TI1 CDCVF855PWRG4 2.5-v phase-locked-loop clock driver Datasheet

CDCVF855
www.ti.com
SCAS839A – APRIL 2007 – REVISED MAY 2007
2.5-V PHASE-LOCKED-LOOP CLOCK DRIVER
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
•
DESCRIPTION
Spread-Spectrum Clock Compatible
Operating Frequency: 60 MHz to 220 MHz
Low Jitter (Cycle-Cycle): ±60 ps (±40 ps at 200
MHz)
Low Static Phase Offset: ±50 ps
Low Jitter (Period): ±60 ps (±30 ps at 200 MHz)
1-to-4 Differential Clock Distribution (SSTL2)
Best in Class for VOX = VDD/2 ±0.1 V
Operates From Dual 2.6-V or 2.5-V Supplies
Available in a 28-Pin TSSOP Package
Consumes < 100-µA Quiescent Current
External Feedback Pins (FBIN, FBIN) Are Used
to Synchronize the Outputs to the Input
Clocks
Meets/Exceeds JEDEC Standard (JESD82-1)
For DDRI-200/266/333 Specification
Meets/Exceeds Proposed DDRI-400
Specification (JESD82-1A)
Enters Low-Power Mode When No CLK Input
Signal Is Applied or PWRDWN Is Low
APPLICATIONS
•
•
DDR Memory Modules (DDR400/333/266/200)
Zero-Delay Fan-Out Buffer
The CDCVF855 is a high-performance, low-skew,
low-jitter, zero-delay buffer that distributes a
differential clock input pair (CLK, CLK) to 4
differential pairs of clock outputs (Y[0:3], Y[0:3]) and
one differential pair of feedback clock outputs
(FBOUT, FBOUT). The clock outputs are controlled
by the clock inputs (CLK, CLK), the feedback clocks
(FBIN, FBIN), and the analog power input (AVDD).
When PWRDWN is high, the outputs switch in phase
and frequency with CLK. When PWRDWN is low, all
outputs are disabled to a high-impedance state
(3-state) and the PLL is shut down (low-power
mode). The device also enters this low-power mode
when the input frequency falls below a suggested
detection frequency that is below 20 MHz (typical 10
MHz). An input frequency-detection circuit detects
the low-frequency condition and, after applying a
>20-MHz input signal, this detection circuit turns the
PLL on and enables the outputs.
When AVDD is strapped low, the PLL is turned off
and bypassed for test purposes. The CDCVF855 is
also able to track spread-spectrum clocking for
reduced EMI.
Because the CDCVF855 is based on PLL circuitry, it
requires a stabilization time to achieve phase-lock of
the PLL. This stabilization time is required following
power up. The CDCVF855 is characterized for both
commercial and industrial temperature ranges.
AVAILABLE OPTIONS
TA
TSSOP (PW)
–40°C to 85°C
CDCVF855PW
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2007, Texas Instruments Incorporated
CDCVF855
www.ti.com
SCAS839A – APRIL 2007 – REVISED MAY 2007
FUNCTION TABLE
(Select Functions)
INPUTS
OUTPUTS
PLL
AVDD
PWRDWN
CLK
CLK
Y[0:3]
Y[0:3]
FBOUT
FBOUT
GND
H
L
H
L
H
L
H
Bypassed/off
GND
H
H
L
H
L
H
L
Bypassed/off
X
L
L
H
Z
Z
Z
Z
Off
X
L
H
L
Z
Z
Z
Z
Off
2.5 V (nom)
H
L
H
L
H
L
H
On
2.5 V (nom)
H
H
L
H
L
H
L
On
2.5 V (nom)
X
<20 MHz
<20 MHz
Z
Z
Z
Z
Off
PW PACKAGE
(TOP VIEW)
GND
Y0
Y0
VDDQ
GND
CLK
CLK
VDDQ
AVDD
AGND
VDDQ
Y1
Y1
GND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
28
27
26
25
24
23
22
21
20
19
18
17
16
15
GND
Y3
Y3
VDDQ
PWRDWN
FBIN
FBIN
VDDQ
FBOUT
FBOUT
VDDQ
Y2
Y2
GND
P0043-02
FUNCTIONAL BLOCK DIAGRAM
3
2
PWRDWN
AVDD
12
24
9
Powerdown
and Test
Logic
13
17
16
26
27
CLK
CLK
FBIN
FBIN
19
6
7
23
20
Y0
Y0
Y1
Y1
Y2
Y2
Y3
Y3
FBOUT
FBOUT
PLL
22
B0196-02
2
Submit Documentation Feedback
CDCVF855
www.ti.com
SCAS839A – APRIL 2007 – REVISED MAY 2007
Table 2. TERMINAL FUNCTIONS
TERMINAL
NAME
NO.
I/O
DESCRIPTION
AGND
10
–
Ground for 2.5-V analog supply
AVDD
9
–
2.5-V analog supply
CLK, CLK
6, 7
I
Differential clock input
FBIN, FBIN
22, 23
I
Feedback differential clock input
FBOUT, FBOUT
19, 20
O
Feedback differential clock output
GND
1, 5, 14, 15, 28
–
Ground
PWRDWN
24
I
Output enable for Y and Y
VDDQ
4, 8, 11, 18, 21, 25
–
2.5-V supply
Y0, Y0
2, 3
O
Buffered output copies of input clock, CLK, CLK
Y1, Y1
12, 13
O
Buffered output copies of input clock, CLK, CLK
Y2, Y2
16, 17
O
Buffered output copies of input clock, CLK, CLK
Y3, Y3
26, 27
O
Buffered output copies of input clock, CLK, CLK
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1)
VDDQ, AVDD
Supply voltage range
VI
Input voltage range (2) (3)
VO
Output voltage range (2) (3)
IIK
Input clamp current
VI < 0 or VI > VDDQ
±50 mA
IOK
Output clamp current
VO < 0 or VO > VDDQ
±50 mA
IO
Continuous output current
VO = 0 to VDDQ
IDDS
Continuous current to GND or VDDQ
Tstg
Storage temperature range
(1)
(2)
(3)
0.5 V to 3.6 V
–0.5 V to VDDQ + 0.5 V
–0.5 V to VDDQ + 0.5 V
±50 mA
±100 mA
–65°C to 150°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
The input and output negative voltage ratings may be exceeded if the input and output clamp current ratings are observed.
This value is limited to 3.6 V maximum.
THERMAL CHARACTERISTICS
RθJA for TSSOP Package (1)
(1)
Airflow
High K
0 ft/min (0 m/min)
94.4°C/W
150 ft/min (45.72 m/min)
82.8°C/W
The package thermal impedance is calculated in accordance with JESD 51.
Submit Documentation Feedback
3
CDCVF855
www.ti.com
SCAS839A – APRIL 2007 – REVISED MAY 2007
RECOMMENDED OPERATING CONDITIONS
MIN
VDDQ PC1600 – PC3200
Supply voltage
VIL
Low-level input voltage
VIH
High-level input voltage
AVDD
MAX
2.3
2.7
VDDQ – 0.12
2.7
CLK, CLK, FBIN, FBIN
VDDQ/2 – 0.18
PWRDWN
–0.3
CLK, CLK, FBIN, FBIN
DC
CLK, FBIN
Differential input signal voltage (2)
AC
CLK, FBIN
0.7
VDDQ/2 + 0.18
PWRDWN
DC input signal voltage (1)
VID
NOM
1.7
VDDQ + 0.3
–0.3
VDDQ + 0.3
VDDQ = 2.3 V – 2.7V
0.36
VDDQ + 0.6
VDDQ = 2.425 V – 2.7 V
0.25
VDDQ + 0.6
0.7
VDDQ + 0.6
0.49
VDDQ + 0.6
VDDQ/2 – 0.2
VDDQ/2 + 0.2
VDDQ = 2.3 V – 2.7 V
VDDQ = 2.425 V – 2.7 V
UNIT
V
V
V
V
V
VIX
Input differential pair cross
voltage (3) (4)
IOH
High-level output current
–12
IOL
Low-level output current
12
mA
SR
Input slew rate
1
4
V/ns
TA
Operating free-air temperature
–40
85
°C
(1)
(2)
(3)
(4)
V
mA
The unused inputs must be held high or low to prevent them from floating.
The dc input signal voltage specifies the allowable dc execution of the differential input.
The differential input signal voltage specifies the differential voltage |VTR – VCP| required for switching, where VTR is the true input
level and VCP is the complementary input level.
The differential cross-point voltage is expected to track variations of VCC and is the voltage at which the differential signals must cross.
ELECTRICAL CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
VIK
Input voltage, all inputs
VOH
High-level output voltage
VOL
Low-level output voltage
VOD
Output voltage swing
(2)
MIN
TYP
(1)
VDDQ = 2.3 V, II = –18 mA
VDDQ = min to max, IOH = –1 mA
VDDQ = 2.3 V, IOH = –12 mA
MAX
UNIT
–1.2
V
VDDQ – 0.1
V
1.7
VDDQ = min to max, IOL = 1 mA
0.1
VDDQ = 2.3 V, IOL = 12 mA
0.6
1.1
V
VDDQ – 0.4
V
VDDQ/2 + 0.1
V
(3)
Differential outputs are terminated with 120 Ω,
CL = 14 pF (See Figure 3)
II
Input current
VDDQ = 2.7 V, VI = 0 V to 2.7 V
±10
µA
IOZ
High-impedance-state output
current
VDDQ = 2.7 V, VO = VDDQ or GND
±10
µA
IDDPD
Power-down current on VDDQ +
AVDD
CLK and CLK = 0 MHz; PWRDWN = Low; Σ of
IDD and AIDD
100
µA
AIDD
Supply current on AVDD
CI
Input capacitance
Output differential cross-voltage
VOX
(1)
(2)
(3)
4
TEST CONDITIONS
VDDQ/2 – 0.1
VDDQ/2
20
fO = 170 MHz
6
8
fO = 200 MHz
8
10
2.5
3.5
VDDQ = 2.5 V, VI = VDDQ or GND
2
mA
pF
All typical values are at a nominal VDDQ.
The differential output signal voltage specifies the differential voltage |VTR – VCP|, where VTR is the true output level and VCP is the
complementary output level.
The differential cross-point voltage tracks variations of VDDQ and is the voltage at which the differential signals must cross.
Submit Documentation Feedback
CDCVF855
www.ti.com
SCAS839A – APRIL 2007 – REVISED MAY 2007
ELECTRICAL CHARACTERISTICS (continued)
over recommended operating free-air temperature range (unless otherwise noted)
(1)
MAX
fO = 170 MHz
65
80
fO = 200 MHz
75
90
Differential outputs terminated
with 120 Ω, CL = 0 pF
fO = 170 MHz
110
140
fO = 200 MHz
120
150
Differential outputs terminated
with 120 Ω, CL = 14 pF
fO = 170 MHz
130
160
fO = 200 MHz
140
170
PARAMETER
TEST CONDITIONS
Without load
IDD
Dynamic current on VDDQ
MIN
TYP
UNIT
mA
∆C
Part-to-part input capacitance
variation
VDDQ = 2.5 V, VI = VDDQ or GND
1
pF
CI(∆)
Input capacitance difference
between CLK and CLK, FBIN
and FBIN
VDDQ = 2.5 V, VI = VDDQ or GND
0.25
pF
TIMING REQUIREMENTS
over recommended ranges of supply voltage and operating free-air temperature
PARAMETER
fCLK
MIN
MAX
Operating clock frequency
60
220
Application clock frequency
90
220
40%
60%
Input clock duty cycle
Stabilization time (PLL
mode) (1)
Stabilization time (bypass mode) (2)
(1)
(2)
UNIT
MHz
10
µs
30
ns
The time required for the integrated PLL circuit to obtain phase lock of its feedback signal to its reference signal. For phase lock to be
obtained, a fixed-frequency, fixed-phase reference signal must be present at CLK and VDD must be applied. Until phase lock is obtained,
the specifications for propagation delay, skew, and jitter parameters given in the switching characteristics table are not applicable. This
parameter does not apply for input modulation under SSC application.
A recovery time is required when the device goes from power-down mode into bypass mode (AVDD at GND).
Submit Documentation Feedback
5
CDCVF855
www.ti.com
SCAS839A – APRIL 2007 – REVISED MAY 2007
SWITCHING CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted)
PARAMETER
tPLH (1)
(1)
tPHL
tjit(per) (2)
tjit(cc) (2)
tjit(hper) (2)
TEST CONDITIONS
MIN
High- to low-level propagation delay
time
3.5
ns
Jitter (period), see Figure 7
Jitter (cycle-to-cycle), see Figure 4
Test mode/CLK to any output
100/133/167 MHz
(PC1600/2100/2700)
–65
65
200 MHz (PC3200)
–30
30
100/133/167 MHz
(PC1600/2100/2700)
–60
60
200 MHz (PC3200)
–40
40
–100
100
–75
75
100/133/167 MHz
(PC1600/2100/2700)
Half-period jitter, see Figure 8
Output clock slew rate, see Figure 9
Load: 120 Ω, 14 pF
t(φ)
Static phase offset, see Figure 5
100/133/167/200 MHz
Output skew, see Figure 6
Load: 120 Ω, 14 pF;
100/133/167/200 MHz
2
V/ns
ps
40
ps
VYx
R = 60 W
VDD/2
VYx
CDCVF855
GND
S0229-02
Submit Documentation Feedback
ps
50
VDD
Figure 1. IBIS Model Output Load
ps
1
Refers to the transition of the noninverting output.
This parameter is assured by design but cannot be 100% production tested.
R = 60 W
ps
–50
PARAMETER MEASUREMENT INFORMATION
6
UNIT
ns
tslr(o)
(1)
(2)
MAX
3.5
200 MHz (PC3200)
tsk(o)
TYP
Low- to high-level propagation delay
Test mode/CLK to any output
time
CDCVF855
www.ti.com
SCAS839A – APRIL 2007 – REVISED MAY 2007
PARAMETER MEASUREMENT INFORMATION (continued)
VDD/2
C = 14 pF
R = 10 W
Z = 60 W
Scope
–VDD/2
Z = 50 W
R = 50 W
V(TT)
Z = 60 W
R = 10 W
Z = 50 W
R = 50 W
C = 14 pF
V(TT)
CDCVF855
–VDD/2
–VDD/2
V(TT) = GND
S0230-02
Figure 2. Output Load Test Circuit
VDD
C = 14 pF
Probe
GND
Z = 60 W
C = 1 pF
R = 120 W
R = 1 MW
V(TT)
Z = 60 W
C = 14 pF
C = 1 pF
CDCVF855
V(TT)
GND
GND
R = 1 MW
V(TT) = GND
S0231-02
Figure 3. Output Load Test Circuit for Crossing Point
Yx, FBOUT
Yx, FBOUT
tc(n)
tc(n +1)
tjit(cc) = tc(n) – tc(n+1)
T0174-01
Figure 4. Cycle-to-Cycle Jitter
Submit Documentation Feedback
7
CDCVF855
www.ti.com
SCAS839A – APRIL 2007 – REVISED MAY 2007
PARAMETER MEASUREMENT INFORMATION (continued)
CLK
CLK
FBIN
FBIN
t(f)n
t(f)n+1
t(f) =
S
n=N
t(f)n
1
N
(N > 1000 Samples)
T0175-01
Figure 5. Phase Offset
Yx
Yx
Yx, FBOUT
Yx, FBOUT
tsk(o)
T0176-01
Figure 6. Output Skew
Yx, FBOUT
Yx, FBOUT
tc(n)
Yx, FBOUT
Yx, FBOUT
1
f0
tjit(per) = tc(n) –
1
f0
f0 = Average Input Frequency Measured at CLK/CLK
T0177-01
Figure 7. Period Jitter
8
Submit Documentation Feedback
CDCVF855
www.ti.com
SCAS839A – APRIL 2007 – REVISED MAY 2007
PARAMETER MEASUREMENT INFORMATION (continued)
Yx, FBOUT
Yx, FBOUT
t(hper_n)
t(hper_n+1)
1
f0
n = Any Half Cycle
1
2´f0
tjit(hper) = t(hper_n) –
f0 = Average Input Frequency Measured at CLK/CLK
T0178-01
Figure 8. Half-Period Jitter
VOH, VIH
80%
Clock Inputs
and Outputs
80%
20%
20%
VOL, VIL
tr
tslr(I/O) =
tf
V80% – V20%
tslf(I/O) =
tr
V80% – V20%
tf
T0179-01
Figure 9. Input and Output Slew Rates
(2)
Card
Via
Bead
0603
AVDD
VDDQ
4.7 mF
1206
0.1 mF
0603
GND
Card
Via
(1)
2200 pF
0603
PLL
AGND
S0232-01
(1)
Place the 2200-pF capacitor close to the PLL.
(2)
Recommended bead: Fair-Rite P/N 2506036017Y0 or equilvalent (0.8 Ω dc maximum, 600 Ω at 100 MHz).
NOTE: Use a wide trace for the PLL analog power and ground. Connect PLL and capacitors to AGND trace and connect
trace to one GND via (farthest from the PLL).
Figure 10. Recommended AVDD Filtering
Submit Documentation Feedback
9
PACKAGE OPTION ADDENDUM
www.ti.com
24-Jan-2013
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package Qty
Drawing
Eco Plan
Lead/Ball Finish
(2)
MSL Peak Temp
Op Temp (°C)
Top-Side Markings
(3)
(4)
CDCVF855PW
ACTIVE
TSSOP
PW
28
50
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CDCVF855
CDCVF855PWG4
ACTIVE
TSSOP
PW
28
50
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CDCVF855
CDCVF855PWR
ACTIVE
TSSOP
PW
28
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CDCVF855
CDCVF855PWRG4
ACTIVE
TSSOP
PW
28
2000
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CDCVF855
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4)
Only one of markings shown within the brackets will appear on the physical device.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 1
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
24-Jan-2013
Addendum-Page 2
PACKAGE MATERIALS INFORMATION
www.ti.com
24-Feb-2016
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
CDCVF855PWR
Package Package Pins
Type Drawing
TSSOP
PW
28
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
2000
330.0
16.4
Pack Materials-Page 1
6.9
B0
(mm)
K0
(mm)
P1
(mm)
W
Pin1
(mm) Quadrant
10.2
1.8
12.0
16.0
Q1
PACKAGE MATERIALS INFORMATION
www.ti.com
24-Feb-2016
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
CDCVF855PWR
TSSOP
PW
28
2000
367.0
367.0
38.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2016, Texas Instruments Incorporated
Similar pages