Lineage Power CPKW002A0C Power module; dc-dc converter 36-75 vdc input; 15.0vdc 2.0a output Datasheet

Data Sheet
October 2, 2009
CPKW002A0C1 Power Module; dc-dc Converter
36-75 Vdc Input; 15.0Vdc 2.0A Output
Features
ƒ
Compliant to RoHS EU Directive 2002/95/EC
(-Z versions)
ƒ
Delivers up to 30W of output power: 15V (2A)
ƒ
Small size: 33.0 mm x 24.0 mm x 8.5max mm
(1.30 x 0.945 x 0.335 in)
RoHS Compliant
Applications
ƒ
Through-hole (TH) mounting
ƒ
Sixteenth-Brick compatible footprint
ƒ
Cost efficient open frame design
ƒ
Single tightly regulated output
ƒ
Remote On/Off
ƒ
Output overcurrent protection
ƒ
Output overvoltage protection
ƒ
Distributed power architectures
ƒ
Over temperature protection
ƒ
Wireless Networks
ƒ
Output voltage adjustment trim -20% to +10%
ƒ
Access and Optical Network Equipment
ƒ
Wide operating temperature range (-40°C to +85°C)
ƒ
UL* 60950-1 Recognized, CSA† C22.2 No. 60950-103 Certified, and VDE‡ 0805 (IEC60950, 3rd Edition)
Licensed
ƒ
CE mark meets 2006/95/EC directives§
ƒ
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Options
ƒ
Remote On/Off logic (positive or negative)
Description
The CPKW002A0C1 power module is an isolated dc-dc converter that operates over a wide input voltage range of
36 to 75 Vdc and provides a single precisely regulated output. This module is a low cost, smaller size alternative to
the existing QW030C1. The output is fully isolated from the input, allowing versatile polarity configurations and
grounding connections. The module exhibit high efficiency, typical 90% for 15V at 2A. Built-in filtering for both input
and output minimizes the need for external filtering. These open frame modules are available in through-hole (TH)
form. Standard features include Remote On/Off, output voltage adjust, overvoltage, overcurrent and
overtemperature protection.
* UL is a registered trademark of Underwriters Laboratories, Inc.
†
‡
§
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
This product is intended for integration into end-use equipment. All of the required procedures of end-use equipment should be followed.
** ISO is a registered trademark of the International Organization of Standards
Document No: DS07-002 ver 1.03
PDF name: cpkw_ds.pdf
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Data Sheet
October 2, 2009
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
All
VIN
-0.3
80
Vdc
All
VIN, trans
-0.3
100
Vdc
All
TA
-40
90
°C
Storage Temperature
All
Tstg
-55
125
°C
I/O Isolation Voltage
All
⎯
⎯
500
Vdc
Input Voltage
Continuous
Transient (100ms)
Operating Ambient Temperature
(see Thermal Considerations section)
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
36
54
75
Vdc
Operating Input Voltage
All
VIN
Maximum Input Current
All
IIN,max
1.5
Adc
Inrush Transient
All
It
2
0.06
As
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN=0V to
75V, IO= IOmax ; see Figure 9)
All
30
mAp-p
Input Ripple Rejection (120Hz)
All
50
dB
(VIN=0V to 75V, IO=IO, max)
EMC, EN55022
2
See EMC Considerations section
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 3A (see Safety Considerations section). Based on the information
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating
can be used. Refer to the fuse manufacturer’s data sheet for further information.
2
LINEAGE POWER
Data Sheet
October 2, 2009
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Electrical Specifications (continued)
Parameter
Output Voltage Set-point
(VIN=VIN, nom IO=IO, max TA=25°C)
Device
Symbol
Min
Typ
Max
Unit
All
VO, set
-1.5
⎯
+1.5
% VO, nom
All
VO
-3.0
⎯
+3.0
% VO, nom
All
VO, adj
-20.0
+10.0
% VO, nom
Output Voltage
(Over all operating input voltage, resistive load,
and temperature conditions until end of life)
Adjustment Range
Selected by external resistor
Output Regulation
Line (VIN=VIN, min to VIN, max)
All
⎯
0.05
0.2
% VO, set
Load (IO=IO, min to IO, max)
All
⎯
0.05
0.2
% VO, set
Temperature (Tref=TA, min to TA, max)
All
⎯
⎯
1.00
% VO, set
15V
⎯
⎯
50
mVrms
⎯
⎯
150
mVpk-pk
Output Ripple and Noise on nominal output
Measured with 10uF Tantalum and 1uF ceramic
(VIN=VIN, nom IO=80% IO, max TA=25°C)
RMS (5Hz to 20MHz bandwidth)
Peak-to-Peak (5Hz to 20MHz bandwidth)
External Capacitance (min ESR = 10mΩ)
15V
CO, max
0
⎯
470
μF
Output Current
15V
Io
0
⎯
2.0
Adc
Output Current Limit Inception
15V
IO, lim
105
⎯
250
% IO, max
15V
IO, s/c
⎯
⎯
3.0
A rms
( Hiccup Mode )
Output Short-Circuit Current (RMS)
(VO≤250mV) ( Hiccup Mode )
LINEAGE POWER
3
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Data Sheet
October 2, 2009
Electrical Specifications (continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
VIN=VIN, nom, IO=80% IO, max, VO= VO, set ,TA=75°C
15V
η
88
90.0
⎯
%
VIN=VIN, nom, IO=50% IO, max, VO= VO, set ,TA=75°C
15V
η
86
88.0
⎯
%
Switching Frequency (Variable with Line & Load)
VIN=VIN, nom and IO= IO, max
All
fsw
⎯
250
⎯
kHz
VIN=VIN, nom and IO= 50% IO, max
All
fsw
⎯
420
⎯
kHz
Peak Deviation
15V
Vpk
⎯
1.0
⎯
% VO, set
Settling Time (Vo<10% peak deviation)
15V
ts
⎯
800
⎯
μs
Unit
Efficiency
Dynamic Load Response
(ΔIo/Δt=0.1A/μs, VIN=VIN, nom, TA=25°C)
Load Change from Io= 50% to 75% or 25% to
50% of Io,max:
Isolation Specifications
Parameter
Symbol
Min
Typ
Max
Isolation Capacitance
Ciso
⎯
33
⎯
nF
Isolation Resistance
Riso
10
⎯
⎯
MΩ
I/O Isolation Voltage
All
⎯
⎯
500
Vdc
General Specifications
Parameter
Min
Calculated MTBF (IO=80% of IO, max, TA=40°C, airflow=1m/s)
Telcordia SR-332 Issue 1: Method 1 Case 3
Weight
4
Typ
Max
6,206,856
⎯
11.6 (0.41)
Unit
Hours
⎯
g (oz.)
LINEAGE POWER
Data Sheet
October 2, 2009
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
All
Ion/off
⎯
⎯
1.0
mA
V
Remote On/Off Signal Interface
(VIN=VIN, min to VIN, max ; open collector or equivalent,
Signal referenced to VIN- terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low - Remote On/Off Current
Logic Low - On/Off Voltage
All
Von/off
-0.7
⎯
1.2
Logic High Voltage – (Typ = Open Collector)
All
Von/off
⎯
5.0
15
V
Logic High maximum allowable leakage current
All
Ion/off
⎯
⎯
50
μA
⎯
60
100
ms
⎯
60
100
ms
Turn-On Delay and Rise Times
(IO=80% of IO, max, TA=25°C)
Case 1: On/Off input is set ON and then input
power is applied (Tdelay = from instant at which
VIN=VIN, min until VO = 10% of VO, set).
Case 2: Input power is applied for at least 1
second and then On/Off input is set from OFF to
ON (Tdelay = from instant at which VIN=VIN, min until
VO = 10% of VO, set).
All
All
Tdelay
Case1
Tdelay
Case2
T rise = time for VO to rise from 10% of VO, set to
90% of VO, set.
All
Trise
⎯
0.2
1
ms
T rise = time for VO to rise from 10% of VO, set to
90% of VO, set with max ext capacitance
All
Trise
⎯
2.0
⎯
ms
15V
VO, limit
16.6
⎯
21.0
V
All
Tref
⎯
130
⎯
°C
V
Output Overvoltage Protection
Overtemperature Protection
(See Feature Descriptions)
Input Undervoltage Lockout
Turn-on Threshold
All
Vuv/on
⎯
32
35
Turn-off Threshold
All
Vuv/off
⎯
28
30
V
Hysterisis
All
Vhyst
⎯
4
⎯
V
LINEAGE POWER
5
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Data Sheet
October 2, 2009
Characteristic Curves
The following figures provide typical characteristics for the CPKW002A0C1 (15.0V, 2.0A) at 25°C.
OUTPUT CURRENT, Io (A)
95
EFFICIENCY, η (%)
90
Vin = 36V
85
Vin = 75V
80
Vin = 54V
75
70
0.0
0.5
1.0
1.5
2.0
O
OUTPUT CURRENT, IO (A)
TIME, t (500μs/div)
igure 5. Transient Response to Dynamic Load Change
from 50% to 75% to 50% of full load.
6
INPUT VOLTAGE
VIN (V) (20V/div)
VO (V) (5V/div)
TIME, t (10ms/div)
Figure 4. Typical Start-Up with application of Vin.
OUTPUT VOLTAGE
VO (V) (100mV/div)
IO (A) (0.5A/div)
OUTPUT CURRENT, OUTPUT VOLTAGE
Figure 3. Typical Output Ripple and Noise,
@ 80% Full Load.
OUTPUT VOLTAGE
TIME, t (1μs/div)
Figure 2. Derating Output Current versus Local
Ambient Temperature and Airflow
VO (V) (5V/div)
VO (V) (50mV/div)
OUTPUT VOLTAGE,
Figure 1. Converter Efficiency versus Output Current
AMBIENT TEMPERATURE, TA C
TIME, t (500μs/div)
Figure 6. Typical Output Rise Characteristic,
without external capacitance fitted.
LINEAGE POWER
Data Sheet
October 2, 2009
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Design Considerations
Test Configurations
CURRENT PROBE
TO OSCILLOSCOPE
The power module should be connected to a low
ac-impedance source. Highly inductive source
impedance can affect the stability of the power module.
For the test configuration in Figure 7 a 33μF electrolytic
capacitor (ESR<0.7Ω at 100kHz), mounted close to the
power module helps ensure the stability of the unit.
Consult the factory for further application guidelines.
LTEST
Vin+
BATTERY
12μH
CS
220μF
Input Source Impedance
33μF
E.S.R.<0.1Ω
@ 20°C 100kHz
Safety Considerations
Vin-
NOTE: Measure input reflected ripple current with a simulated
source inductance (LTEST) of 12μH. Capacitor CS offsets
possible battery impedance. Measure current as shown
above.
Figure 7. Input Reflected Ripple Current Test Setup
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standard,
i.e., UL 60950-1, CSA C22.2 No. 60950-1-03, and VDE
0805 (IEC60950, 3rd Edition).
The modules spacing (creepages and clearances) have
been designed to meet Functional Insulation.
COPPER STRIPS
Vout+
SCOPE
Vout-
1μF
RLOAD
10μF
NOTE: Use a 1μF ceramic capacitor and a 10μF aluminium or
tantalum capacitor. The scope measurement should be
made using a BNC socket. Position the load 50mm to
75mm (2" to 3") from the module.
If the input source is non-SELV (ELV or a hazardous
voltage greater than 60 Vdc and less than or equal to
75Vdc), for the module’s output to be considered as
meeting the requirements for safety extra-low voltage
(SELV), all of the following must be true:
•
The input source is to be provided with reinforced
insulation from any other hazardous voltages,
including the ac mains.
•
If the output pins are accessible to the end user,
then to maintain the output voltage to ground (earth)
within ELV or SELV limits, Vin(+) pin of the input
and Vout (-) pin of the output must be reliably
grounded (earthed) in the end application.
•
The input pins of the module are not operator
accessible.
•
Another SELV reliability test is conducted on the
whole system (combination of supply source and
subject module), as required by the safety agencies,
to verify that under a single fault, hazardous
voltages do not appear at the module’s output.
Figure 8. Output Ripple and Noise Test Setup
Rdistribution
Rcontact
Rcontact
Vin+
Vout+
RLOAD
VO
VIN
Rdistribution
Rcontact
Rcontact
Vin-
Rdistribution
Rdistribution
Vout-
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
The input to these units is to be provided with a
maximum 3A fast-acting fuse in the ungrounded lead.
Figure 9. Output Voltage and Efficiency Test Setup
⎡ VO × IO ⎤
Efficiency (η ) = ⎢
× 100 (% )
⎣VIN × IIN ⎥⎦
LINEAGE POWER
7
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Data Sheet
October 2, 2009
Feature Descriptions
Overcurrent Protection
To provide protection in a fault (output overload)
condition, the unit is equipped with internal
current-limiting circuitry and can endure current limiting
continuously. At the point of current-limit inception, the
unit enters hiccup mode. The unit operates normally
once the output current is brought back into its specified
range. The average output current during hiccup is 10%
IO, max.
Remote On/Off
Two remote on/off options are available. Positive logic
turns the module on during a logic high voltage on the
ON/OFF pin, and off during a logic low. Negative logic
remote On/Off, device code suffix “1”, turns the module
off during a logic high and on during a logic low.
To maintain compatibility with LW series power modules
the Remote On/Off pin is optional for the TH (through
hole) version. Standard TH modules have no On/Off pin
fitted. TH modules ordered with device code suffix “1”
are negative logic with the On/Off pin fitted.
Vin+
Vout+
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout
limit, the module operation is disabled. The module will
only begin to operate once the input voltage is raised
above the undervoltage lockout turn-on threshold,
VUV/ON.
Once operating, the module will continue to operate until
the input voltage is taken below the undervoltage turn-off
threshold, VUV/OFF.
Output Overvoltage Protection
The output overvoltage protection consists of circuitry
that internally clamps the output voltage. If a more
accurate output overvoltage protection scheme is
required then this should be implemented externally via
use of the remote on/off pin.
Overtemperature Protection
These modules feature an overtemperature protection
circuit to safeguard against thermal damage. The circuit
shuts down the module if the temperature measured at
the thermal reference point Tref exceeds maximum
limits. The module will automatically restart if the
temperature at Tref has reduced sufficiently. The
module can continue in this mode until the
overtemperature condition is cleared.
Ion/off
ON/OFF
TRIM
Von/off
Vin-
Vout-
Figure 10. Remote On/Off Implementation
To turn the power module on and off, the user must
supply a switch (open collector or equivalent) to control
the voltage (Von/off) between the ON/OFF terminal and
the VIN(-) terminal. Logic low is 0V ≤ Von/off ≤ 1.2V. The
maximum Ion/off during a logic low is 1mA, the switch
should be maintain a logic low level whilst sinking this
current.
During a logic high, the typical Von/off generated by the
module is 5.0V, and the maximum allowable leakage
current at Von/off = 5.0V is 50μA.
If not using the remote on/off feature:
For positive logic, leave the ON/OFF pin open.
For negative logic, short the ON/OFF pin to VIN(-).
8
LINEAGE POWER
Data Sheet
October 2, 2009
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Feature Descriptions (continued)
Output Voltage Set-Point Adjustment
(Optional pin on TH version)
Trimming allows the user to increase or decrease the
output voltage set point of the module. This is
accomplished by connecting an external resistor
between the TRIM pin and either the Vout+ pin or the
Vout- pin.
Vin+
Vout+
ON/OFF
RLOAD
TRIM
Radj-up
Vin-
Vout-
Trim Down – Decrease Output Voltage
By connecting an external resistor between the TRIM pin
and Vout+ pin (Radj-down), the output voltage set point
decreases (see figure 11). The following equation
determines the external resistor value to obtain an output
voltage change from Vo, nom to the desired Vo, adj:
Module
⎤
⎡ (Vo , adj − L) × G
Radj − down = ⎢
− H ⎥Ω
⎦
⎣ (Vo , nom − Vo , adj )
Radj-down
ON/OFF
Vin-
H
K
L
5110
12.5
2.5
Table 1 . Trim Constants CPKW002A0C1
The combination of the output voltage adjustment and
the output voltage initial tolerance must not exceed the
allowable trim range of 90% to 110% of the nominal
output voltage as measured between the Vout+ and
Vout- pins.
Vout+
TRIM
G
CPKW002A0C1 10,000
Note: Values for G, H, L and K are defined for each
module version in the following table 1 .
Vin+
Figure 12. Circuit Configuration to Increase Output
Voltage
RLOAD
Vout-
Figure 11. Circuit Configuration to Decrease Output
Voltage
Trim Up – Increase Output Voltage
By connecting an external resistor between the TRIM pin
and Vout- pin (Radj-up), the output voltage set point
increases (see figure 12). The following equation
determines the external resistor value to obtain an output
voltage change from Vo, nom to the desired Vo, adj:
The CPKW002A0C1 power modules have a fixed
current-limit set point. Therefore, as the output voltage
is adjusted down, the available output power is reduced.
Trim Examples
For CPKW002A0C1, nominal 15.0V module. To trim
module up to 15.5V (see figure 12):
⎡ (10,000 × 2.5)
⎤
− 5110⎥ Ω
Radj − up = ⎢
⎣ (15.5 − 2.5 − 12.5)
⎦
Radj − up = 44,890 Ω
⎡
⎤
(G × L)
− H ⎥Ω
Radj − up = ⎢
⎣ (Vo , adj − L − K )
⎦
Note: Values for G, H, L and K are defined for each
module version in the following table 1 .
LINEAGE POWER
9
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Feature Descriptions (continued)
Thermal Considerations
The power module operates in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation.
C3 = 220uF low impedance electrolytic
C4 = 1000nF low impedance SMT ceramic
C5 = 220nF low impedance SMT ceramic
L1 = Common Mode inductor, Pulse Engineering type
P0420 1.32mH.
L2 = 10uH differential inductor
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the
module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel.
Vi(+)
Vi(+)
C3
C1
The thermal reference point, Tref used in the
specifications is shown in Figure 13. For reliable
o
operation this temperature should not exceed 110 C.
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame BoardMounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
Data Sheet
October 2, 2009
Vi(-)
C4
DC/DC
C2
L1
Vo(+)
Vi(-)
Vo(-)
L2
C5
Figure 14. Suggested Configuration for EN55022
Class B
Tref
90
EN 55022 Class B Conducted AV (Mains Port)
80
70
EN 55022 Class A Conducted AV (Mains Ports)
60
EN 55022 Class B Conducted AV (Mains Ports)
50
Lev el (dB uV )
40
Figure 13. Tref Temperature Measurement
Location
30
20
10
150k
Frequency (Hz)
1M
10M
30M
Figure 15. EMC signature using above filter.
Heat Transfer via Convection
Increased airflow over the module enhances the heat
transfer via convection. Derating figures showing the
maximum output current that can be delivered by each
module versus local ambient temperature (TA) for natural
convection and up to 2m/s (400 ft./min) are shown in the
respective Characteristics Curves section.
EMC Considerations
The figure 14 shows a suggested configuration to meet
the conducted emission limits of EN55022 Class B in an
application that only requires 500Vdc operational
isolation between input and output.
Layout Considerations
The CPKW002A0C1 power module is a low profile in
order to be used in fine pitch system card architectures.
As such, component clearance between the bottom of
the power module and the mounting board is limited.
Avoid placing copper areas on the outer layer directly
underneath the power module. Also avoid placing via
interconnects underneath the power module.
For additional layout guide-lines, refer to FLTR100V10
data sheet.
Component Values:
C1, C2 = 1500nF low impedance SMT ceramic
10
LINEAGE POWER
Data Sheet
October 2, 2009
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Post Solder Cleaning and Drying
Considerations
Post solder cleaning is usually the final circuit-board
assembly process prior to electrical board testing. The
result of inadequate cleaning and drying can affect both
LINEAGE POWER
the reliability of a power module and the testability of the
finished circuit-board assembly. For guidance on
appropriate soldering, cleaning and drying procedures,
refer to Lineage Power Board Mounted Power Modules:
Soldering and Cleaning Application Note
(AP01-056EPS).
11
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Data Sheet
October 2, 2009
Mechanical Outline for CPKW002A0C1 Through-Hole Module
Dimensions are in millimeters and [inches].
Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated)
x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.]
33.0
[1.30]
12.0
[0.47]
24.0
[0.945]
Top View
8.5
[0.335]
MAX
2.54
[0.100]
16.0
[0.63]
Side View
0.635
[0.025]
Ø 0.95 MAX
[0.0375]
0.762
[0.030]
Function
1
Vin+
2
ON/OFF
3
Vin-
4
VO-
5
TRIM
6
VO+
12
7.62
[0.300]
Pin
15.24
[0.600]
Bottom View
4.4
[0.17]
Pin Cross Section
2.5
[0.10]
PIN3
PIN4
PIN2
PIN5
PIN1
PIN6
27.94
[1.100]
LINEAGE POWER
Data Sheet
October 2, 2009
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Recommended Pad Layout for Through-Hole Module
Dimensions are in millimeters and [inches].
Tolerances: x.x mm ± 0.5 mm [x.xx in. ± 0.02 in.] (Unless otherwise indicated)
x.xx mm ± 0.25 mm [x.xxx in ± 0.010 in.]
[1.30]
33.0
Pin
Function
1
Vin+
2
ON/OFF
3
Vin-
4
VO-
5
TRIM
6
VO+
24.0
[0.945]
15.24
[0.600]
7.62
[0.300]
2.5
[0.10]
27.94
[1.100]
PIN1
PIN6
PIN2
PIN5
PIN3
PIN4
IN 6 POSITIONS
RECOMMENDED HOLE Ø 1.2mm
RECOMMENDED PAD Ø 3.5mm
Through-Hole Pad Layout – Component side view
LINEAGE POWER
13
CPKW002A0C1 Power Module; dc-dc Converter
36 – 75 Vdc Input; 15Vdc 2A Output
Data Sheet
October 2, 2009
Ordering Information
Please contact your Lineage Power Sales Representative for pricing, availability and optional features.
Table 2. Device Codes
Input
Voltage
Output
Voltage
Output
Current
Connector
Type
TH
Product
codes
Comcodes
2.0A
Remote
On/Off Logic
Negative
48 Vdc
15.0V
CPKW002A0C1Z
CC109127602
48 Vdc
15.0V
2.0A
Negative
TH
CPKW002A0C81Z
CC109141066
Table 3. Device Options
Option
Suffix
Negative remote on/off logic
1
Pin Length: 2.79 mm ± 0.25 mm, (0.110 in. ± 0.010 in.)
8
RoHS Compliant (6 of 6)
Z
Asia-Pacific Headquarters
Tel: +65 6593 7211
World Wide Headquarters
Lineage Power Corporation
601 Shiloh Road, Plano, TX 75074, USA
+1-800-526-7819
(Outside U.S.A.: +1-972-244-9428)
www.lineagepower.com
e-mail: [email protected]
Europe, Middle-East and Africa Headquarters
Tel: +49 898 780 672 80
India Headquarters
Tel: +91 80 28411633
Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or
application. No rights under any patent accompany the sale of any such product(s) or information.
Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents.
© 2009 Lineage Power Corporation, (Plano, Texas) All International Rights Reserved.
Document No: DS07-002 ver. 1.03
PDF name: cpkw_ds.pdf