Willow C60-X0 Optically isolated 0.5 to 2.5a Datasheet

Series C60
Optically Isolated 0.5 to 2.5A
Bi-Directional Solid-State Relay
Part Number
Relay Description
C60-X0
Solid-State Relay, Terminals for Through Hole Mount
SC60-X0
Solid-State Relay, Terminals for Surface Mount
Add suffix 01 to denote 60Sn/40Pb Pre-Tinned Leads
ELECTRICAL SPECIFICATIONS
(25°C UNLESS OTHERWISE SPECIFIED)
INPUT (CONTROL) SPECIFICATIONS (See Note 1)
Parameter
Min
Max
Units
Input Voltage Drop (See Figure 1)
1.1
1.5
Vdc
50
mA
Input Current (See Figure 1 and Notes 1, 7)
Input Current (Guaranteed On), (See Figure 4 and Note 7) 10
mA
Input Current (Guaranteed Off)
100
µA
Reverse Voltage Protection
-6
Vdc
OUTPUT (LOAD) SPECIFICATIONS (See Figure 2 And Note 2)
Part Number
Parameter
Output Voltage Rating
DC
Min Max
Min
Bi-Directional
Max
Units
C60-10
60
±60
Vdc
C60-20
100
±100
Vdc
C60-30
200
±200
Vdc
C60-40
400
±400
Vdc
C60-10
2.5
±1.25
Adc
C60-20
1.5
±0.75
Adc
C60-30
1.0
±0.50
Adc
C60-40
0.5
±0.25
Adc
On Resistance
C60-10
0.07
0.28
Ohm
(See Note 6)
C60-20
0.2
0.7
Ohm
C60-30
0.45
1.8
Ohm
C60-40
1.0
4.0
Ohm
Output Current Rating
Leakage Current at Rated Voltage
2.0
1.0
µAdc
Turn-On Time @ 10mA C60-10
4.0
4.0
ms
(See Figure 4 and Note 7)
C60-20,-30,-40
3.0
3.0
ms
Turn-Off Time
C60-10
4.0
4.0
ms
C60-20,-30,-40
3.0
3.0
ms
Output Capacitance
C60-10
1000
500
pf
C60-20
500
250
pf
C60-30
400
200
pf
C60-40
400
200
pf
Isolation (Input to Output)
109
Dielectric Strength
1500
109
3.0
Junction Temperature (TJ)
125
BLOCK DIAGRAM
Vrms
3.0
pF
125
°C
Junction to Case Thermal Resistance
25
°C
Case to Ambient Thermal Resistance
75
°C/W
© 2010 TELEDYNE RELAYS
DESCRIPTION
The Series C60 solid-state relay is
an advanced design capable of
switching very heavy loads in a
physically small 6-pin mini DIP
package. These relays have a
power FET output that ensures low
On resistance, no offset voltage
and low leakage current. They are
versatile and can be used to switch
AC, Bi-directional or DC loads.
Optical isolation ensures complete
protection of signal lines, power
and ground bus and control circuits
from switching noise and EMI.
Ohms
1500
Capacitance (Input to Output)
FEATURES/BENEFITS
• Power FET Output with Very
Low On Resistance: Virtually no
offset with very low leakage and
voltage drop.
• Optical Isolation: Isolates
control elements from load
transients. Eliminates ground
loops and signal ground noise.
• Three Terminal Output: Output
FETs can be paralleled
externally to change current
load rating.
• Floating Output: Allows for high
and low side switching.
• Switches High Voltages and
Currents: Voltages to 400 Vdc.
Current to 2.5 Adc.
Bi-directional, DC or AC.
• High Noise Immunity: Control
circuit cannot be triggered by
output switching noise.
• 6-Pin Mini-DIP Package:
Standard or surface mount
available.
(800) 284-7007 • www.teledynerelays.com
C60 1
2DSC60-X0 Rev --
Series C60
CHARACTERISTIC CURVES
MECHANICAL SPECIFICATION
WIRING CONFIGURATIONS
• Operating Temperature Range: -40°C to 85°C
• Storage Temperature Range: -40°C to 100°C
• Weight: 1 gm. maximum
• Case: 6 pin dual in line, filled epoxy
C60 2
NOTES:
1. Series resistor is required to limit input current to
50 mA maximum.
2. The input current is 10 mA for all tests unless
otherwise specified.
3. The surge current is non-repetitive for a
maximum duration of 20 ms (See Figure 3).
4. Loads may be connected to positive or negative
referenced power supplies. Inductive loads must
be diode suppressed.
5. Continuous load current is rated under the
conditions of still air and mounted on a printed
circuit board.
6. To calculate ON Resistance for a given junction
temperature calculate the new ROn using the
equation shown below:
ROn=R(25°C)x e0.006(TJ-25°C)
7. Turn on Time can be controlled with input control
current. Calculate a new turn-on time:
tOn=(tSpecification Limit)(10mA/IIn)
8. Load voltage rating should be derated 10% at
-40°C
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2010 TELEDYNE RELAYS
2DSC60-X0 Rev --