FF-1319A-13E This filter has been designed to operate with the Vicor "VI- HAMD / BAMD Harmonic Attenuator Modules" to meet EN55022, class B. This is a special model with a modified form factor, Raychem 44A0111 wire leads and a wide operating range from –40C to +65C. This model also has varistors inserted in order to suppress transients between line and neutral and also between the power leads and ground. Order P/N: FF-1319A-13E Operating Voltage = _________________DC to 270 Vac Operating Current (Max) = ________________ 13 Amps Operating Frequency = ___________________50/60 HZ Operating Temperature (Storage) = _______ -40 to 85°C Operating Temperature @ 13.0 A = _______ -40 to 65°C INSERTION LOSS vs. FREQUENCY Diel. Withstanding Voltage (Ph - Case) = ____ 1500 Vac Diel. Withstanding Voltage (Ph - Ph) = ______1500 Vdc Leakage Current @ 270 Vac, 60 HZ = _____2.7 mA Max Discharge Voltage after 60 sec = ___________34 V Max Transient Suppression = ______ turn on (382—466) Vdc Total Energy Absorption = 140 Joules / line (10x1000 us) Calculated MTBF = ________2,278,890 Hrs @ 30°C GB Wire # Ref 001 Line (L1) 002 Load 003 Neut (L2) 004 Load 005 Earth USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884 EUR JMK Inc Glasgow G13 1DN Scotland UK