D100ED Series Very Low Cost, 1W SIP Dual Isolated Output DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Key Features: Parameter Conditions Min. Typ. Max. 5 VDC Input 4.5 5.0 5.5 12 VDC Input 10.8 12.0 13.2 24 VDC Input 21.6 24.0 26.4 • 1W Output Power • Miniature SIP Case Input Voltage Range • UL Approved (File E245422) • Dual Isolated Outputs • 1,000 VDC Isolation Input Filter Units VDC Internal Capacitor Reverse Polarity Input Current 0.3 A Typ. Max. Units ±3.0 ±3.0 % Output • >3.5 MHour MTBF Parameter • 12 Standard Models Output Voltage Accuracy • Industry Standard Pin-Out Line Regulation • LOWEST COST!! Conditions Min. For Vin Change of 1% ±1.2 Load Regulation Iout = 10% to 100% ±15.0 Ripple (20 MHz) See Note 2 Noise (20 MHz) See Note 2 Output Power Protection % 50 75 mV P - P 75 150 mV P - P ±0.03 %/ºC Max. Units 120 % Temperature Coefficient Output Short Circuit Momentary (0.5 Sec.) General RoHS Compliant Parameter Conditions Isolation Voltage, Input/Output Min. 1,000 VDC 1,000 VDC 500 VDC 1,000 Isolation Voltage, Output/Output Isolation Resistance Isolation Capacitance Typ. 60 Seconds 100 kHz, 1V Switching Frequency MΩ 60 pF 100 kHz Environmental Parameter Conditions Operating Temperature Range Ambient Storage Temperature Range Humidity Suite D Stoughton, MA 02072 USA Case Size T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Reliability Specifications Typ. Max. Units -40 +25 +85 ºC +125 ºC 95 % -55 Cooling MicroPower Direct Physical 292 Page Street Min. Free Air Convection RH, Non-condensing 0.77 x 0.24 x 0.39 Inches (19.6 x 6.0 x 10.0 mm) Case Material Non-Conductive Black Plastic (UL94-V0) Weight Parameter MTBF 0.07 Oz (2.1g) Conditions Min. MIL HDBK 217F, 25ºC, Gnd Benign Typ. Max. 3.5 Units MHours Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Conditions Min. Typ. Max. 5 VDC Input -0.7 9.0 12 VDC Input -0.7 18.0 24 VDC Input -0.7 30.0 Units VDC 1.5 mm From Case For 10 Sec 300 ºC All Models 450 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Input Model Number Voltage (VDC) Output 1 Current (mA) Output 2 Voltage Current Current Voltage Current Current Efficiency (%, Typ) Fuse Rating Slow-Blow (mA) Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (VDC) (mA, Max) (mA, Min) D101ED 5 4.5 - 5.5 285 30 5.0 100.0 10.0 5.0 100.0 10.0 70 500 D102ED 5 4.5 - 5.5 263 30 9.0 56.0 6.0 9.0 56.0 6.0 76 500 D103ED 5 4.5 - 5.5 259 30 12.0 42.0 4.2 12.0 42.0 4.2 77 500 D104ED 5 4.5 - 5.5 256 30 15.0 33.0 3.3 15.0 33.0 3.3 78 500 D111ED 12 10.8 - 13.2 115 12 5.0 100.0 10.0 5.0 100.0 10.0 72 250 D112ED 12 10.8 - 13.2 107 12 9.0 56.0 6.0 9.0 56.0 6.0 78 250 D113ED 12 10.8 - 13.2 107 12 12.0 42.0 4.2 12.0 42.0 4.2 78 250 D114ED 12 10.8 - 13.2 104 12 15.0 33.0 3.3 15.0 33.0 3.3 80 250 D121ED 24 21.6 - 26.4 58 7 5.0 100.0 10.0 5.0 100.0 10.0 71 125 D122ED 24 21.6 - 26.4 54 7 9.0 56.0 6.0 9.0 56.0 6.0 77 125 D123ED 24 21.6 - 26.4 55 7 12.0 42.0 4.2 12.0 42.0 4.2 76 125 D124ED 24 21.6 - 26.4 55 7 15.0 33.0 3.3 15.0 33.0 3.3 76 125 Notes: 1. Output load regulation is specified for a load change of 10% to 100%. 2. When measuring output ripple, it is recommended that an external ceramic capacitor (approx approx 1 µF to 10 µF) be placed from each output to common. 3. These units should not be operated with a load under 10% of full load. Operation at no-load may cause damage to the unit. 4. These converters are specified for operation without external components. However, in some applications the addition of input/ouput capacitors will enhance stability and reduce output ripple. Recommended capacitor values are: Vin 5 VDC 12 VDC 24 VDC Input Capacitor 4.7 µF 2.2 µF 1.0 µF Vout 5 VDC 9 VDC 12 VDC 15 VDC Block Diagram Output Capacitor 4.7 µF 2.2 µF 1.0 µF 0.47 µF For applications requiring very low output noise levels, a simple LC filter should be effective. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Derating g Curve Mechanical Dimensions Pin Connections Pin Function 1 2 4 5 6 7 +Vin -Vin -Vout 1 +Vout 1 -Vout 2 +Vout 2 Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is marked by a “dot” or indentation on the side of the unit MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]