Industrial-Grade Cable Mining Super Vu-Tron® Welding Cable 90ºC 600 Volt UL /CSA RHH/RHW Product Construction: Conductor: • 6 AWG through 4/0 AWG fully annealed stranded bare copper per ASTM B-172 Class M Jacket: • Super Vu-Tron®, orange • Temperature range: -50ºC to +90ºC Jacket Marking: SUPER VU-TRON® WELDING CABLE—UL/CSA—CLASS M—34 AWG STRANDING •#6 - #1 AWG: CAROL SUPER VU-TRON® WELDING CABLE–EXTRA FLEXIBLE (UL) 600 VOLT (-50°C to +90°C) OIL RESISTANT P-123-141 MSHA (SIZE) CSA 90°C ARC WELDING CABLE FT-1 •1/0 - 4/0 AWG: CAROL SUPER VU-TRON® WELDING CABLE (SIZE) EXTRA FLEXIBLE (UL) 600 VOLT (-50°C to +90°C) OIL RESISTANT P-123-141 MSHA CSA 90°C ARC WELDING CABLE FT-1 TYPE RHH OR RHW (UL) 600V FOR CT USE Applications: • Secondary voltage resistance welding leads • Power supply applications not exceeding 600 volts AC • Sizes 1/0 and larger for permanent wiring in conduit or tray of 600V power supplies, hoists, cranes or other applications where flexible power leads must be installed in conduit, raceways or trays Features: • UL Listed • CSA Certified • Excellent flexibility to last longer in flex applications • Abrasion-resistant • Resists oils and solvents • Rated -50ºC for use in cold environments • Weather-resistant • Ozone-resistant • Safety-colored for high visibility • Assured longer service life, saving money in replacement costs, maintenance cost and downtime • MSHA approved for flame resistance • Sunlight-resistant Industry Approvals: • UL Listed • CSA Certified • MSHA Approved • Meets UL Vertical Flame Test per UL 854 • RoHS Compliant Packaging: • 250' (76.2 m), 500' (152.4 m), and 1000' (304.8 m) reels • Other put-ups available on special order Suggested Ampacities: For 600 Volt In-Line Applications AWG 4/0 3/0 2/0 1/0 AMPERES 405 350 300 260 AWG 1 2 4 6 AMPERES 220 190 140 105 Per Standards: ICEA S-19-81 NEMA WC-3 Part 8, Appendix J Ampacities for portable cable in accordance with NEC Table 400.5(B). May not be suitable for all installations per National Electrical Code ®. 28 mm APPROX. NET WT. LBS/M'(S) STD. CTN. 0.370 9.40 125 250' 0.415 10.54 191 250' 1666/34 0.475 12.07 259 250' 2090/34 0.530 13.46 331 250' 1/0 2640/34 0.575 14.61 401 250' 2/0 3300/34 0.630 16.00 511 250' 01762† 3/0 4180/34 0.700 17.78 615 250' 01761† 4/0 5225/34 0.800 20.32 844 250' CATALOG NUMBER COND. SIZE (AWG) 01768 01767 NOMINAL O.D. CONDUCTOR STRAND INCHES 6 660/34 4 1045/34 01766 2 01765 1 01764† 01763† Actual shipping weight may vary. †Type RHH/RHW - 600V for CT use. (S) WELDING CABLE AMPACITIES SINGLE CONDUCTOR Required Cable Sizes: For Welding Cable Application length in feet for total circuit for secondary voltages only – do not use this table for 600 Volt in-line applications AMPS 100 150 200 250 300 350 400 450 500 550 600 100' 4 4 2 1 1/0 1/0 2/0 2/0 3/0 3/0 4/0 150' 4 2 1 1/0 2/0 3/0 3/0 4/0 4/0 4/0 200' 2 1 1/0 2/0 3/0 4/0 250' 2 1/0 2/0 3/0 4/0 300' 1 2/0 3/0 4/0 350' 1/0 3/0 4/0 400' 1/0 3/0 4/0 REQUIRED CABLE SIZES SHOWN IN AWG NUMBERS The total circuit length includes both welding and ground leads (Based on 4-volt drop) 60% duty cycle. These values for current-carrying capacity are based on a copper temperature of 60°C (140°F), an ambient temperature of 40°C (104°F) and yield load factors of from approximately 32% for the No. 2 AWG cable to approximately 23% for the No. 3/0 AWG cable, and higher for the smaller sizes. The sizes of cables generally used range from No. 2 AWG to No. 3/0 AWG. In actual service, the load factor may be much higher that indicated without overheating the cable as the ambient temperature will generally be substantially lower than 40°C. Mining Industrial-Grade Cable Super Vu-Tron® EPR/CPE Diesel Locomotive Cable 90ºC 2000 Volt DLO, UL RHH/RHW 600 Volts CSA R90 1000 Volt Product Construction: Conductor: • 14 AWG through 1111.1 kcmil stranded tinned annealed copper per AAR 589 Insulation: • Premium-grade 90ºC EP Jacket: • Chlorinated Polyethylene (CPE), black 14 AWG - 1111.1 kcmil DLO - 2000 VOLT Jacket Marking: CATALOG NUMBER COND. SIZE (AWG/ kcmil) COND. STRAND INCHES mm INCHES mm 81914 14 19/0.0147 0.045 1.14 0.21 5.44 25 35 34 81912 12 19/0.0185 0.047 1.19 0.24 6.10 30 40 45 81910 10 27/24 0.045 1.14 0.26 6.60 40 55 60 81908 8 37/24 0.060 1.52 0.34 8.64 55 80 95 81906 6 61/24 0.060 1.52 0.40 10.16 75 105 145 81904 4 105/24 0.060 1.52 0.46 11.68 95 140 205 81902 2 154/24 0.060 1.52 0.52 13.21 130 190 295 81901 1 224/24 0.080 2.03 0.65 16.51 150 220 440 81911 1/0 280/24 0.080 2.03 0.69 17.53 170 260 515 • SIZES 14 THROUGH 1 AWG - CAROL SUPER VU-TRON® (SIZE) (STRANDING) 90°C DLO 2000 VOLTS P-7K-123040 MSHA CSA R90 1000V (UL) RHH or RHW 600 VOLTS • SIZES 1/0 THROUGH 646.4 - CAROL SUPER VU-TRON® (SIZE) 90°C DLO 2000 VOLTS P-7K-123040 MSHA CSA R90 1000V (-40°C) FT-1 (UL) RHH or RHW 600 VOLTS SUNLIGHT RESISTANT FOR CT USE NOTE: 535.3 AND 646.4 kcmil printed (UL) RHH OR RHW 2000 VOLTS • SIZES 777.7 THROUGH 1111.1 kcmil CAROL SUPER VU-TRON® C(UL) TYPE RHW-2 2KV VW-1 FOR CT USE TYPE DLO 2000V 90°C P-102 MSHA 81920 2/0 329/24 0.080 2.03 0.73 18.54 195 300 580 Applications: 81930 3/0 456/24 0.080 2.03 0.81 20.57 225 350 770 NOM. INS. THICKNESS NOMINAL O.D. CURRENT AMPS (1) (2) APPROX. NET WEIGHT LBS/MFT(S) 81940 4/0 551/24 0.080 2.03 0.87 22.10 260 405 930 81926 262.6 650/24 0.095 2.41 1.00 25.40 296 467 1130 81931 313.3 777/24 0.095 2.41 1.06 26.92 326 522 1295 81937 373.7 925/24 0.095 2.41 1.10 27.94 362 591 1545 81944 444.4 1110/24 0.095 2.41 1.23 31.24 400 652 1820 81953 535.3 1332/24 0.120 3.05 1.34 34.04 445 728 2195 81964 646.4 1609/24 0.120 3.05 1.45 36.83 493 815 2560 81977 777.7 1924/24 0.120 3.05 1.50 38.10 546 904 3050 81929* 929.2 2299/24 0.120 3.05 1.67 42.42 602 1014 3625 81999 1111.1 2745/24 0.140 3.56 1.84 46.74 635 1115 4354 Dimensions and weights are nominal; subject to industry tolerances. (1) Ampacities based on 90°C conductor and 30°C ambient temperature based on the National Electrical Code® for not more than three current-carrying conductors in raceway, cable or earth. (2) Ampacities based on single-conductor in free air, 90°C conductor temperature and an ambient air temperature of 30°C, in accordance with National Electrical Code® (NEC). (S) Actual shipping weight may vary. * Non-stock item • Diesel electric locomotives • Telecom power supply • Mining and earth-moving equipment • Shipyards • Motor leads • Where flexible power leads must be installed in conduit or raceways Features: • 90ºC temperature rating • Excellent impact and abrasion resistance • Resists oils, acids, alkalies, heat, flame • Flexible tinned copper stranding • FT4 upon request • Sunlight-resistant Industry Approvals: • UL Listed • Accepted for listing as flame-resistant by MSHA • CSA R90 • RoHS Compliant Packaging: • Lengths cut to order 29