 AHM85PS24 & C2 Short Circuit Protection 2 Notes & Conditions Continuous, trip & restart (hiccup mode) 0.05 %/˚C °C Connected to transformer. Auto reset. xppower.com Start Up Delay From AC Turn On Figure 1 Start up example from AC turn on (230 VAC, 79 ms) Hold Up Time From Loss of AC Figure 2 Hold up example at 85 W load with 230 VAC input (19 ms) 3 xppower.com Ripple & Noise Figure 3 AHM85PS12 Ripple & noise example at 85 W load with 230 VAC input (75 mV) Figure 4 AHM85PS24 Ripple & noise example at 85 W load with 230 VAC input (77 mV) Figure 6 Ripple & noise measurement circuit 10 µF Electrolytic 4 0.1 µF Ceramic xppower.com Xxxxxxxxxx General Specifications Characteristic Efficiency Isolation: Input to Output Input to Ground Output to Ground Minimum Typical 92 Maximum 4000 1500 500 45 90 Switching Frequency Units % VAC VAC VAC 200 110 3.9 Power Density Mean Time Between Failure Weight kHz W/in3 kHrs lb (g) 172 0.9 (400) Notes & Conditions Full load (see fig.7-8) Class I Models Class I Models PFC stage DC-DC stage MIL-HDBK-217F, Notice 2 +25 °C GB Average Active Efficiency Characteristic Average Active Efficiency 115 V / 60 Hz 230 VAC / 50 Hz AHM85PS12 & C2 90.41 89.92 AHM85PS15 & C2 89.37 88.99 AHM85PS19 & C2 90.36 89.93 AHM85PS24 & C2 91.67 91.23 Units Notes & Conditions % As per Energy Star Level V test procedure Efficiency Versus Load 100% 90% 80% Efficiency 70% 60% 50% 40% 30% 20% 10% 0% 10 20 30 40 50 60 70 80 90 100 Load (%) Figure 7 - AHM85PS12 115Vac input 230Vac input 100% 90% 80% Efficiency 70% 60% 50% 40% 30% 20% 10% 0% 10 20 30 40 50 60 70 80 90 100 Load (%) Figure 8 - AHM85PS24 5 xppower.com Xxxxxxxxxx Environmental Characteristic Minimum Operating Temperature Typical Maximum 0 Units Notes & Conditions +60 ºC Derate linearly to 60% load at 60 ºC from +40 °C. (See fig.9) 71 ºC 100% Load, with TAMB +40 ºC Case Temperature (IEC60601 3rd Edition) 60 90% Load Maximum, with TAMB +40 ºC 48 Storage Temperature 10% Load Maximum, with TAMB +40 ºC -40 +85 ºC 5 95 %RH 3000 m Cooling Convection cooled, see fig.9 Humidity Operating Altitude Ingress Protection Non-condensing IP22 Shock 3 x 30 g/11 ms shocks in both +ve & -ve directions along the 3 orthogonal axis, total 18 shocks. Vibration Three axis 5-500 Hz at 2 g x 10 sweeps Derating Curve Figure 9 Output Power (%) 100% 60% 0 20 Ambient Temperature (ºC) 10 60 40 Electromagnetic Compatibility - Immunity Phenomenon Standard Test Level Criteria EN61204-3 High severity level as below Harmonic Current EN61000-3-2 Class A ESD EN61000-4-2 3 A Radiated EN61000-4-3 3 A EFT EN61000-4-4 3 A Surges EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 3 A Magnetic Field EN61000-4-8 3 Low Voltage PSU EMC EN61000-4-11 Dips and Interruptions EN60601-1-2 6 Notes & Conditions A Dip: 30% 500 ms A Dip: 60% 200 ms B Dip: 80% 5000 ms A Dip: 100% 5000 ms B Dip: 30% 25 AC Cycles A 230 VAC 100% load, 100 VAC 80% load Dip: 60% 5 AC Cycles A 230 VAC 100% load, 100 VAC 15% load Dip: 100% 0.5 AC Cycles A Int.: >95% 5000 ms B xppower.com Xxxxxxxxxx Electromagnetic Compatibility - Emissions Phenomenon Standard Test Level EN55011/22 Class B Radiated EN55011/22 Class B Voltage Fluctuations EN61000-3-3 Conducted Criteria Notes & Conditions Safety Agency Approvals Safety Agency Safety Standard CB Report Certificate # US/15675/UL, IEC60950-1:2005 Ed 2 Category Information Technology UL UL File # E139109-A57-UL-1, UL60950-1 Ed 2 (2007), CSA 22.2 No.60950-1-07 Ed 2 Information Technology TUV TUV Certificate # Z1A 10 12 57396 085, EN60950-1:2006 Information Technology Denan Japan PSE Certificate CE LVD Safety Agency Safety Standard Category CB Report Certificate #US/16953/UL, IEC60601-1 Ed 3 Including Risk Management Medical UL UL File # E146893-V1-S8, ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08 Medical TUV TUV Certificate # B11 06 57396 102, EN60601-1:2006 Medical Primary to Secondary 2 x MOPP (Means of Patient Protection) Primary to Earth 1 x MOPP (Means of Patient Protection) Secondary to Earth 1 x MOPP (Means of Patient Protection) Equipment Protection Class Safety Standard Notes & Conditions IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 3 See safety agency conditions of acceptibility for details Means of Protection Class I & Class II Category IEC60601-1 Ed 3 Environmental Legislation Authority Location Date EISA US 2007 CEC California, US 2008 Notes & Conditions Energy Star US 2008 Level V ErP Directive Europe 2011 Regulation No. 278/2009 7 xppower.com Xxxxxxxxxx Details Mechanical Weight: 0.9 lbs (400 g) Dimensions shown in inches (mm). 5.9 (150.0) 36.4 (900.0) 0.79 (Ø20) 2.52 (64.0) 1.4 (36.0) 5.12 (130.0) IEC320-C14 1.45 (37.0) 3.02 (76.9) 1.57 (40.0) 1.55 (39.4) 5.11 (130.0) Shell Optional Input Connector Retention (-A) 2 1 4 Standard (Class I) C2 Models (Class II) C2-8 Models (Class II) 3 1.40 (35.7) Output Connector equivalent to KPPX-4P (Non Locking) IEC 320-C14 IEC 320-C18 IEC 320-C8 Pin 1 Pin 2 Pin 3 Pin 4 Outer Shell Output + Output + Return Return GND* Outer Shell C2 Models Floating * Functional earth. 8 29-Sept-14 AHM100 Series GREEN POWER • Medical & IT Safety Approvals • Energy Star Level V • CEC 2008 & EISA 2007 Compliant • IP22 Environmental Rating • Compact Format 6.50” x 2.52” x 1.46” • <0.5 W Standby Power • 100 W - Convection Cooled Ratings • Class I & Class II Models • 0 ºC to +60 ºC Operation • Very Low Earth Leakage Current • 3 Year Warranty The AHM100 series of medical external power supplies is fully approved to international medical safety standards. It has been designed with very high efficiency and low standby power, enabling it to meet the latest envirnomental legislation. The unit has a fully sealed enclosure complying with IP22 and a smooth surface finish making it easier to wipe down in a clinical setting. With approvals for class I and II the product is suitable for hospital, home healthcare and portable medial device applications. xppower.com Models and Ratings - Convection-cooled Output Power 100 W 100 W 100 W 90 W 100 W 100 W 100 W 100 W 100 W 90 W 100 W 100 W Output Voltage V1 12.0 VDC 15.0 VDC 19.0 VDC 24.0 VDC 24.0 VDC 48.0 VDC 12.0 VDC 15.0 VDC 19.0 VDC 24.0 VDC 24.0 VDC 48.0 VDC Max Output Current 8.33 A 6.67 A 5.26 A 3.75 A 4.16 A 2.08 A 8.33 A 6.67 A 5.26 A 3.75 A 4.16 A 2.08 A Notes: 1. Models with suffix ‘C2’ have a Class II equipment protection classification. 2. Maximum peak duration 300 ms, average power must not exceed 90 W. Peak(2) 7A 7A Model Number(1) AHM100PS12 AHM100PS15 AHM100PS19 AHM100PS24P(3) AHM100PS24 AHM100PS48 AHM100PS12C2 AHM100PS15C2 AHM100PS19C2 AHM100PS24C2P(3) AHM100PS24C2 AHM100PS48C2 3. Peak models are not standard product. Contact sales for details and availability. 4. For optional input connector retention clip, add suffix ‘-A’ to the model number e.g. AHM100PS24C2-A. Input Characteristics Characteristic Minimum Input Voltage - Operating 80 Input Frequency Power Factor Input Current - No Load Input Current - Full Load Inrush Current No Load Input Power 47 Earth Leakage Current Input Protection Typical 115/230 Maximum 264 50/60 63 >0.9 0.05/0.09 1.0/0.5 60-80 120 0.3/0.4 0.5 50/85 180 0.3/0.6 T2.5A/250 V internal fuse in both lines Units Notes & Conditions VAC Full power 90 VAC to 264 VAC. Derate output power linearly by 20% from 90 VAC to 80 VAC. Hz A A A W µA mA EN61000-3-2 class A & D compliant & Energy Star Compliant 115/230 VAC 115/230 VAC 230 VAC cold start, 25 ºC 115/230 VAC 115 V 60 Hz/230 V 50 Hz (Typ.), 264 VAC/60 Hz (Max.) 115/230 VAC/400 Hz Output Characteristics Characteristic Output Voltage - V1 Minimum Typical 12 Maximum Units 48 VDC Output Voltage Adjustment Minimum Load % 0 See Models and Ratings table No user adjustment A Start Up Delay 200/100 ms Hold Up Time 20 ms 115/230 VAC full load (see fig.1) 115/230 VAC full load (see fig.2) Drift ±0.2 % After 20 min warm up Line Regulation ±0.5 % 90-264 VAC (50% load) Load Regulation ±3 % 0f50g100% load. 5 % Recovery within 1% in less than 500 µs for a 50-75% and 7550% load step 1.5 % pk-pk Transient Response - V1 Over/Undershoot - V1 3 Ripple & Noise <1 % 125 Overvoltage Protection Overload Protection % Temperature Coefficient Overtemperature Protection 20 MHz bandwidth with external circuit (see fig.3-6) Vnom, Recycle AC to reset 13.2 18 AHM100PS12 & C2 16.5 22 AHM100PS15 & C2 21.0 28 26.4 33 52.8 59 115.0 175 10.0 14.0 8.0 11.4 6.3 9.0 5.0 7.1 AHM100PS24 & C2 2.5 3.6 AHM100PS48 & C2 VDC AHM100PS19 & C2 AHM100PS24 & C2 AHM100PS48 & C2 % I nom, Auto reset AHM100PS12 & C2 AHM100PS15 & C2 A Short Circuit Protection 2 Notes & Conditions AHM100PS19 & C2 Continuous, trip & restart (hiccup mode) 0.05 %/˚C °C Connected to transformer. Auto reset. xppower.com Start Up Delay From AC Turn On Figure 1 Start up example from AC turn on (230 VAC, 95 ms) Hold Up Time From Loss of AC Figure 2 Hold up example at 100 W load with 230 VAC input (25 ms) 3 xppower.com Ripple & Noise Figure 3 AHM100PS12 Ripple & noise example at 100 W load with 230 VAC input (58 mV) Figure 4 AHM100PS24 Ripple & noise example at 100 W load with 230 VAC input (258 mV) Figure 5 AHM100PS48 Ripple & noise example at 100 W load with 230 VAC input (318 mV) Figure 6 Ripple & noise measurement circuit 10 µF Electrolytic 4 0.1 µF Ceramic xppower.com Xxxxxxxxxx General Specifications Characteristic Efficiency Isolation: Input to Output Input to Ground Output to Ground Minimum Typical 92 Maximum 4000 1500 500 45 90 Switching Frequency Units % VAC VAC VAC 200 110 4.4 Power Density Mean Time Between Failure Weight Notes & Conditions Full load (see fig.7-9) Class I Models Class I Models PFC stage DC-DC stage kHz W/in3 kHrs lb (g) 153 1.1 (500) MIL-HDBK-217F, Notice 2 +25 °C GB Average Active Efficiency GREEN Characteristic AHM100PS12 AHM100PS15 AHM100PS19 AHM100PS24 AHM100PS48 POWER Average Active Efficiency 115 V / 60 Hz 230 VAC / 50 Hz 90.52 90.32 89.88 89.64 89.99 89.74 91.67 91.43 91.80 91.63 & C2 & C2 & C2 & C2 & C2 Units Notes & Conditions % As per Energy Star Level V test procedure Efficiency Versus Load 100% 90% 80% Efficiency 70% 60% 50% 40% 30% 20% 10% 0% 10 20 30 40 50 60 70 80 90 100 Load (%) 100% 100% 90% 90% 80% 80% 70% 70% 60% 60% Efficiency Efficiency Figure 7 - AHM100PS12 50% 40% 50% 40% 30% 30% 20% 20% 10% 10% 0% 0% 10 20 30 40 50 60 70 80 90 100 10 Load (%) 20 30 40 50 60 70 80 90 100 Load (%) Figure 8 - AHM100PS24 Figure 9 - AHM100PS48 115Vac input 230Vac input 5 xppower.com Xxxxxxxxxx Environmental Characteristic Minimum Operating Temperature Typical Maximum 0 Units Notes & Conditions +60 ºC Derate linearly to 60% load at 60 ºC from +40 °C. (See fig.10) 71 ºC 100% Load, with TAMB +40 ºC Case Temperature (IEC60601 3rd Edition) 60 80% Load Maximum, with TAMB +40 ºC 48 Storage Temperature 10% Load Maximum, with TAMB +40 ºC -40 +85 ºC 5 95 %RH 3000 m Cooling Convection cooled, see fig.10 Humidity Operating Altitude Ingress Protection Non-condensing IP22 Shock 3 x 30 g/11 ms shocks in both +ve & -ve directions along the 3 orthogonal axis, total 18 shocks. Vibration Three axis 5-500 Hz at 2 g x 10 sweeps Derating Curve Figure 10 Output Power (%) 100% 60% 0 20 Ambient Temperature (ºC) 10 60 40 Electromagnetic Compatibility - Immunity Phenomenon Standard Test Level Criteria EN61204-3 High severity level as below Harmonic Current EN61000-3-2 Class A ESD EN61000-4-2 3 A Radiated EN61000-4-3 3 A EFT EN61000-4-4 3 A Surges EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 3 A Magnetic Field EN61000-4-8 3 Low Voltage PSU EMC EN61000-4-11 Dips and Interruptions EN60601-1-2 6 Notes & Conditions A Dip: 30% 500 ms A Dip: 60% 200 ms B Dip: 80% 5000 ms A Dip: 100% 5000 ms B Dip: 30% 25 AC Cycles A 230 VAC 100% load, 100 VAC 80% load Dip: 60% 5 AC Cycles A 230 VAC 100% load, 100 VAC 15% load Dip: 100% 0.5 AC Cycles A Int.: >95% 5000 ms B xppower.com Xxxxxxxxxx Electromagnetic Compatibility - Emissions Phenomenon Standard Test Level EN55011/22 Class B Radiated EN55011/22 Class B Voltage Fluctuations EN61000-3-3 Conducted Criteria Notes & Conditions Safety Agency Approvals Safety Agency Safety Standard CB Report Certificate # US/15053A/UL, IEC60950-1:2005 Ed 2 Category Information Technology UL UL File # E139109-A45-UL-1, UL60950-1 Ed 2 (2007), CSA 22.2 No.60950-1-07 Ed 2 Information Technology TUV TUV Certificate # Z1A 10 07 57396 078, EN60950-1:2006 Information Technology Denan Japan PSE Certificate CE LVD Safety Agency Safety Standard Category CB Report Certificate #US/18097/UL, IEC60601-1 Ed 3 Including Risk Management Medical UL UL File # E146893, ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08 Medical TUV TUV Certificate # Z11 12 57396 122, EN60601-1:2006 Medical Primary to Secondary 2 x MOPP (Means of Patient Protection) Primary to Earth 1 x MOPP (Means of Patient Protection) Secondary to Earth 1 x MOPP (Means of Patient Protection) Equipment Protection Class Safety Standard Notes & Conditions IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 3 See safety agency conditions of acceptibility for details Means of Protection Class I & Class II Category IEC60601-1 Ed 3 Environmental Legislation Authority Location Date EISA US 2007 CEC California, US 2008 Notes & Conditions Energy Star US 2008 Level V ErP Directive Europe 2011 Regulation No. 278/2009 7 xppower.com Xxxxxxxxxx Details Mechanical Weight: 1.1 lbs (500 g) Dimensions shown in inches (mm). 6.29 (160.0) 36.4 (900.0) 0.2 (5.0) 0.79 (Ø20) 2.52 (64.0) 5.12 (130.0) 1.4 (36.0) 1.45 (37.0) 3.02 (76.9) 1.57 (40.0) 1.55 (39.4) 5.11 (130.0) Shell Optional Input Connector Retention (-A) 2 1 4 Standard (Class I) C2 Models (Class II) C2-8 Models (Class II) 3 1.40 (35.7) Output Connector equivalent to KPPX-4P (Non Locking) IEC 320-C14 IEC 320-C18 IEC 320-C8 Pin 1 Pin 2 Pin 3 Pin 4 Outer Shell Output + Output + Return Return GND* Outer Shell C2 Models Floating * Functional earth. 8 29-Sept-14 AHM150 Series GREEN POWER • Medical & IT Safety Approvals • Energy Star Level V • CEC 2008 & EISA 2007 Compliant • IP22 Environmental Rating • Compact Format 7.80” x 3.15” x 1.45” • <0.5 W Standby Power • 150 W - Convection Cooled Ratings • Class I & Class II Models • 0 ºC to +60 ºC Operation • Very Low Earth Leakage Current • 3 Year Warranty The AHM150 series of medical external power supplies is fully approved to international medical safety standards. It has been designed with very high efficiency and low standby power, enabling it to meet the latest envirnomental legislation. The unit has a fully sealed enclosure complying with IP22 and a smooth surface finish making it easier to wipe down in a clinical setting. With both medical & IT approvals in class I and class II formats the product is suitable for hospital, home healthcare, portable medial device applications and a wide range of IT applications. xppower.com Models and Ratings - Convection-cooled Output Power 150 W 150 W 150 W 150 W 150 W 150 W 150 W 150 W 150 W 150 W Output Voltage V1 12.0 VDC 15.0 VDC 19.0 VDC 24.0 VDC 48.0 VDC 12.0 VDC 15.0 VDC 19.0 VDC 24.0 VDC 48.0 VDC Max Output Current 12.50 A 10.00 A 7.89 A 6.25 A 3.13 A 12.50 A 10.00 A 7.89 A 6.25 A 3.13 A Model Number(1) AHM150PS12 AHM150PS15 AHM150PS19 AHM150PS24 AHM150PS48 AHM150PS12C2 AHM150PS15C2 AHM150PS19C2 AHM150PS24C2 AHM150PS48C2 Notes: 1. For optional input connector retention clip, add suffix -A’ ‘ to the model number e.g. AHM150PS24-A. Models with suffix C2’ ‘ have a class II equipment protection classification. For IEC320-C8 input connector with class II models, add suffix -8’ ‘ to the model number, e.g. AHM150PS24C2-8. Input Characteristics Characteristic Minimum Input Voltage - Operating 80 Input Frequency Power Factor Input Current - No Load Input Current - Full Load Inrush Current No Load Input Power 47 Earth Leakage Current Input Protection Typical 115/230 Maximum 264 50/60 63 >0.9 0.06/0.04 1.4/0.7 60-80 120 0.3/0.4 0.5 50/100 200 0.3/0.6 T4.0A/250 V internal fuse in both lines Units Notes & Conditions VAC Full power 90 VAC to 264 VAC. Derate output power linearly by 20% from 90 VAC to 80 VAC. Hz A A A W µA mA EN61000-3-2 class A & D compliant & Energy Star Compliant 115/230 VAC 115/230 VAC 230 VAC cold start, 25 ºC 115/230 VAC 115 V 60 Hz/230 V 50 Hz (Typ.), 264 VAC/60 Hz (Max.) 115/230 VAC/400 Hz Output Characteristics Characteristic Output Voltage - V1 Minimum Typical 12 Maximum Units 48 VDC Output Voltage Adjustment Minimum Load % 0 See Models and Ratings table No user adjustment A Start Up Delay 200/100 ms Hold Up Time 10 ms 115/230 VAC full load (see fig.1) 115/230 VAC full load (see fig.2) Drift ±0.2 % After 20 min warm up Line Regulation ±0.5 % 90-264 VAC (50% load) Load Regulation ±4 % 0f50g100% load. 5 % Recovery within 1% in less than 500 µs for a 50-75% and 7550% load step 1.5 % pk-pk Transient Response - V1 Over/Undershoot - V1 3 Ripple & Noise <1 % 125 Overvoltage Protection Overload Protection % Temperature Coefficient Overtemperature Protection 20 MHz bandwidth with external circuit (see fig.3-6) Vnom, Recycle AC to reset 13.2 18 AHM150PS12 & C2 16.5 22 AHM150PS15 & C2 20.9 28 26.4 33 52.8 59 115.0 175 15.0 21.3 12.0 17.0 8.7 13.4 6.8 10.6 AHM150PS24 & C2 3.7 5.3 AHM150PS48 & C2 VDC AHM150PS19 & C2 AHM150PS24 & C2 AHM150PS48 & C2 % I nom, Auto reset AHM150PS12 & C2 AHM150PS15 & C2 A Short Circuit Protection 2 Notes & Conditions AHM150PS19 & C2 Continuous, trip & restart (hiccup mode) 0.05 %/˚C °C Connected to transformer. Auto reset. xppower.com Start Up Delay From AC Turn On Figure 1 Start up example from AC turn on (230 VAC, 196 ms) Hold Up Time From Loss of AC Figure 2 Hold up example at 150 W load with 230 VAC input (16 ms) 3 xppower.com Ripple & Noise Figure 3 AHM150PS12 Ripple & noise example at 150 W load with 230 VAC input (60 mV) Figure 4 AHM150PS24 Ripple & noise example at 150 W load with 230 VAC input (137 mV) Figure 5 AHM150PS48 Ripple & noise example at 150 W load with 230 VAC input (296 mV) Figure 6 Ripple & noise measurement circuit 10 µF Electrolytic 4 0.1 µF Ceramic xppower.com Xxxxxxxxxx General Specifications Characteristic Efficiency Isolation: Input to Output Input to Ground Output to Ground Minimum Typical 92 Maximum 4000 1500 500 30 90 Switching Frequency Units % VAC VAC VAC 200 110 4.2 Power Density Mean Time Between Failure Weight 163 1.3 (600) Notes & Conditions Full load (see fig.7-9) kHz PFC stage DC-DC stage W/in3 kHrs lb (g) MIL-HDBK-217F, Notice 2 +25 °C GB Average Active Efficiency GREEN POWER Average Active Efficiency 115 V / 60 Hz 230 VAC / 50 Hz 90.31 91.74 91.44 91.78 92.00 92.52 91.46 92.99 92.38 92.85 Characteristic AHM150PS12 AHM150PS15 AHM150PS19 AHM150PS24 AHM150PS48 Units Notes & Conditions % As per Energy Star Level V test procedure Efficiency Versus Load 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 10 20 30 40 50 60 70 80 90 100 Load (%) Figure 7 - AHM150PS12 100% 100% 90% 90% 80% 80% 70% 70% 60% 60% 50% 50% 40% 40% 30% 30% 20% 20% 10% 10% 0% 0% 10 20 30 40 50 60 70 80 90 10 100 20 30 40 50 60 70 80 90 100 Load (%) Load (%) Figure 8 - AHM150PS24 Figure 9 - AHM150PS48 115Vac input 230Vac input 5 xppower.com Xxxxxxxxxx Environmental Characteristic Minimum Operating Temperature Typical Maximum 0 Units Notes & Conditions +60 ºC Derate linearly to 60% load at 60 ºC from +40 °C. (See fig.10) 71 ºC 100% Load, with TAMB +40 ºC Case Temperature (IEC60601 3rd Edition) 60 70% Load Maximum, with TAMB +40 ºC 48 Storage Temperature 10% Load Maximum, with TAMB +40 ºC -40 +85 ºC 5 95 %RH 3000 m Cooling Convection cooled, see fig.10 Humidity Operating Altitude Ingress Protection Non-condensing IP22 Shock 3 x 30 g/11 ms shocks in both +ve & -ve directions along the 3 orthogonal axis, total 18 shocks. Vibration Three axis 5-500 Hz at 2 g x 10 sweeps Derating Curve Figure 10 Output Power (%) 100% 60% 0 20 Ambient Temperature (ºC) 10 60 40 Electromagnetic Compatibility - Immunity Phenomenon Standard Test Level Criteria EN61204-3 High severity level as below Harmonic Current EN61000-3-2 Class A ESD EN61000-4-2 3 A Radiated EN61000-4-3 3 A EFT EN61000-4-4 3 A Surges EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 3 A Magnetic Field EN61000-4-8 3 Low Voltage PSU EMC EN61000-4-11 Dips and Interruptions EN60601-1-2 6 Notes & Conditions A Dip: 30% 500 ms A Dip: 60% 200 ms B Dip: 80% 5000 ms A Dip: 100% 5000 ms B Dip: 30% 25 AC Cycles A 230 VAC 100% load, 100 VAC 80% load Dip: 60% 5 AC Cycles A 230 VAC 100% load, 100 VAC 15% load Dip: 100% 0.5 AC Cycles A Int.: >95% 5000 ms B xppower.com Xxxxxxxxxx Electromagnetic Compatibility - Emissions Phenomenon Standard Test Level EN55011/22 Class B Radiated EN55011/22 Class B Voltage Fluctuations EN61000-3-3 Conducted Criteria Notes & Conditions Safety Agency Approvals Safety Agency Safety Standard CB Report Certificate # US/16498/UL IEC60950-1:2005 Ed 2 Information Technology UL UL File #E139109-A62-UL UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2 Information Technology TUV TUV Certificate # Z1A 11 02 57396 093, EN60950-1:2006 Information Technology Denan Japan PSE Certificate CE LVD Safety Agency Category Safety Standard Category CB Report Certificate #US/17207/UL, IEC60601-1 Ed 3 Including Risk Management Medical UL UL File # E146893-V1-S9, ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08 Medical TUV TUV Certificate # B11 07 57396 105, EN60601-1:2006 Medical Means of Protection Category Primary to Secondary 2 x MOPP (Means of Patient Protection) Primary to Earth 1 x MOPP (Means of Patient Protection) Secondary to Earth 1 x MOPP (Means of Patient Protection) Equipment Protection Class Safety Standard Notes & Conditions IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 3 See safety agency conditions of acceptibility for details Class I & Class II IEC60601-1 Ed 3 Environmental Legislation Authority Location Date EISA US 2007 CEC California, US 2008 Notes & Conditions Energy Star US 2008 Level V ErP Directive Europe 2011 Regulation No. 278/2009 7 xppower.com Xxxxxxxxxx Details Mechanical Weight: 1.3 lbs (600 g) Dimensions shown in inches (mm). 7.8 (200.0) 36.4 (900.0) 0.19 (4.9) 0.79 (Ø20) 3.15 (80.0) 1.4 (36.0) 5.12 (130.0) IEC320-C14 1.45 (37.0) 3.94 (100.3) 2.02 (51.5) 1.58 (40.30) 6.8 (173.0) Shell Optional Input Connector Retention (-A) 2 Standard (Class I) C2 Models (Class II) C2-8 Models (Class II) 1.40 (35.7) 1 4 3 Output Connector equivalent to KPPX-4P (Non Locking) IEC 320-C14 IEC 320-C18 IEC 320-C8 Pin 1 Pin 2 Pin 3 Pin 4 Outer Shell Output + Output + Return Return GND* Outer Shell C2 Models Floating * Functional earth. 8 29-Sept-14 AHM180 Series GREEN POWER • Medical & IT Safety Approvals • Energy Star Level V • CEC 2008 & EISA 2007 Compliant • IP22 Environmental Rating • Compact Format 7.90” x 3.15” x 1.61” • <0.5 W Standby Power • 180 W - Convection Cooled Ratings • Class I & Class II Models • 0 ºC to +60 ºC Operation • Very Low Earth Leakage Current • 3 Year Warranty The AHM180 series of medical external power supplies is fully approved to international medical safety standards. It has been designed with very high efficiency and low standby power, enabling it to meet the latest envirnomental legislation. The unit has a fully sealed enclosure complying with IP22 and a smooth surface finish making it easier to wipe down in a clinical setting. With both medical & IT approvals the product is suitable for hospital, home healthcare, portable medial device applications and a wide range of IT applications. xppower.com Models and Ratings - Convection-cooled Output Power 165 W 180 W 180 W 180 W 180 W 165 W 180 W 180 W 180 W 180 W Output Voltage V1 12.0 VDC 15.0 VDC 19.0 VDC 24.0 VDC 48.0 VDC 12.0 VDC 15.0 VDC 19.0 VDC 24.0 VDC 48.0 VDC Max Output Current 13.75 A 12.00 A 9.47 A 7.50 A 3.75 A 13.50 A 12.00 A 9.47 A 7.50 A 3.75 A Model Number(1) AHM180PS12 AHM180PS15 AHM180PS19 AHM180PS24 AHM180PS48 AHM180PS12C2 AHM180PS15C2 AHM180PS19C2 AHM180PS24C2 AHM180PS48C2 Notes: 1. For optional input connector retention clip, add suffix -A’ ‘ to the model number e.g. AHM180PS24-A. Models with suffix C2’ ‘ have a class II equipment protection classification. For IEC320-C8 input connector with class II models, add suffix -8’ ‘ to the model number, e.g. AHM180PS24C2-8. Input Characteristics Characteristic Minimum Input Voltage - Operating 80 Input Frequency Power Factor Input Current - No Load Input Current - Full Load Inrush Current No Load Input Power 47 Earth Leakage Current Input Protection Typical 115/230 Maximum 264 50/60 63 >0.9 0.08/0.05 1.7/0.9 60-80 120 0.3/0.4 0.5 50/100 200 0.3/0.6 T4.0A/250 V internal fuse in both lines Units Notes & Conditions VAC Full power 90 VAC to 264 VAC. Derate output power linearly by 20% from 90 VAC to 80 VAC. Hz A A A W µA mA EN61000-3-2 class A & D compliant & Energy Star Compliant 115/230 VAC 115/230 VAC 230 VAC cold start, 25 ºC 115/230 VAC 115 V 60 Hz/230 V 50 Hz (Typ.), 264 VAC/60 Hz (Max.) 115/230 VAC/400 Hz Output Characteristics Characteristic Output Voltage - V1 Minimum Typical 12 Maximum Units 48 VDC Output Voltage Adjustment Minimum Load % 0 See Models and Ratings table No user adjustment A Start Up Delay 200/100 ms Hold Up Time 15 ms 115/230 VAC full load (see fig.1) 115/230 VAC full load (see fig.2) Drift ±0.2 % After 20 min warm up Line Regulation ±0.5 % 90-264 VAC (50% load) Load Regulation ±4 % 0f50g100% load. 5 % Recovery within 1% in less than 500 µs for a 50-75% and 7550% load step 1.5 % pk-pk Transient Response - V1 Over/Undershoot - V1 3 Ripple & Noise <1 % 125 Overvoltage Protection Overload Protection % Temperature Coefficient Overtemperature Protection 20 MHz bandwidth with external circuit (see fig.3-6) Vnom, Recycle AC to reset 13.2 18 AHM180PS12 & C2 16.5 22 AHM180PS15 & C2 20.9 28 26.4 33 52.8 59 115.0 175 16.5 23.4 14.4 20.4 10.4 16.1 8.3 12.8 AHM180PS24 & C2 4.5 6.4 AHM180PS48 & C2 VDC AHM180PS19 & C2 AHM180PS24 & C2 AHM180PS48 & C2 % I nom, Auto reset AHM180PS12 & C2 AHM180PS15 & C2 A Short Circuit Protection 2 Notes & Conditions AHM180PS19 & C2 Continuous, trip & restart (hiccup mode) 0.05 %/˚C °C Connected to transformer. Auto reset. xppower.com Start Up Delay From AC Turn On Figure 1 Start up example from AC turn on (230 VAC, 196 ms) Hold Up Time From Loss of AC Figure 2 Hold up example at 180 W load with 230 VAC input (23 ms) 3 xppower.com Ripple & Noise Figure 3 AHM180PS12 Ripple & noise example at 165 W load with 230 VAC input (50 mV) Figure 4 AHM180PS24 Ripple & noise example at 180 W load with 230 VAC input (228 mV) Figure 5 AHM180PS48 Ripple & noise example at 180 W load with 230 VAC input (360 mV) Figure 6 Ripple & noise measurement circuit 10 µF Electrolytic 4 0.1 µF Ceramic xppower.com Xxxxxxxxxx General Specifications Characteristic Efficiency Isolation: Input to Output Input to Ground Output to Ground Minimum Typical 92 Maximum 4000 1500 500 30 90 Switching Frequency Units % VAC VAC VAC 200 110 4.4 Power Density Mean Time Between Failure Weight 156 1.4 (620) Average Active Efficiency GREEN AHM180PS12 AHM180PS15 AHM180PS19 AHM180PS24 AHM180PS48 kHz PFC stage DC-DC stage W/in3 kHrs lb (g) MIL-HDBK-217F, Notice 2 +25 °C GB POWER Average Active Efficiency 115 V / 60 Hz 230 VAC / 50 Hz 90.19 91.25 91.13 92.26 91.28 92.44 91.67 92.83 92.11 93.12 Characteristic Notes & Conditions Full load (see fig.7-9) Units Notes & Conditions % As per Energy Star Level V test procedure Efficiency Versus Load 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 10 20 30 40 50 60 70 80 90 100 Load (%) Figure 7 - AHM180PS12 100% 100% 90% 90% 80% 80% 70% 70% 60% 60% 50% 50% 40% 40% 30% 30% 20% 20% 10% 10% 0% 0% 10 20 30 40 50 60 70 80 90 10 100 20 30 40 50 60 70 80 90 100 Load (%) Load (%) Figure 8 - AHM180PS24 Figure 9 - AHM180PS48 115Vac input 230Vac input 5 xppower.com Xxxxxxxxxx Environmental Characteristic Minimum Operating Temperature Typical Maximum 0 Units Notes & Conditions +60 ºC Derate linearly to 60% load at 60 ºC from +40 °C. (See fig.10) 71 ºC 100% Load, with TAMB +40 ºC Case Temperature (IEC60601 3rd Edition) 60 60% Load Maximum, with TAMB +40 ºC 48 Storage Temperature 5% Load Maximum, with TAMB +40 ºC -40 +85 ºC 5 95 %RH 3000 m Cooling Convection cooled, see fig.10 Humidity Operating Altitude Ingress Protection Non-condensing IP22 Shock 3 x 30 g/11 ms shocks in both +ve & -ve directions along the 3 orthogonal axis, total 18 shocks. Vibration Three axis 5-500 Hz at 2 g x 10 sweeps Derating Curve Figure 10 Output Power (%) 100% 60% 0 20 Ambient Temperature (ºC) 10 60 40 Electromagnetic Compatibility - Immunity Phenomenon Standard Test Level Criteria EN61204-3 High severity level as below Harmonic Current EN61000-3-2 Class A ESD EN61000-4-2 3 A Radiated EN61000-4-3 3 A EFT EN61000-4-4 3 A Surges EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 3 A Magnetic Field EN61000-4-8 3 Low Voltage PSU EMC EN61000-4-11 Dips and Interruptions EN60601-1-2 6 Notes & Conditions A Dip: 30% 500 ms A Dip: 60% 200 ms B Dip: 80% 5000 ms A Dip: 100% 5000 ms B Dip: 30% 25 AC Cycles A 230 VAC 100% load, 100 VAC 80% load Dip: 60% 5 AC Cycles A 230 VAC 100% load, 100 VAC 80% load Dip: 100% 0.5 AC Cycles A Int.: >95% 5000 ms B xppower.com Xxxxxxxxxx Electromagnetic Compatibility - Emissions Phenomenon Standard Test Level EN55011/22 Class B Radiated EN55011/22 Class B Voltage Fluctuations EN61000-3-3 Conducted Criteria Notes & Conditions Safety Agency Approvals Safety Agency Safety Standard CB Report Certificate # US/16502/UL EC60950-1:2005 Ed 2 Category Information Technology UL UL File # E139109-A48-UL UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2 Information Technology TUV TUV Certificate # Z1A 11 02 57396 094, EN60950-1:2006 Information Technology Denan Japan PSE Certificate CE LVD Safety Agency Safety Standard Category CB Report Certificate #US/17220/UL, IEC60601-1 Ed 3 Including Risk Management Medical UL UL File # E146893-V1-S10, ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08 Medical TUV TUV Certificate # B11 07 57396 104, EN60601-1:2006 Medical Primary to Secondary 2 x MOPP (Means of Patient Protection) Primary to Earth 1 x MOPP (Means of Patient Protection) Secondary to Earth 1 x MOPP (Means of Patient Protection) Equipment Protection Class Safety Standard Notes & Conditions IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 2 See safety agency conditions of acceptibility for details Means of Protection Class I & Class II Category IEC60601-1 Ed 3 Environmental Legislation Authority Location Date EISA US 2007 CEC Notes & Conditions California, US 2008 Energy Star US 2008 Level V ErP Directive Europe 2011 Regulation No. 278/2009 7 xppower.com Xxxxxxxxxx Details Mechanical Weight: 1.1 lbs (500 g) Dimensions shown in inches (mm). 7.87 (200.0) 0.193 (4.9) 35.43 (900.0) 0.79 (Ø20.0) 3.15 (80.0) 1.41 (36.0) 5.12 (130.0) 1.61 (41.0) 3.94 (100.3) 2.02 (51.5) 1.58 (40.3) 6.81 (173.0) Shell Optional Input Connector Retention (-A) Standard (Class I) C2 Models (Class II) C2-8 Models (Class II) 1.40 (35.7) 2 4 1 3 Output Connector equivalent to KPPX-4P (Non Locking) IEC 320-C14 IEC 320-C18 IEC 320-C8 Pin 1 Pin 2 Pin 3 Pin 4 Outer Shell Output + Output + Return Return GND* Outer Shell C2 Models Floating * Functional earth. 8 29-Sept-14 AHM250 Series GREEN POWER • Medical & IT Safety Approvals • Energy Star Level V • CEC 2008 & EISA 2007 Compliant • IP22 Environmental Rating • Compact Format 8.60” x 3.50” x 1.46” • <0.5 W Standby Power • 250 W - Convection Cooled Ratings • IEC Input Cable Retention (Optional) • 0 ºC to +60 ºC Operation • Very Low Earth Leakage Current • 3 Year Warranty The AHM250 series of medical external power supplies is fully approved to international medical safety standards. It has been designed with very high efficiency and low standby power, enabling it to meet the latest envirnomental legislation. The unit has a fully sealed enclosure complying with IP22 and a smooth surface finish making it easier to wipe down in a clinical setting. With both medical & IT approvals the product is suitable for hospital, home healthcare, portable medial device applications and a wide range of IT applications. xppower.com Models and Ratings - Convection-cooled Output Power 210 W 220 W 240 W 250 W 250 W Output Voltage V1 12.0 VDC 15.0 VDC 19.0 VDC 24.0 VDC 48.0 VDC Max Output Current 17.50 A 14.66 A 12.63 A 10.41 A 5.21 A Model Number AHM250PS12T AHM250PS15T AHM250PS19T AHM250PS24T AHM250PS48T Notes: 1. For optional input connector retention clip, add suffix ‘-A’ to the model number e.g. AHM250PS24T-A. 2. For 6 pin DIN connector, remove ‘T’ from the end of the model number e.g. AHM250PS24 (DIN connector for medical applications only). Input Characteristics Characteristic Input Voltage - Operating Input Frequency Power Factor Input Current - No Load Input Current - Full Load Inrush Current No Load Input Power Earth Leakage Current Input Protection Minimum 80 47 Typical Maximum 115/230 264 50/60 63 >0.9 0.09/0.10 2.3/1.2 60-80 120 0.3/0.35 0.5 60/120 200 0.4/0.8 T6.3A/250 V internal fuse in both lines Units VAC Hz A A A W μA mA Notes & Conditions Derate <100 VAC (see fig. 1) EN61000-3-2 class A & D compliant & Energy Star Compliant 115/230 VAC 115/230 VAC 230 VAC cold start, 25 şC 115/230 VAC 115 V 60 Hz/230 V 50 Hz (Typ.), 264 VAC/60 Hz (Max.) 115/230 VAC/400 Hz Output Characteristics Characteristic Output Voltage - V1 Minimum Typical 12 Maximum Units Notes & Conditions 48 VDC See Models and Ratings table Output Voltage Adjustment Minimum Load % 0 Start Up Delay 300/200 ms Hold Up Time 15 ms 115/230 VAC full load (see fig.2) 115/230 VAC full load (see fig.3) Drift ±0.2 % After 20 min warm up Line Regulation ±0.5 % 90-264 VAC (50% load) Load Regulation ±4 % 0f50g100% load. Transient Response - V1 5 % Recovery within 1% in less than 500 μs for a 50-75% and 7550% load step 1.5 % pk-pk Over/Undershoot - V1 3 Ripple & Noise <1 % 125 Overvoltage Protection Overload Protection % Temperature Coefficient Overtemperature Protection 20 MHz bandwidth with external circuit (see fig.4-7) Vnom, Recycle AC to reset 13.2 18 AHM250PS12 16.5 22 AHM250PS15 21.0 28 26.4 33 52.8 59 115.0 175 21.0 29.8 17.6 26.3 15.2 21.5 11.5 17.7 AHM250PS24 5.7 8.9 AHM250PS48 VDC AHM250PS19 AHM250PS24 AHM250PS48 % I nom, Auto reset AHM250PS12 AHM250PS15 A Short Circuit Protection 2 No user adjustment A AHM250PS19 Continuous, trip & restart (hiccup mode) 0.05 %/˚C °C Connected to transformer. Auto reset. xppower.com Derating Curve Figure 1 100 Output Power (%) 90 80 70 60 50 40 80 90 100 110 240 250 264 Start Up Delay From AC Turn On Figure 2 Start up example from AC turn on (230 VAC, 210 ms) Hold Up Time From Loss of AC Figure 3 Hold up example at 250 W load with 230 VAC input (15 ms) 3 xppower.com Ripple & Noise Figure 4 AHM250PS12 Ripple & noise example at 210 W load with 230 VAC input (50 mV) Figure 5 AHM250PS24 Ripple & noise example at 250 W load with 230 VAC input (100 mV) Figure 6 AHM250PS48 Ripple & noise example at 250 W load with 230 VAC input (180 mV) Figure 7 Ripple & noise measurement circuit 10 µF Electrolytic 4 0.1 µF Ceramic xppower.com Xxxxxxxxxx General Specifications Characteristic Efficiency Isolation: Input to Output Input to Ground Output to Ground Minimum Typical 92 Maximum 4000 1500 500 40 80 Switching Frequency Units % VAC VAC VAC 220 150 5.7 Power Density Mean Time Between Failure Weight 151 2.1 (1000) Notes & Conditions Full load (see fig.8-10) kHz PFC stage DC-DC stage W/in3 kHrs lb (g) MIL-HDBK-217F, Notice 2 +25 °C GB Average Active Efficiency GREEN POWER Average Active Efficiency 115 V / 60 Hz 230 VAC / 50 Hz 89.16 89.67 90.05 90.71 89.65 90.76 91.85 92.20 91.32 92.46 Characteristic AHM250PS12 AHM250PS15 AHM250PS19 AHM250PS24 AHM250PS48 Units Notes & Conditions % As per Energy Star Level V test procedure Efficiency Versus Load 100% 90% Efficiency 80% 70% 60% 50% 40% 30% 20% 10% 0% 10 20 30 40 50 60 70 80 90 100 Load (%) Figure 8 - AHM250PS12 100% 100% 90% 90% 80% 80% 70% 70% 60% 60% 50% 50% 40% 40% 30% 30% 20% 20% 10% 10% 0% 0% 10 20 30 40 50 60 70 80 90 100 10 Load (%) 115Vac input 20 30 40 50 60 70 80 90 100 Load (%) Figure 10 - AHM250PS48 Figure 9 - AHM250PS24 230Vac input 5 xppower.com Xxxxxxxxxx Environmental Characteristic Minimum Operating Temperature Typical Maximum 0 Units +60 °C 86 71 °C Case Temperature (IEC60601 3rd Edition) Notes & Conditions Derate linearly to 60% load at 60 °C from +40 °C. (See fig.11) 100% load with TAMB +40 °C 80% Load, with TAMB +40 °C 60 Storage Temperature 60% Load Maximum, with TAMB +40 °C 48 °C -40 +85 °C 5% Load Maximum, with TAMB +40 °C 5 95 %RH 3000 m Cooling Convection cooled, see fig.11 Humidity Operating Altitude Ingress Protection Non-condensing IP22 Shock 3 x 30 g/11 ms shocks in both +ve & -ve directions along the 3 orthogonal axis, total 18 shocks. Vibration Three axis 5-500 Hz at 2 g x 10 sweeps Derating Curve 100% Output Power (%) Figure 11 60% 0 10 20 Ambient Temperature (ºC) 60 40 Electromagnetic Compatibility - Immunity Phenomenon Standard Test Level Criteria EN61204-3 High severity level as below Harmonic Current EN61000-3-2 Class A ESD EN61000-4-2 3 A Radiated EN61000-4-3 3 A EFT EN61000-4-4 3 A Surges EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 3 A Magnetic Field EN61000-4-8 3 A Low Voltage PSU EMC EN55024 (EN61000-4-11) Dips and Interruptions EN60601-1-2 6 Notes & Conditions Dip: 30% 500 ms Dip: >95% 10 ms A A Int: >95% 5000 ms B Dip: 30% 500 ms A 230 VAC 100% load, 100 VAC 60% load Dip: 60% 100 ms A 230 VAC 100% load, 100 VAC 15% load Dip: >95% 10 ms A Int.: >95% 5000 ms B xppower.com Xxxxxxxxxx Electromagnetic Compatibility - Emissions Phenomenon Conducted Radiated Voltage Fluctuations Standard Test Level EN55011/22 Class B EN55011/22 Class B Criteria Notes & Conditions EN61000-3-3 Safety Agency Approvals Safety Agency Safety Standard Category CB Report UL TBA IEC60950-1:2005 Ed 2 Information Technology UL UL File TBA UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2 Information Technology TUV TUV Certificate # TBA, EN60950-1:2006 Information Technology Denan Japan PSE Certificate CE LVD Safety Agency Safety Standard Category CB Report Certificate #US/18020/UL, IEC60601-1 Ed 3 Including Risk Management Medical UL UL File # E146893, ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08 Medical TUV TUV Certificate # Z11 11 57396 116, EN60601-1:2006 Medical Primary to Secondary 2 x MOPP (Means of Patient Protection) Means of Protection Category Primary to Earth 1 x MOPP (Means of Patient Protection) Secondary to Earth 1 x MOPP (Means of Patient Protection) Equipment Protection Class Safety Standard Notes & Conditions IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 3 See safety agency conditions of acceptibility for details Class I IEC60601-1 Ed 3 Environmental Legislation Authority Location Date EISA US 2007 CEC Notes & Conditions California, US 2008 Energy Star US 2008 Level V ErP Directive Europe 2011 Regulation No. 278/2009 7 xppower.com Xxxxxxxxxx Details Mechanical Weight: 2.2 lbs (1000 g) Dimensions shown in inches (mm). 0.2 (5.0) Standard Molex 6 pin Connector 8.8 (223.0) 8.58 (218.0) 35.43 (900.0) 0.79 (Ø 20.0) 3.484 (88.50) 1.417 (36.0) Optional 6 pin DIN connector shown (for medical applications only) IEC 320-C14 0.79 (Ø 20.0) 1.457 (37.0) 0.063 (1.60) 4.134 (105.0) 1.417 (36.0) 7.41 (188.40) 2.37 (60.20) 1.97 (50.20) 5.12 (130.20) Optional Input Connector Retention (-A) 5 4 6 1.40 (35.7) OUTPUT CONNECTOR 1 2 3 Shell IEC 320-C14 1 2 3 6 5 4 Pin No. Molex Type(3) DIN Type(4) Pin 1 Return Output + Pin 2 Return Return Pin 3 Return Return Pin 4 Output + Return Pin 5 Output + Output + Pin 6 Ouput + Ouput + Outer Shell GND* Notes 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight 2.2 lbs (1000 g). 3. Molex part no. 50-36-1672 mates with Molex part no. 39-30-1062 or equivalent. 4. Equivalent to DIN45322 (6 pin at 60°) Male. * Functional earth. 8 28-Oct-13