Click on Series name for product info on aimtec.com Series AMER90C-CAZ up to 3.75A | AC-DC / DC-DC | LED Driver / Converter FEATURES: Models Single output • • • • • • • Constant current LED Driver or Converter Input range 90-305VAC/47-440Hz High Efficiency up to 91% 115VAC Operating temperature -50 to 85°C 230VAC Operating temperature -55 to 85°C Dimmable via resistive / 0-10Vdc / PWM 5 Years Limited Warranty Max Output Power (W)① Output Voltage Range (V)③ Output Current (A)③ Input Voltage (VAC/Hz) Input Voltage (VDC) AMER90C-50180CAZ 90 36-50 1.8 90-305/47440 130-430 AMER90C-36250CAZ 90 24-36 2.5 90-305/47440 130-430 AMER90C-24375CAZ 90 12-24 3.75 90-305/47440 130-430 Model • • • • • Over Temperature Protection Waterproof Case rated IP68 Power Factor Correction Short Circuit Protection Over Current Protection Mode of Operation Efficiency (%) 115 230 277 Constant Current ② Constant Voltage Constant Current 87 88 86 87 86 87 87 87 87 Constant Voltage Constant Current 88 87 87 86 86 86 Constant Voltage 87 86 86 VAC ② ② VAC VAC ① Exceeding the maximum output power will permanently damage the converter. ② The dimming feature is not supported when units are used in Constant Voltage mode only, ③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when ordering. NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-sale AMER90C-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. Input Specifications Parameters Current (full load) Inrush current <2ms(cold start) Leakage current Power factor External fuse Start-up time www.aimtec.com F 052.1e R3.B Conditions Typical 115 VAC 230 VAC 277 VAC 115 VAC 230 VAC 277 VAC I/O I/FG, O/FG 115 VAC 230 VAC 277 VAC Recommended slow blow type 0.98 0.94 0.90 2.5 1000 Tel: +1 514 620 2722 1 of 6 Maximum 1500 600 500 40 50 60 0.25 3.5 Units mA mA mA A A A mA mA A ms Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER90C-CAZ up to 3.75A | AC-DC / DC-DC | LED Driver / Converter Output Specifications Parameters Conditions Typical Maximum Units Conditions Typical Rated Units 500VDC >1000 Current accuracy ±3 % Line regulation (LL-HL) ±2 % Load regulation 0-100% load ±3 % Ripple & Noise* 150 mV p-p Hold-up time 100 ms Current adjustment range 100-10 % ④Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor. Isolation Specifications Parameters Tested voltage Isolation resistance I/O I/FG O/FG General Specifications Parameters Switching frequency Over current protection Over voltage protection Short circuit protection Short circuit restart Over temperature protection Operating temperature (See Derating Table) Cold Start-up Time Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting Wires Weight Dimensions (L X H X W) MTBF 3sec Conditions 3750 2000 500 VAC VAC VAC MΩ Typical Maximum 125 ≧105 ≧105 Continuous Auto recovery >105°C -50 to +85 -55 to +85 (115VAC) (230VAC) -55°C Units KHz % % o 35 100 C C Sec o C o C % / oC 95 % RH o -55 to +95 ±0.02 Free air convection Aluminum Epoxy (IP68 rated) UL1015 18AWG Input & 14AWG Output *20CM 900 7.13 x 2.32 x 1.85 inches 181.00 x 59.00 x 47.00 mm >400,000 hrs (MIL-HDBK-217F at +25°C) g Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052.1e R3.B CE EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13 Note: also designed to meet cULus, UL8750, UL60950-1 Tel: +1 514 620 2722 2 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER90C-CAZ up to 3.75A | AC-DC / DC-DC | LED Driver / Converter Dimensions Top View 181.00 (7.13) 4.00 (0.16) 41.00 (1.73) 27.00 (1.06) 8.00 (0.32) 11.00 (0.43) 23.00 (0.91) End View Side View 200.00 (8.00) 200.00 (8.00) 47.00 (1.85) 59.00 (2.32) 2.30 (0.09) Input/Output Wires are 18 AWG 20cm Measurements in Millimeters (inch) Case Tolerance: ±0.5 (±0.02) Temperature graph Free Air Convection 55 º C 100 80 Safe Operating Area 60 40 20 0 -40 -20 0 20 40 60 80 85 100 Ambient Temperature º C www.aimtec.com F 052.1e R3.B Tel: +1 514 620 2722 3 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER90C-CAZ Dimming Performance AMER90C-24375CAZ www.aimtec.com F 052.1e R3.B up to 3.75A | AC-DC / DC-DC | LED Driver / Converter Tel: +1 514 620 2722 4 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER90C-CAZ AMER90C-36250CAZ www.aimtec.com F 052.1e R3.B up to 3.75A | AC-DC / DC-DC | LED Driver / Converter Tel: +1 514 620 2722 5 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER90C-CAZ AMEPR90C-50180CAZ up to 3.75A | AC-DC / DC-DC | LED Driver / Converter NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.B Tel: +1 514 620 2722 6 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only