LinkCom DBFE-020U701-00 0-10v dimmable Datasheet

0-10V Dimmable
Constant Current Mode
25-DBFE Series
www.linkcom.com.tw For more information, please contact with: [email protected]
FEATURES:
● AC Input 108~305 Vac Nominal
● 1-10V Dimming
● AC Inrush current: 10 A @ 230 Vac Cold start
● Power Factor: > 0.95 @ 120 Vac / > 0.9 @ 277 Vac
● Protection: SCP / OVP / OCP
● High Operating Ambient Temp.: -30 ℃ ~ +60 ℃
● Surge Protection: L-N 2 kV
● Safety: Meets UL
● EMI: Meets FCC / Meets CE
● Comply with Indoor/Outdoor Waterproof (IP 67)
● Warranty: 5 years (refer to LinkCom warranty policy)
● RoHS Compliant
PRODUCT SPECIFICATION
DC OUTPUT
POWER(W)
DC OUTPUT
VOLTAGE(V)
OUTPUT
CURRENT(A)
OUTPUT
CURRENT
TOLERANCE
EFFICIENCY
O/P NOISE(P-P,V)
DBFE-025U701-00
26.6
30-38
0.7
±5%
84%
3
DBFE-020U701-00
19.6
20-28
0.7
±5%
84%
3
MODEL
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
108-305 Vac, 152-431 Vdc, Normal: 120-277 Vac
INPUT FREQUENCY
Range: 47-63 Hz, Normal: 50-60 Hz
ACTIVE POWER FACTOR
> 0.95 @ 120 Vac / > 0.9 @ 277 Vac
THD
< 20% @ 277 Vac at Full Load
TURN ON DELAY TIME
1s at Full Load 120 Vac / 277 Vac
AC CURRENT
0.35 A / 120 Vac 0.15 A / 277 Vac
INRUSH CURRENT (max)
Cold Start 10 A @ 230 Vac
LEAKAGE CURRENT
< 0.7 mA / 240 Vac
SHORT CIRCUIT PROTECTION
SCP will restart automatically after the fault condition is removed
OVER VOLTAGE PROTECTION
Shut down and latch off o/p voltage, re-power on to recover
OVER CURRENT PROTECTION
Constant Current
OPERATING TEMP.
-30℃~+60℃
STORAGE TEMP.
RELATIVE HUMIDITY
-40℃~+80℃
10% to +90%, non-cond.
SAFETY
Meets UL 60950-1
EMI
Meets FCC Part 15 / Meets EN 55015
WITHSTAND VOLTAGE
I/P-O/P: 3 kVac
ISOLATION RESISTANCE
I/P-O/P :10M Ω / 500 Vdc / 25℃ / 70% RH
DIMENSION (L*W*H)
134 * 42 * 33.1 mm【5.28 *1.65 * 1.3 inch】
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
*REFERENCE: www.linkcom.com.tw
*Please contact [email protected], [email protected] for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
Constant Current Mode
25-DBFE Series
www.linkcom.com.tw For more information, please contact with: [email protected]
DIMENSIONS
Tc Max.
LCCE-025U701 as Tc Max. Reference
*REFERENCE: www.linkcom.com.tw
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
Constant Current Mode
25-DBFE Series
www.linkcom.com.tw For more information, please contact with: [email protected]
DIMMING OPERATION
Parameters
Minimum
Absolute maximum voltageon on the 0-10(+) Purple Wire
Source current on the 0-10V(+) Purple Wire
Purple(+)
PDBFE0025■XXX-00G
Gray(-)
Typical
Maximum
1V
10V
0mA
100mA
(Leviton) IP710 Dimmer
V
(Lutron) NTSTV-DV Dimmer
Red(+)
Black(-)
Dimming Performance
110%
100%
Output Current (%)
90%
80%
70%
60%
50%
40%
30%
20%
Vin=120
10%
Vin=277
0%
0
1
2
3
4
5
6
7
8
9
10
Vdc
Notes:
1. Purple and Gray wires on the output side are used for 0-10V dimming.
2. When connected to different Dimmers, 0-10V dimmable version will have a ±10% output current tolerance.
3. Recommended dimmers are Leviton IP710,Lutron NTSTV-DV or equivalent.
4. When dimming wires +Purple/-Gray are left open, the output current will be at 100%.
5. If 0-10V Dimmer is below 1V, the LED Driver output will be shut down and enter to Hiccup mode.
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
Constant Current Mode
25-DBFE Series
www.linkcom.com.tw For more information, please contact with: [email protected]
Power Factor vs. Load (DBFE-025U701-00)
PF vs. Load
Power Factor
1.00
0.95
0.90
Vin=100
Vin=120
0.85
Vin=200
Vin=230
Vin=277
0.80
80%
85%
90%
95%
100%
105%
Load (%)
Efficiency vs. Load (DBFE-025U701-00)
Efficiency vs. Load
Efficiency (%)
90%
85%
80%
Vin=100
Vin=120
75%
Vin=200
Vin=230
Vin=277
70%
80%
85%
90%
95%
100%
105%
Load (%)
T.H.D vs. Load (DBFE-025U701-00)
THD vs. Load
30%
25%
THD (%)
20%
15%
Vin=100
10%
Vin=120
Vin=200
Vin=230
5%
Vin=277
0%
80%
85%
90%
95%
100%
105%
Load (%)
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
Constant Current Mode
25-DBFE Series
www.linkcom.com.tw For more information, please contact with: [email protected]
Output Current VS Load (DBFE-025U701-00)
Output Current vs. Load
Output Current (A)
0.720
0.710
0.700
Vin=100
Vin=120
0.690
Vin=200
Vin=230
Vin=277
0.680
80%
85%
90%
95%
100%
105%
Load (%)
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw