AIMTEC AM10EW-11012S-NZ 10 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM10EW-NZ
10 Watt | DC-DC Converter
FEATURES:
• Efficiency up to 86%
• Ultra Wide 4:1 input range
• Continuous Short Circuit Protection
• Operating temperature -40oC to + 85oC
Models
Single output
Model
AM10EW-11005S-NZ
AM10EW-11012S-NZ
AM10EW-11015S-NZ
AM10EW-11024S-NZ
Input Voltage
(V)
Input Specifications
Parameters
Voltage range
Filter
Input Surge Voltage (1sec max.)
Start-up Voltage
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short Circuit restart
Transient Recovery Time
Transient Deviation Response
Line voltage regulation
Load voltage regulation
Over Voltage Protection
Temperature coefficient
Ripple & Noise
www.aimtec.com
F 051e R12.B
40~160
40~160
40~160
40~160
Output Voltage
(V)
Output Current
max (mA)
5
12
15
24
2000
833
667
416
Nominal
Typical
110
Conditions
1 min
• Low ripple and noise
• Over Voltage Protection
● Input / Output Isolation 1500VDC
40~160
π (Pi) Network
Typical
Capacitive load
max (μF)
2200
220
100
47
25% Load Step
Change
Full Load (HL-LL)
5-100% load
20Mhz bandwidth
Typical
±1
Continuous
Auto Recovery
500
±3
±0.2
±0.5
120
±0.03
100
Tel: +1 514 620 2722
1 of 3
81
85
85
86
Maximum
Units
180
40
VDC
VDC
170
VDC
Rated
Units
VDC
MOhm
pF
Maximum
Units
1000
±5
±0.5
±1
140
µs
%
%
%
% Vo
%/oC
mV p-p
1500
> 1000
1000
Conditions
Efficiency
(%)
±2
%
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM10EW-NZ
10 Watt | DC-DC Converter
General Specifications
Parameters
Switching frequency
Operating temperature
Conditions
Storage temperature
Max case temperature
Cooling
Humidity
Maximum
350
-40 to +85
-55 to +125
Free air convection
Non condensing
1.5 mm from case 10
sec.
Solder Temp Leads
Case material
Weight
Dimensions (L x
MTBF
Typical
100% load
See derating chart
Units
KHz
o
C
o
C
o
C
105
95
%
o
300
C
Aluminum Alloy
22
g
Tolerance ±0.5mm
2.00 x 1.00 x 0.46 inches 50.80 x 25.40 x 11.80mm
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
W x H)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input
voltage and at rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency Approvals
Designed to meet IEC 60950 1:2001
Pin Out Specifications
Pin
Single
1
2
3
4
Vin Vin +
+Vout
-Vout
Dimensions
50.80
(2.00)
20.32
(0.80)
1
Bottom View
25.4
(1.00)
2
20.32
(0.80)
5.08
(0.20)
25.40
(1.00)
3
4
50.8
(2.00)
Built-in Stand-offs to
ease PCB cleaning
11.80
(0.47)
Notes:
All dimensions are typical
in millimeters (inches).
Tolerance ±0.25 (±0.01)
DIA
1.00
(0.04)
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM10EW-NZ
10 Watt | DC-DC Converter
Recommended Circuit
Vin+
Vin-
Vo+
Aimtec
DC/DC
Converter
C2
10µf
Load
C1
10 ~ 47µf
Vo-
Note: Greater noise filtering can be achieved with additional
capacitors, however the largest size can not exceed maximum
capacitive load specification.
Parallel connections are not recommended.
Product does not support hot swap / plug and play configurations.
Derating
Output Power ( % )
Free Air Convection
71ºC
100
80
Safe Operating Area
60
40
20
0
-40 -20 0 20 40 60 80 85 100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages