GENERAL 01765

Industrial-Grade Cable
Mining
Super Vu-Tron® Welding Cable
90ºC 600 Volt UL /CSA RHH/RHW
Product Construction:
Conductor:
• 6 AWG through 4/0 AWG fully annealed
stranded bare copper per ASTM B-172 Class M
Jacket:
• Super Vu-Tron®, orange
• Temperature range: -50ºC to +90ºC
Jacket Marking:
SUPER VU-TRON® WELDING CABLE—UL/CSA—CLASS M—34 AWG STRANDING
•#6 - #1 AWG: CAROL SUPER VU-TRON®
WELDING CABLE–EXTRA FLEXIBLE (UL) 600
VOLT (-50°C to +90°C) OIL RESISTANT
P-123-141 MSHA (SIZE) CSA 90°C ARC
WELDING CABLE FT-1
•1/0 - 4/0 AWG: CAROL SUPER VU-TRON®
WELDING CABLE (SIZE) EXTRA FLEXIBLE
(UL) 600 VOLT (-50°C to +90°C) OIL
RESISTANT P-123-141 MSHA CSA 90°C
ARC WELDING CABLE FT-1 TYPE RHH OR
RHW (UL) 600V FOR CT USE
Applications:
• Secondary voltage resistance welding leads
• Power supply applications not exceeding
600 volts AC
• Sizes 1/0 and larger for permanent wiring
in conduit or tray of 600V power supplies,
hoists, cranes or other applications where
flexible power leads must be installed in
conduit, raceways or trays
Features:
• UL Listed
• CSA Certified
• Excellent flexibility to last longer in flex
applications
• Abrasion-resistant
• Resists oils and solvents
• Rated -50ºC for use in cold environments
• Weather-resistant
• Ozone-resistant
• Safety-colored for high visibility
• Assured longer service life, saving money
in replacement costs, maintenance cost
and downtime
• MSHA approved for flame resistance
• Sunlight-resistant
Industry Approvals:
• UL Listed
• CSA Certified
• MSHA Approved
• Meets UL Vertical Flame Test per UL 854
• RoHS Compliant
Packaging:
• 250' (76.2 m), 500' (152.4 m), and 1000'
(304.8 m) reels
• Other put-ups available on special order
Suggested Ampacities:
For 600 Volt In-Line Applications
AWG
4/0
3/0
2/0
1/0
AMPERES
405
350
300
260
AWG
1
2
4
6
AMPERES
220
190
140
105
Per Standards: ICEA S-19-81 NEMA WC-3 Part 8,
Appendix J Ampacities for portable cable in accordance
with NEC Table 400.5(B).
May not be suitable for all installations per National
Electrical Code ®.
28
mm
APPROX.
NET WT.
LBS/M'(S)
STD.
CTN.
0.370
9.40
125
250'
0.415
10.54
191
250'
1666/34
0.475
12.07
259
250'
2090/34
0.530
13.46
331
250'
1/0
2640/34
0.575
14.61
401
250'
2/0
3300/34
0.630
16.00
511
250'
01762†
3/0
4180/34
0.700
17.78
615
250'
01761†
4/0
5225/34
0.800
20.32
844
250'
CATALOG
NUMBER
COND. SIZE
(AWG)
01768
01767
NOMINAL O.D.
CONDUCTOR
STRAND
INCHES
6
660/34
4
1045/34
01766
2
01765
1
01764†
01763†
Actual shipping weight may vary.
†Type RHH/RHW - 600V for CT use.
(S)
WELDING CABLE AMPACITIES
SINGLE CONDUCTOR
Required Cable Sizes: For Welding Cable Application
length in feet for total circuit for secondary voltages only – do not use this table for 600 Volt in-line applications
AMPS
100
150
200
250
300
350
400
450
500
550
600
100'
4
4
2
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
150'
4
2
1
1/0
2/0
3/0
3/0
4/0
4/0
4/0
200'
2
1
1/0
2/0
3/0
4/0
250'
2
1/0
2/0
3/0
4/0
300'
1
2/0
3/0
4/0
350'
1/0
3/0
4/0
400'
1/0
3/0
4/0
REQUIRED CABLE SIZES SHOWN IN AWG NUMBERS
The total circuit length includes both welding and ground leads (Based on 4-volt drop) 60% duty cycle.
These values for current-carrying capacity are based on a copper temperature of 60°C (140°F), an ambient temperature of
40°C (104°F) and yield load factors of from approximately 32% for the No. 2 AWG cable to approximately 23% for the
No. 3/0 AWG cable, and higher for the smaller sizes. The sizes of cables generally used range from No. 2 AWG to
No. 3/0 AWG. In actual service, the load factor may be much higher that indicated without overheating the cable as the
ambient temperature will generally be substantially lower than 40°C.
Mining
Industrial-Grade Cable
Super Vu-Tron® EPR/CPE Diesel Locomotive Cable
90ºC 2000 Volt DLO, UL RHH/RHW 600 Volts CSA R90 1000 Volt
Product Construction:
Conductor:
• 14 AWG through 1111.1 kcmil stranded
tinned annealed copper per AAR 589
Insulation:
• Premium-grade 90ºC EP
Jacket:
• Chlorinated Polyethylene (CPE), black
14 AWG - 1111.1 kcmil DLO - 2000 VOLT
Jacket Marking:
CATALOG
NUMBER
COND.
SIZE
(AWG/
kcmil)
COND.
STRAND
INCHES
mm
INCHES
mm
81914
14
19/0.0147
0.045
1.14
0.21
5.44
25
35
34
81912
12
19/0.0185
0.047
1.19
0.24
6.10
30
40
45
81910
10
27/24
0.045
1.14
0.26
6.60
40
55
60
81908
8
37/24
0.060
1.52
0.34
8.64
55
80
95
81906
6
61/24
0.060
1.52
0.40
10.16
75
105
145
81904
4
105/24
0.060
1.52
0.46
11.68
95
140
205
81902
2
154/24
0.060
1.52
0.52
13.21
130
190
295
81901
1
224/24
0.080
2.03
0.65
16.51
150
220
440
81911
1/0
280/24
0.080
2.03
0.69
17.53
170
260
515
• SIZES 14 THROUGH 1 AWG - CAROL
SUPER VU-TRON® (SIZE) (STRANDING)
90°C DLO 2000 VOLTS P-7K-123040
MSHA CSA R90 1000V (UL) RHH or RHW
600 VOLTS
• SIZES 1/0 THROUGH 646.4 - CAROL
SUPER VU-TRON® (SIZE) 90°C DLO
2000 VOLTS P-7K-123040 MSHA CSA R90
1000V (-40°C) FT-1 (UL) RHH or RHW 600
VOLTS SUNLIGHT RESISTANT FOR CT
USE
NOTE: 535.3 AND 646.4 kcmil printed (UL) RHH OR RHW 2000 VOLTS
• SIZES 777.7 THROUGH 1111.1 kcmil CAROL SUPER VU-TRON® C(UL) TYPE
RHW-2 2KV VW-1 FOR CT USE TYPE DLO
2000V 90°C P-102 MSHA
81920
2/0
329/24
0.080
2.03
0.73
18.54
195
300
580
Applications:
81930
3/0
456/24
0.080
2.03
0.81
20.57
225
350
770
NOM. INS.
THICKNESS
NOMINAL O.D.
CURRENT
AMPS
(1)
(2)
APPROX.
NET WEIGHT
LBS/MFT(S)
81940
4/0
551/24
0.080
2.03
0.87
22.10
260
405
930
81926
262.6
650/24
0.095
2.41
1.00
25.40
296
467
1130
81931
313.3
777/24
0.095
2.41
1.06
26.92
326
522
1295
81937
373.7
925/24
0.095
2.41
1.10
27.94
362
591
1545
81944
444.4
1110/24
0.095
2.41
1.23
31.24
400
652
1820
81953
535.3
1332/24
0.120
3.05
1.34
34.04
445
728
2195
81964
646.4
1609/24
0.120
3.05
1.45
36.83
493
815
2560
81977
777.7
1924/24
0.120
3.05
1.50
38.10
546
904
3050
81929* 929.2
2299/24
0.120
3.05
1.67
42.42
602
1014
3625
81999 1111.1
2745/24
0.140
3.56
1.84
46.74
635
1115
4354
Dimensions and weights are nominal; subject to industry tolerances.
(1)
Ampacities based on 90°C conductor and 30°C ambient temperature based on the National Electrical Code® for not more
than three current-carrying conductors in raceway, cable or earth.
(2)
Ampacities based on single-conductor in free air, 90°C conductor temperature and an ambient air temperature of 30°C, in
accordance with National Electrical Code® (NEC).
(S)
Actual shipping weight may vary.
* Non-stock item
• Diesel electric locomotives
• Telecom power supply
• Mining and earth-moving equipment
• Shipyards
• Motor leads
• Where flexible power leads must be
installed in conduit or raceways
Features:
• 90ºC temperature rating
• Excellent impact and abrasion resistance
• Resists oils, acids, alkalies, heat, flame
• Flexible tinned copper stranding
• FT4 upon request
• Sunlight-resistant
Industry Approvals:
• UL Listed
• Accepted for listing as flame-resistant
by MSHA
• CSA R90
• RoHS Compliant
Packaging:
• Lengths cut to order
29